HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018
  masses & isomeres 2025, Page 2 of 17  Not logged in ELOG logo
Entry  Thu Apr 3 23:42:05 2025, Zhang, Zhou, General, Screenshots 2025-04-03_23-38-53-553.png2025-04-03_23-39-23-636.png2025-04-03_23-39-40-886.png2025-04-03_23-39-47-569.png2025-04-03_23-43-29-862_tcl1064.tdf
 
Entry  Fri Apr 4 00:46:18 2025, Zhang, Zhou, General, Screenshots 2025-04-04_00-45-20-623.png2025-04-04_00-45-26-530.png2025-04-04_00-45-41-060.png2025-04-04_00-45-45-303.png2025-04-04_00-46-39-027_tcl1064.tdf
 
Entry  Fri Apr 4 01:41:48 2025, Zhang, Zhou, General, Screenshots 2025-04-04_01-40-34-575.png2025-04-04_01-40-42-763.png2025-04-04_01-40-16-954.png2025-04-04_01-40-23-181.png2025-04-04_01-41-03-078_tcl1064.tdf
 
Entry  Thu Apr 3 23:23:20 2025, Zhang Min, Zhou Xu, Accelerator, Beam injection change 2025-04-03_23-21-03-095.png
The SIS operator says that FRS doesn't need beam now, ESR will receive the full SIS beam extraction every 3 secs overnight. All the secondary beams are injected into ESR from now on.
Entry  Tue Apr 1 02:01:06 2025, Zac, Shahab, Ruijiu, Yuri, Sergey, Wolfram, Carlo, Michael, Accelerator, Settings lost 
Settings lost after the beam was lost. Trying to recover particle identification now that beam has returned.
Entry  Wed Apr 2 23:15:52 2025, Zac, Johan, Accelerator, No injections from SIS 
Night shift starts with no injections from SIS! We still have triggers; we called HKR and are waiting for response.
Entry  Wed Apr 2 23:27:35 2025, Zac, Johan, Accelerator, Beam is back 23:25 
 
Entry  Thu Apr 3 00:49:00 2025, Zac, Johan, General, Beam lost at 00:46 
 
Entry  Thu Apr 3 01:14:16 2025, Zac, Johan, General, Beam is back at 01:12 
 
Entry  Thu Apr 3 01:19:44 2025, Zac, Johan, General, Beam fluctuations 
Beam gone again between 01:14 and 01:18, then again at 01:19. HKR says there are problems with the source.
Entry  Thu Apr 3 01:29:49 2025, Zac, Johan, General, Beam is back at 01:27 
 
Entry  Thu Apr 3 01:56:57 2025, Zac, Johan, General, Problems with one of the quadrupoles 
Since around 01:45 we get spills but see nothing on analysers. HKR says there is a problem with one of the quadrupoles; they are working on it.
Entry  Thu Apr 3 02:01:29 2025, Zac, Johan, General, Quadrupole issues 
HKR has called someone to fix the quadrupole, they think it will take about an hour.
Entry  Thu Apr 3 02:52:27 2025, Zac, Johan, General, Beam is back at 02:52 
 
Entry  Thu Apr 3 05:11:37 2025, Zac, Johan, General, Beam lost at 05:07, returned at 05:14 
 
Entry  Thu Apr 3 06:33:08 2025, Zac, Johan, General, Beam lost at 06:27, returned at 06:34 
Spike in beam intensity at 06:27 (5x usual intensity) and then beam is lost. HKR says it's a problem with the magnet's power supply. Once the beam returned, the peaks are shifted to the left but are slowly shifting back into position.
Entry  Wed Apr 2 04:59:50 2025, Zac, Chris, Carlo, General, Receiving injections but not seeing anything on RSAs 2025-04-02_05-18-32-212_tcl1146.png2025-04-02_05-21-50-973_tcl1146.png
Starting at around 04:09 we don't see anything on RSAs. RSAs are still triggering and writing files, but only see noise. Lassie indicates beam current in the ESR

We called HKR, they said they will investigate, awaiting response.


last file that contains data: RSA01-2025.04.02.04.09.27.044.tiq_spectrogram.npz
file from which only noise is contained: RSA01-2025.04.02.04.09.31.905.tiq_spectrogram.npz 

At 04:09: drop of beam in the SIS as shown in screenshots.


For a minute there were still good data. Files from:
RSA01-2025.04.02.04.13.44.629.tiq_spectrogram.npz
to:
RSA01-2025.04.02.04.14.47.805.tiq_spectrogram.npz



05:30 update from HKR: There is a problem with the ESR main power supply. We have to wait.
Entry  Wed Apr 2 00:59:43 2025, Zac, Carlo, Chris, Accelerator, Lost the beam 
Beam was lost from 00:44 until 00:59
Entry  Fri Apr 4 17:59:33 2025, Zac , Sid, DAQ, 17:58 
DAQ stopped with last file in RSA1-2025.04.04.17.58.49.340.tiq

Now the plan is to change one of the analyzers to narrow band recording for longer from the 245 Schotkky. 
Entry  Tue Apr 1 15:32:59 2025, Zac, DAQ, NTCAP Restarted 
NTCAP Has been restarted (we restart every day around 15:00 so data goes in a new folder)
ELOG V3.1.5-fc6679b