Fri Apr 4 17:13:12 2025, Team Pleiades, Detectors, PLEIADES detector out
|
17:12 We moved the PLEIADES detector out, both are outside now (in parking position) |
Fri Apr 4 17:10:35 2025, H. Weick, S. Litvinov, Accelerator, ESR scraper setting
|
the new scraper setting for good isochronicity but still acceptable intensity losses is:
Done at ~ 15:00 today.
GEEXDS1HA (outside) = -8 mm
|
Fri Apr 4 17:04:39 2025, H. Weick, S. Litvinov, Accelerator, slits after target, Bio_REM alarm
|
A Bio-REM detector on the roof of ESR caused an alarm and shut down the whole accelerator.
Too much primary beam going to ESR, noe we avoid it by catching the primary beam at TE4 slits.
The distribution on current grids looks liek in the LISE simulation, we cut at 5mm.
|
Fri Apr 4 16:59:25 2025, KK BJ, DAQ, Lassie screen shots  
|
|
Fri Apr 4 16:24:48 2025, Ruijiu, Yuri, Analysis, PID of 186Hf 7x
|
Code used to add up injection data.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/2025.04.04.13.00$ find /data.local/G22-00018_00203/results/analyzers/RSA01
-name "RSA01-2025.04.04.*.tiq_spectrogram.npz" > filelist.txt
|
Fri Apr 4 16:12:54 2025, JG, ID, General, pleiades detectors moving
|
We started moving the pleiades detectors at 16:13 04-04-2025.
We have the inside pocket (GE01DD2IG) at 2mm.
|
Fri Apr 4 16:12:14 2025, Team PLEIADES, Detectors, Inserting both PLEIADES detectors
|
We are inserting both PLEIADES detectors step-wise, one by one. Main beam should not be affected too long. |
Fri Apr 4 16:01:09 2025, ID, MC, Kanika, General, 186Hf running now + Lassie screenshots  
|
Tuning is finished, 186Hf is running. Sharp peaks now. |
Fri Apr 4 14:47:29 2025, ID MG BJ, General, Lassie screen shots  
|
186Hf screen shots with better resolution |
Fri Apr 4 14:01:20 2025, MG, ID,NH, General, Screen shot  
|
Lassie screen shots 186Hf |
Fri Apr 4 11:48:37 2025, MG, NH, ID, General, setting change to 186Hf + Lassie screenshots  
|
186Hf, 510MeV/u of 208Pb beam, ecooling not working |
Fri Apr 4 11:44:31 2025, Ragan, Wolfram, Sergey, Zsolt, Magda, General, ESR setting change from 188Hf72+ to 186Hf72+
|
ESR setting is changed from 188Hf72+ to 186Hf72+. SIS-18 beam energy for this fragment is 510 MeV/u.Brho = 7.86166 Tm. |
Fri Apr 4 11:00:35 2025, Ragan, Wolfram, Sergey, Zsolt, General, Electron Cooler
|
Electron cooler anode voltage needs a repair which might take 20-30 mins. If it takes longer, we'll proceed without a cooler curve measurement. |
Fri Apr 4 11:15:05 2025, Ragan, Wolfram, Sergey, Zsolt, General, Electron Cooler
|
No additional HV. So, have to proceed without the cooler.
Spare Power supply did not work either, we will not be able to use the cooler for the rest of the experiment |
Fri Apr 4 10:36:40 2025, Ragan, Wolfram, Sergey, Zsolt, General, ESR setting change from 188Hf72+ to 186Hf72+
|
ESR setting is changed from 188Hf72+ to 186Hf72+. SIS-18 beam energy for the primary beam transmission check is 528 MeV/u. |
Fri Apr 4 09:45:02 2025, Ragan, Wolfram, Sergey, General, Electron Cooler
|
Regina, Jan, and Markus are in the ESR to check the electron cooler. |
Fri Apr 4 09:26:11 2025, Nic, Magda, General, stop
|
STOP RSA for beam tuning |
Fri Apr 4 08:53:30 2025, Nic, Magda, Ragan, Jan, General, Beam Break   
|
Intensity dropped a lot, ion source fix ongoing
ESR access for 5-10 mins to restart PLEIADES DAQ
FRS has also taken beam again, so ESR is sharing
|
Fri Apr 4 07:51:58 2025, Nic, Magda, General, Screenshots    
|
|
Fri Apr 4 06:45:12 2025, zhang, zhou, General, screenshot    
|
|
Fri Apr 4 05:45:37 2025, zhang, zhou, General, screenshot    
|
|
|