100
|
Thu Apr 3 00:49:00 2025 |
Zac, Johan | General | Beam lost at 00:46 |
|
99
|
Wed Apr 2 23:40:23 2025 |
JEL, ZN | General | Screenshots taken just as beam came back |
We are seeing spills being received but no peaks are seen in the analyzers.
We are seeing several intermittent losses of beam. Awaiting action to see if it stabilizes.
23.51 Beam is back and we see the nice spectrum in the analyzer. |
Attachment 1: 2025-04-02_23-39-29-655.png
|
|
Attachment 2: 2025-04-02_23-37-10-651.png
|
|
Attachment 3: 2025-04-02_23-36-58-664.png
|
|
98
|
Wed Apr 2 23:33:43 2025 |
Zac | Accelerator | Beam is gone at 23:29 |
|
97
|
Wed Apr 2 23:27:35 2025 |
Zac, Johan | Accelerator | Beam is back 23:25 |
|
96
|
Wed Apr 2 23:15:52 2025 |
Zac, Johan | Accelerator | No injections from SIS |
Night shift starts with no injections from SIS! We still have triggers; we called HKR and are waiting for response. |
95
|
Wed Apr 2 22:47:25 2025 |
ID, HA (Radio Shahab as background) | General | Lassie and Schottky TV screentshots |
We managed to take some screenshots while Shahab harrassed us with AI-created "RammstAIn" music... happy to end my shift now! |
Attachment 1: 2025-04-02_22-44-18-420.png
|
|
Attachment 2: 2025-04-02_22-45-12-849.png
|
|
Attachment 3: 2025-04-02_22-55-14-900.png
|
|
94
|
Wed Apr 2 21:22:41 2025 |
ID, HA | General | Lassie Come-Home Screenshots (wuff!) |
(Who let the dog out?)
Sharing with FRS 6:1 since a while now. |
Attachment 1: 2025-04-02_21-25-00-716.png
|
|
Attachment 2: 2025-04-02_21-25-42-535.png
|
|
Attachment 3: 2025-04-02_21-26-12-022.png
|
|
93
|
Wed Apr 2 20:57:34 2025 |
Shahab | Detectors | 10GB cables for the DAQ rack |
We have been working together with IT on the speed of data transfer: with the new 10 GB interface we can now transfer data from NAS to Lustre with 400MB/s. From NAS to GPU Computer up to 700MB/s. All cables around the rack are now 10GB capable. |
92
|
Wed Apr 2 20:15:29 2025 |
ID, HA | General | Lassie screenshots + Schottky TV |
Screeeeeeeenshooooots! |
Attachment 1: 2025-04-02_20-15-48-827_tcl1064.png
|
|
Attachment 2: 2025-04-02_20-17-14-017.png
|
|
Attachment 3: 2025-04-02_20-18-29-150.png
|
|
91
|
Wed Apr 2 19:13:50 2025 |
ID, HA | General | Lassie screenshots and Schottky screenshot |
Looks a bit more regular now (FRS people having dinner???) |
Attachment 1: 2025-04-02_19-10-29-388_tcl1064.png
|
|
Attachment 2: 2025-04-02_19-14-53-428_tcl1146.png
|
|
Attachment 3: 2025-04-02_19-19-23-765.png
|
|
90
|
Wed Apr 2 18:31:52 2025 |
ID | General | FYI for morning shifts Thu |
The PLEIADES team (pocket detectors) has discussed with Wolfram to get access to the ESR tomorrow (Thu) morning ~8:00 to check their detectors and install a dry N2 flow connection. This might take about 1h. Iris (or Jan) will call the HKR to get the RP shift for the transport of the N2 bottle into the ESR. Morning shift will be informed accordingly when we are onsite, just keep running (keep running...keep running...keep running) until we get access. |
89
|
Wed Apr 2 18:22:30 2025 |
ID | General | Spill cycle distribution |
The spill cycle distributions is absolutely nuts since beginning of the shift. On the positive side: we got a lot of spills since FRS did not take many, so I think we got more than our parasitic 1:10 share... |
88
|
Wed Apr 2 18:15:06 2025 |
ID, HA, MW | General | Lassie screenshots |
|
Attachment 1: 2025-04-02_18-14-21-624.png
|
|
87
|
Wed Apr 2 18:13:20 2025 |
ID, HA | General | RSA spectra |
|
Attachment 1: IMG_0087.jpeg
|
|
86
|
Wed Apr 2 17:46:12 2025 |
Ruijiu, Wolfram, Xinliang, Wangqian | Analysis | The spectrum of 194Pb82+ vs 184Pt78+ |
In summary, the statistical results collected between 5:00 and 12:00 AM on April 2, 2025. For each injection, we calculate the frequency mean value
(f_mean) and the peak height (P) of 194Pb ions for frames with t > 0.14 s, correct each injection’s frequency by subtracting f_mean, and only sum
the
spectra from injections with P > 100; moreover, by comparing the 194Pb82+ spectrum with that of 184Pt78+—whose isomer at 1.8 MeV (T1/2 = 1 ms) is
clearly visible—the setup is demonstrated to be suitable for detecting an isomer with a lifetime of about 1 ms.
===================================================================
How to dod analysis and plot this result:
1. Add up injections and create accumulated spectrum.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data$ sh generate_data.sh /data.local/G22-
00018_00203/results/analyzers/RSA01 RSA01-
'*.tiq_spectrogram.npz' 2025.04.02.05.00.00.000 2025.04.02.12.00.00.000 0.001 408.59e6 408.62e6 0.1 1
After run this command, you will create the accumulated spectrum under the folder with time stamp of start time and stop time.
2. Download the code "plot_fft.cxx" and plot the spectrum with following command:
...2025.04.02.05.00.00.000_2025.04.02.12.00.00.000$ root
------------------------------------------------------------------
| Welcome to ROOT 6.32.10 https://root.cern |
| (c) 1995-2024, The ROOT Team; conception: R. Brun, F. Rademakers |
| Built for linuxx8664gcc on Feb 12 2025, 01:50:41 |
| From tags/6-32-10@6-32-10 |
| With |
| Try '.help'/'.?', '.demo', '.license', '.credits', '.quit'/'.q' |
------------------------------------------------------------------
root [0] .L plot_fft.cxx
root [1] plot_fft("2025.4.2 5:00~12:00",411.14e6,411.18e6,0,100) |
Attachment 1: photo_2025-04-02_17-47-24.jpg
|
|
Attachment 2: plot_fft.cxx
|
// plot_fft.C
// This macro opens the ROOT file "combine_injection.root", retrieves the TH2D histogram
// named "FFT_accumulated", and draws it on a canvas with a logarithmic Z-axis.
// The canvas size is set to 800 x 1000, with the top margin set to 0.05 and the right margin increased.
// Additionally, the histogram title and statistics box are removed.
// You can specify the frequency (x-axis) and time (y-axis) ranges via the function parameters.
void plot_fft(const char* canvasTitle = "FFT Accumulated",double x_min = 0, double x_max = 0, double y_min = 0, double y_max = 0) {
// Open the ROOT file
TFile* file = TFile::Open("combine_injection.root");
if (!file || file->IsZombie()) {
std::cerr << "Error: Unable to open file combine_injection.root" << std::endl;
return;
}
// Retrieve the TH2D histogram named "FFT_accumulated"
TH2D* hist = dynamic_cast<TH2D*>(file->Get("FFT_accumulated"));
if (!hist) {
std::cerr << "Error: Histogram 'FFT_accumulated' not found in the file" << std::endl;
file->Close();
return;
}
// Remove the histogram title
hist->SetTitle("");
// Remove the statistics box
gStyle->SetOptStat(0);
// If valid ranges are provided (non-zero and x_min < x_max, etc.), apply them to the axes
if (x_max > x_min) {
hist->GetXaxis()->SetRangeUser(x_min, x_max);
}
if (y_max > y_min) {
hist->GetYaxis()->SetRangeUser(y_min, y_max);
}
// Create a canvas with size 800 x 1000
TCanvas* canvas = new TCanvas("canvas", canvasTitle, 800, 1000);
// Adjust canvas margins: top margin 0.05, increased right margin (e.g., 0.15)
canvas->SetTopMargin(0.05);
canvas->SetLeftMargin(0.12);
canvas->SetRightMargin(0.15);
// Set axis titles (if desired, you can modify these)
hist->GetXaxis()->SetTitle("Frequency [Hz]");
hist->GetYaxis()->SetTitle("Time [s]");
hist->GetZaxis()->SetTitle("Amplitude (arbitrary units)");
hist->GetZaxis()->SetTitleOffset(1.2);
// Set log scale for the Z-axis (color scale)
canvas->SetLogz();
// Draw the histogram using the "COLZ" option to display a color palette
hist->Draw("COLZ");
// Update the canvas to show the plot
canvas->Update();
// Add the canvas title at the top using TLatex
TLatex latex;
latex.SetNDC(); // Use normalized coordinates
latex.SetTextAlign(22); // Center alignment
latex.SetTextSize(0.04); // Adjust text size as needed
// Draw the title at (x=0.5, y=0.95) in normalized device coordinates
latex.DrawLatex(0.5, 0.98, canvasTitle);
// Optionally, you can save the canvas as an image file (e.g., PNG)
// canvas->SaveAs("FFT_accumulated.png");
}
|
Attachment 3: Screenshot_2025-04-02_22-00-57_1.png
|
|
85
|
Wed Apr 2 17:06:45 2025 |
ID, HA et al | General | Lassie screenshots |
|
Attachment 1: 2025-04-02_17-09-17-201.png
|
|
84
|
Wed Apr 2 16:28:14 2025 |
SS, ID, HA etc | DAQ | NTCAP stop/start |
NTCAP was stopped and restarted. |
83
|
Wed Apr 2 15:46:24 2025 |
ID, HA,MW | General | Beam back in ESR, |
beam is back, we started DAQ again. All files created after 15:45 should be good from now on. |
Attachment 1: 20250402_154135.jpg
|
|
82
|
Wed Apr 2 15:07:52 2025 |
Michael, Alex, Maeve | Accelerator | Still not a good beam in the ESR |
The (power supply of) SIS kicker magnet has been repaired and the beam has been restored from about 14:20.
But, the Schottky spectrum in the ESR looked pretty bad, so the measurement can not be restarted.
The accelerator experts are currently looking into this problem. |
81
|
Wed Apr 2 13:35:17 2025 |
Michael, Alex, Maeve | DAQ | RSAs data taking |
Since there will be no beam for about one hour, the data taking in RSAs has been stopped. |