HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018
  masses & isomeres 2025, Page 13 of 17  Not logged in ELOG logo
ID Date Author Category Subjectdown
  213   Sat Apr 5 20:11:57 2025 Xinliang Yan, Wenwen GeGeneralLassie Screenshot
  30   Tue Apr 1 06:31:46 2025 MichaelGeneralLassie Monitor 2025-04-01_06-31-10-211_tcl1064.png
  29   Tue Apr 1 05:58:51 2025 MichaelGeneralLassie Monitor 2025-04-01_05-58-09-122_tcl1064.png
  28   Tue Apr 1 05:29:45 2025 MichaelGeneralLassie Monitor 2025-04-01_05-29-01-845_tcl1064.png
  27   Tue Apr 1 04:59:14 2025 MichaelGeneralLassie Monitor 2025-04-01_04-58-31-351_tcl1064.png
  26   Tue Apr 1 04:27:10 2025 MichaelGeneralLassie Monitor 2025-04-01_04-25-53-171_tcl1064.png
  25   Tue Apr 1 03:55:59 2025 MichaelGeneralLassie Monitor 2025-04-01_03-55-21-183_tcl1064.png
  22   Tue Apr 1 03:27:44 2025 MichaelGeneralLassie Monitor 2025-04-01_03-22-05-395_tcl1064.png
  31   Tue Apr 1 06:53:51 2025 Jelena B,SiddharthGeneralLassie Monitor
  94   Wed Apr 2 21:22:41 2025 ID, HAGeneralLassie Come-Home Screenshots (wuff!)
(Who let the dog out?)
Sharing with FRS 6:1 since a while now.
  35   Tue Apr 1 11:47:14 2025 Jelena B, SiddharthGeneralLassie 2025-04-01_11-46-35-517_tcl1064.png
  32   Tue Apr 1 08:36:25 2025 Jelena B, SiddharthGeneralLassie 2025-04-01_08-37-32-155_tcl1064.png
  36   Tue Apr 1 12:58:27 2025 Jelena B, SiddharthGeneralLassie
  37   Tue Apr 1 14:02:23 2025 Jelena B, SiddharthGeneralLassie
  252   Sun Apr 6 23:51:33 2025 Siddharth, DimaSimulationsLISE file for the 192Pb setting
  20   Tue Apr 1 02:37:28 2025 H. Weick, S. LitvinovAcceleratorIsoc-setting +scrapers
First a setting with orbit bump for injection on central orbit was tried.
- quadrupoles tuned and scrapers optimized

Then back to an ESR setting without this bump like last year.
- again quadrupoles tuned and scrapers optimized
This gave a good resolution in which the isomer should be resolved.

Just after this was achieved all resolution was lost.
Making the input for ESR setting again recovered it, now with slightly different scrapers.

Quads: K'L Q3D / Q6D = -0.3603263
Sext: K''L GE01KS2 = -0.14
           GE01KS3 =  0.05

scrapers: GEEXDS1HA =  -5 mm
          GE01DS3HG = -70 mm 

Details see paper scans below.
  156   Fri Apr 4 16:12:14 2025 Team PLEIADESDetectorsInserting both PLEIADES detectors
We are inserting both PLEIADES detectors step-wise, one by one. Main beam should not be affected too long.
  15   Mon Mar 31 22:35:36 2025 ruijiu ChenAnalysisIdentification of 194Pb82
  129   Thu Apr 3 18:01:49 2025 Ruijiu, CarloAnalysisIdentification of 188Hf
  285   Mon Apr 7 17:51:15 2025 ShahabGeneralHowTo change resonance frequency of 410 MHz Cavity
step by step pictures:

sometimes the name of the motor connection is not available in the menu, it should be added manually.

Add MBOX:

put some name, like "410 MHz Schottky Cavity in ESR"
put the IP address: 140.181.139.194

press connect

change to local control

press initialize

go to motor drive

go to motor 1 and 2

always move same value for both motors.