Entry  Thu Feb 27 16:30:57 2025, Konstantin und Rodolfo, DAQ, HF Signal 
We have exchanged the HF-Signal in the DAQ Electronic: from Dummy-HF to the real HF from accelerator. 
Entry  Thu Feb 27 21:23:02 2025, Jens, DAQ, Python Data Channels 
Python variables and names in DAQ
Because the Name of variables in DAQ doesnt match the the real variables, here is List of the channels and what value is in this channel
Entry  Fri Feb 28 00:44:31 2025, Denise, Sebastian, DAQ, Shutter auf - Shutter zu Go4 Signale Screenshot_2025-02-28-Shutter_auf-Shutter_zu.png
Shutter auf (TDC Kanal 12 / Go4 Kanal TrS11_Shutter auf)
Shutter zu (TDC Kanal 13 / Go4 Kanal TrS12_Shutter zu)
Entry  Fri Feb 28 17:36:15 2025, Konstantin, DAQ, Trigger events from accelarator 2025-02-28_17-34-15-990_1.png
We will use GENESIS to create trigger events (injection, ...) for the DAQ
Entry  Fri Feb 28 20:44:04 2025, Konstantin, DAQ, Updated Channel list 
Final (hopefully) channel list:

[TABLE border="1"]
Entry  Sat Mar 1 03:45:07 2025, Denise, Benedikt, Sebastian, DAQ, PH100 Gentecs @ Medusa 
Die zwei PH100 Messkoepfe am Nordwest und Suedwest Tower werden delayed in Medusa angezeigt und die Daten werden nicht an Medusa geschickt.

Letzteres haengt wohl mit den benoetigten 10 digits zusammen die MBS erwartet. 
Entry  Sat Mar 1 03:58:17 2025, Denise, Benedikt, Sebastian, DAQ, DAQ Daten xchecks 
Die allgemeinen DAQ Daten wurden ausfuehrlich crossgechecked und kommen nun alle an wie sie auch in die DAQ reinlaufen sollen.

Allerdings mussten die zwei PH100 Gentec Messkoepfe aus der DAQ gestrichen werden, da die Daten extrem verzoegert in die Slow Control Aufnahme reinlaufen.
Entry  Sat Mar 1 04:02:59 2025, Denise, Benedikt, Sebastian, DAQ, Lokale Datenaufnahme auf LXG1049 
Die Daten werden LOKAL auf dem LXG1049 unter folgendem Verzeichnis gespeichert:

[B]/data.local2/2025_krypton/[/B]
Entry  Sat Mar 1 04:10:48 2025, Denise, Benedikt, Sebastian, DAQ, DAQ Terminals 
Es gibt nun 3 Terminals am LXG1049 die immer offen sein sollten!

Entry  Sat Mar 1 07:01:41 2025, Denise, Benedikt, Sebastian, DAQ, UV Wellenlaenge in Python implementiert 
Die UV Wellenlaenge des WS7 wurde zusaetzlich zur WS7 Frequenz in Medusa hinzugefuegt um den korrekten Wellenlaengenscan des Pulssystems besser online zu
verfolgen.
Entry  Sat Mar 1 13:45:42 2025, Konstantin , DAQ, Gentec readout 
Gentec readout is now included in the general slow data acquisition. The issue was that the buffer of the power meter was not emptied fast enough. Now,
the data is read out permanently in a separate thread. 
Entry  Sat Mar 1 16:33:22 2025, Konstantin, DAQ, Restart of Go4  Screenshot_2025-03-01_16-34-01.pngScreenshot_2025-03-01_16-45-30.png
Restart of go4 before new scan:

1. Stop Acquisition (Stop button right next to the green play buttons)
Entry  Sat Mar 1 17:43:18 2025, Reinhold, Jens, Natalya, Danyal, Denise, Benedikt, DAQ, Scanbereich 257.175 nm - 257.675 nm 
[TABLE border="1"]
Zeit | Scanbereich (nm) | Anzahl Laserschritte | Start LMD | Stop LMD | Messdauer (s) | Elektronenkuehlung (s) | Kommentar
|-
Entry  Sat Mar 1 19:19:25 2025, Konstantin, DAQ, Offline Analysis Unbenanntes_Bild.pngg042.png
A copy of the current go4 analysis is placed at atplaser@lxgs1055:/kr_analysis. Use the usual Go4 startup routine to start an offline analysis of data.
They should be copied into the folder lxgs1055:/data.local2/E0075. To combine different 
lmd-files, simply create a file like "FirstScan.lml" containing the paths of the individual files. After this you can read the lml file with go4.
Entry  Sun Mar 2 03:07:43 2025, Denise, Benedikt, Danyal, DAQ, 0.0012 nm shifted scan: 257.1738 nm - 257.6754 nm 
[TABLE border="1"]
Zeit | Scanbereich (nm) | Anzahl Laserschritte | Start LMD | Stop LMD | Messdauer (s) | Elektronenkuehlung (s) | Kommentar
|-
Entry  Sun Mar 2 18:55:30 2025, Jens, Reinhold, Danyal, DAQ, Main Scan range (4 blocks) shifted by -0.0012 nm --> one more scan 
We decided to scan the main range, shifted by -0.0012nm, one more time in order to have the non-shifted AND the shifted range both 3x  ! 

[TABLE border="1"]
Entry  Sun Mar 2 23:05:16 2025, *Jens, Reinhold, Danyal, DAQ, extended normal scan range (no shift): 257.6750 - 257.8022 nm 
We will extend the max normal scan range by 3 measurements 

[TABLE border="1"]
Entry  Mon Mar 3 16:19:18 2025, Konstantin, DAQ, changed shutter timing - effective from 03.03.2025 @ 16:24 ! changed_shutter_timing.jpgchanged_shutter_timing_in_DAQ.jpg
The power and the fluctuations of the laser should be recorded in the XUV Data, so that the rate can be corrected. 
Therefore the shutter timing was changed. 
Entry  Mon Mar 3 20:14:10 2025, Jens, Konstantin, Reinhold, Danyal, DAQ, -0.0012 nm shifted whole range scan (@2nd ion energy) 

[TABLE border="1"]
Zeit | Scanbereich (nm) | Anzahl Laserschritte | Start LMD | Stop LMD | Messdauer (s) | Elektronenkuehlung (s) | Kommentar
Entry  Thu Feb 27 09:59:08 2025, Konstantin, Calibration, HV-Divider 
The readout of the HV divider runs on a RaspberryPi inside the HV-cave of the electron cooler.
Starting from 2025-02-27 09:42, the divider ratio was changed from 248517 to 248515. Usually, the
readout should run continuously. If not, the following procedure must be applied: