ID |
Date |
Author |
Category |
Subject |
120
|
Thu Apr 3 13:32:42 2025 |
CN, ID | General | Screenshots |
|
Attachment 1: 2025-04-03_13-31-16-104.png
|
|
Attachment 2: 2025-04-03_13-31-21-711.png
|
|
Attachment 3: 2025-04-03_13-31-42-214.png
|
|
119
|
Thu Apr 3 11:51:00 2025 |
CN, ID | DAQ | RSA started for 188Hf ESR tuning |
Started both RSAs for the tuning of the ESR to 188Hf. Both pockets are in parking position OUTSIDE. |
118
|
Thu Apr 3 10:07:34 2025 |
CN, ZP, CJG, MC | General | Screenshots |
|
Attachment 1: 2025-04-03_10-04-14-352.png
|
|
Attachment 2: 2025-04-03_10-04-23-381.png
|
|
Attachment 3: 2025-04-03_10-05-06-655.png
|
|
117
|
Thu Apr 3 09:53:02 2025 |
Ruijiu Chen,Wolfram | Analysis | Good injection ratio |
Currently, we only use 37% of the injections in our data analysis. However, 63% of the injections have a height below 100, and these may include
single ion injections. We need to visually inspect these injections to identify the single ion injections. |
Attachment 1: photo_2025-04-03_09-53-26.jpg
|
|
116
|
Thu Apr 3 09:43:14 2025 |
All | Accelerator | Stop 194Pb, switch to 208Pb82+ |
The repair of SIS electron cooler power supplies
In the meantime we received a few injections and confirmed that 194Pb setting is still as it was before entering into the ESR
Now we change to 208Pb82+ to do several ESR accelerator tests
Esis = 517 MeV/u
Change the beamline to 208 Pb 82+ and the ESR to 208 b 82+ and NO other changes |
115
|
Thu Apr 3 09:34:42 2025 |
ID | General | Finished in the ESR as of 9:05 |
We had stopped the RSAs at 8:00 (call for restart)
Time stamp computer stopped and started at 9:35 |
114
|
Thu Apr 3 08:02:04 2025 |
Team PLEIADES (JG, ID, CJG, MC) | Detectors | Entering ESR for PLEIADES |
We are going to enter the ESR to check on the PLEIADES pocket detectors and install a nitrogen cooling. |
113
|
Thu Apr 3 07:59:09 2025 |
ZP, CN, ID | General | Screenshots |
Screenshots before opening ESR. |
Attachment 1: 2025-04-03_07-58-00-874.png
|
|
Attachment 2: 2025-04-03_07-57-08-478.png
|
|
Attachment 3: 2025-04-03_07-57-36-781.png
|
|
112
|
Thu Apr 3 06:56:31 2025 |
JEL, ZN | Runs | Screenshots |
|
Attachment 1: 2025-04-03_06-55-08-030.png
|
|
Attachment 2: 2025-04-03_06-54-58-081.png
|
|
Attachment 3: 2025-04-03_06-55-25-792.png
|
|
111
|
Thu Apr 3 06:33:08 2025 |
Zac, Johan | General | Beam lost at 06:27, returned at 06:34 |
Spike in beam intensity at 06:27 (5x usual intensity) and then beam is lost. HKR says it's a problem with the magnet's power supply. Once the beam returned, the peaks are shifted to the left but are slowly shifting back into position. |
110
|
Thu Apr 3 06:16:32 2025 |
JEL, ZN | General | Screenshots |
Stable since last entry |
Attachment 1: 2025-04-03_06-15-12-250.png
|
|
Attachment 2: 2025-04-03_06-15-00-458.png
|
|
Attachment 3: 2025-04-03_06-14-54-153.png
|
|
109
|
Thu Apr 3 05:11:37 2025 |
Zac, Johan | General | Beam lost at 05:07, returned at 05:14 |
|
108
|
Thu Apr 3 03:48:40 2025 |
JEL, ZN | Runs | Screenshots |
The peaks in the analyzer are slowly shifting back to the original position.
Note that a quadrupole was the cause of the issue 45 mins ago and it was cycled. Might be relevant... |
Attachment 1: 2025-04-03_03-47-28-530.png
|
|
Attachment 2: 2025-04-03_03-47-11-337.png
|
|
Attachment 3: 2025-04-03_03-47-42-665.png
|
|
107
|
Thu Apr 3 02:59:15 2025 |
JEL, ZN | Runs | Screenshot, beam received, baem lost, beam back again |
Beam is back for 10 mins-
The peaks on the analyzer appear shifted to the right.
As I write this the beam disappeared again.... 02.59
and back again at 03.08 |
Attachment 1: 2025-04-03_02-58-06-109.png
|
|
Attachment 2: 2025-04-03_02-57-54-019.png
|
|
Attachment 3: 2025-04-03_02-57-31-430.png
|
|
106
|
Thu Apr 3 02:52:27 2025 |
Zac, Johan | General | Beam is back at 02:52 |
|
105
|
Thu Apr 3 02:01:29 2025 |
Zac, Johan | General | Quadrupole issues |
HKR has called someone to fix the quadrupole, they think it will take about an hour. |
104
|
Thu Apr 3 01:56:57 2025 |
Zac, Johan | General | Problems with one of the quadrupoles |
Since around 01:45 we get spills but see nothing on analysers. HKR says there is a problem with one of the quadrupoles; they are working on it. |
103
|
Thu Apr 3 01:29:49 2025 |
Zac, Johan | General | Beam is back at 01:27 |
|
102
|
Thu Apr 3 01:19:44 2025 |
Zac, Johan | General | Beam fluctuations |
Beam gone again between 01:14 and 01:18, then again at 01:19. HKR says there are problems with the source. |
101
|
Thu Apr 3 01:14:16 2025 |
Zac, Johan | General | Beam is back at 01:12 |
|