  291   Mon Apr 7 19:41:31 2025 Oliver, FilipGeneralLassie screenshots
  290   Mon Apr 7 18:58:04 2025 ShahabDAQchanged averaging in NPZ files
new analysis settings for NPZ files:

[analysis]
nframes = 190
lframes = 65536
navg = 1


first file with this setting:

'RSA02-2025.04.07.18.57.17.454.tiq', 'RSA02-2025.04.07.18.57.02.328.tiq', 'RSA02-2025.04.07.18.58.17.958.tiq', 'RSA02-2025.04.07.18.57.40.143.tiq', 'RSA02-2025.04.07.18.58.25.520.tiq', 
'RSA02-2025.04.07.18.57.09.892.tiq', 'RSA02-2025.04.07.18.57.32.580.tiq', 'RSA02-2025.04.07.18.57.25.017.tiq', 'RSA02-2025.04.07.18.58.10.395.tiq', 'RSA02-2025.04.07.18.57.55.271.tiq', 
'RSA02-2025.04.07.18.56.54.765.tiq', 'RSA02-2025.04.07.18.58.02.833.tiq', 'RSA02-2025.04.07.18.57.47.707.tiq', 'RSA02-2025.04.07.18.56.47.202.tiq'
  289   Mon Apr 7 18:52:15 2025 Shahab, OliverDAQupdated DAQ settings
changed 410 resonance frequency back to plunger 8
245 MHz plunger stays at 350


center freq:
410 at 414.474 MHz
245 at 244.000 MHz

first good files in this setting are 18:51 onwards.

everything else remains same like last time.
  288   Mon Apr 7 18:42:17 2025 Oliver, FilipGeneralLassie screenshots
  287   Mon Apr 7 18:37:41 2025 Shahab, OliverDAQupdated DAQ settings
changed 410 resonance frequency back to 212th harmonic
plunger 33

center freq:

410,600 MHz

first good files in this setting are 18:36 onwards.

everything else remains same like last time.
  286   Mon Apr 7 18:17:41 2025 Shahab, OliverDAQupdated DAQ settings
changed 410 resonance frequency back to 213th harmonic
plunger 20

center freq:

412.537 MHz

first good files in this setting are 18:16 onwards.

everything else remains same like last time.
  285   Mon Apr 7 17:51:15 2025 ShahabGeneralHowTo change resonance frequency of 410 MHz Cavity
step by step pictures:

sometimes the name of the motor connection is not available in the menu, it should be added manually.

Add MBOX:

put some name, like "410 MHz Schottky Cavity in ESR"
put the IP address: 140.181.139.194

press connect

change to local control

press initialize

go to motor drive

go to motor 1 and 2

always move same value for both motors.
  284   Mon Apr 7 17:26:57 2025 Shahab, OliverDAQNew DAQ Settings
new DAQ Settings for the RSAs:

414475588 (192Pb+82   at 214 harmonic)
244.03689

plunger settings: 410 MHz cavity--> 8
245MHz cavity --> 350


recording at 50 MSPS
2^16 points each frame -->  1ms per frame

Average set to: 5 frames --> total of ca. 6.5 ms per average frame

first good NPZ file from this settings on RSAs starts from 17:41
  283   Mon Apr 7 17:25:00 2025 Oliver, FilipGeneralLassie screenshots
  282   Mon Apr 7 17:18:45 2025 Wolfram, Yuri, SergeyGeneralData from last 10 minutes are not useful (setting ESR)
  281   Mon Apr 7 17:07:33 2025 Team PLEIADESDetectorsMoving OUTSIDE PLEIADES detector slowly in (and out)
17:08 Tried to move outside particle detector (GE01DD2AG) in - it is stuck again :-(
17:18 Sergey tried to move it, now it moves again. Moved to -100 mm.
17:30 Moved detector to outside parking position
  279   Mon Apr 7 16:19:30 2025 Oliver, FilipGeneralLassie screenshots
  278   Mon Apr 7 16:11:44 2025 Ruijiu Chen, Yuri, Wolfram,AnalysisPID of 192Pb+82
  277   Mon Apr 7 16:07:42 2025 ShahabGeneralall config files
here are all TOML config files of the automatic scripts.
  276   Mon Apr 7 15:47:03 2025 Shahab, Taka, RuijiuDAQchange NAS and restart both acquisitions
changed storage place to bank 1 of the NAS
restarted the NTCAP with new address
restarted Analyzers with new address
restarted the queqiao script
restarted looper scripts

new files on RSAs start from:

2025-04-07 15:23 onwards

new files on NTCAP have their corresponding time stamp on the directory
  275   Mon Apr 7 15:23:01 2025 Ragan, Wolfram, Sergey, Zsolt, Yuri, Rui-JiuGeneralESR Setting change to 192Pb82+
Today, until 11 am, data were taken for the 188Hf setting. Since then, we are now tuning on the 192Pb82+.
  274   Mon Apr 7 15:14:54 2025 Oliver, FilipGenerallassie screenshots
  273   Mon Apr 7 14:05:40 2025 Jelena, GuyGeneralLassie screenshots
  272   Mon Apr 7 13:18:27 2025 Jelena, GuyGeneralTuning
Beam was gone at 13:04 due to fragment tuning.
  271   Mon Apr 7 12:29:16 2025 Jelena, GuyGeneralLassie screenshots