Entry  Wed Apr 9 09:30:14 2025, Yuri, General, Slit changing 
I would like to close E01 slits a bit more and get 30 min of data with higher 
resolving power.

EEX scraper from -10 now -1
E01 unchanged
Entry  Thu Mar 27 09:42:04 2025, Ruijiu Chen, Simulations, Simulation Results for 194Pb and 188Hf 9x
Summary:

1.Simulated spectra for 194Pb and 188Hf.
2.The results are attached.
3. For the 188Hf simulation, some nuclides in the fragments are missing from the AME database, causing errors in the LiseReader program.
To fix this, please download the attached reader.py file and replace your local file at lisereader-main\lisereader\reader.py.
After replacing the file, recompile the program. Once recompiled, you should be able to simulate the 188Hf spectrum without issues.
Entry  Mon Apr 7 11:18:03 2025, Ruijiu Chen, Analysis, Simulation Results for 192Pb photo_2025-04-07_11-18-30.jpgexercise_192Pb_Expsimulation_result_192Pb.out
 
Entry  Tue Apr 8 12:08:56 2025, siddharth, Analysis, Sigma vs Mean Freq. Plot for 188Hf72+ setting 2 sigmaVsFreq_For188Hfsetting2.pngScreenshot_from_2025-04-08_12-20-38.png
This is sigma vs Freq plot for 188Hf72+ made out of 1hr of injections post Saturday, April 5th. 
The 2nd photo Compares the resolution of 188Hf setting by looking at peaks of 205Au and 205Pb which are very close in frequency range. The resolution in the second 188Hf72+ setting(on Right) seems much better as two peaks can be seen clearly. 
Entry  Fri Apr 4 17:30:25 2025, siddharth, Analysis, Sigma vs Mean Freq. Plot for 188Hf72+ setting sigmaVsFreq_For188Hfsetting.png
 
Entry  Mon Apr 7 11:26:52 2025, siddharth, Analysis, Sigma vs Mean Freq. Plot for 186Hf setting sigmaVsFreq_For186Hfsetting.pngsigmaVsFreq_For186Hfsetting2.png
1st plot is of Sigma vs Freq for 186Hf72+ setting. The green vertical line is at 411.843MHz.
2nd plot is of Sigma vs Freq for 186Hf72+ setting from april 4th 20:00 to April 5th 09:00 with time cut 0.14, shift tracking applied and pwr-limit 100. About 5200 Injections.
Entry  Mon Apr 7 11:35:23 2025, siddharth, Analysis, Sigma vs Mean Freq. Plot for 186Hf setting sigmaVsFreq_For186Hfsetting.pngsigmaVsFreq_For186Hfsetting2.png
1st plot is of Sigma vs Freq for 186Hf72+ setting. The green vertical line is at 411.843MHz.
2nd plot is of Sigma vs Freq for 186Hf72+ setting from April 4th 20:00 to April 5th 09:00 with time cut 0.14, shift tracking applied and pwr limit 100, about 5200 injections.( the green vertical line is at 411.843 and not at 411.7) 
Entry  Thu Mar 27 17:20:40 2025, Esther, Yue, Carlo, Zac, Shahab, Detectors, Setup Genesys 2025-03-27_17-19-33-724.png
We set up the Genesys. Channel map:

tr0:
IO1: Trigger MBS
IO2: Trigger NTCAP
IO3: None
IO4: Trigger RSA01
IO5: Trigger RSA02

tr1: 
None
Entry  Tue Apr 1 02:01:06 2025, Zac, Shahab, Ruijiu, Yuri, Sergey, Wolfram, Carlo, Michael, Accelerator, Settings lost 
Settings lost after the beam was lost. Trying to recover particle identification now that beam has returned.
Entry  Sat Apr 5 15:45:48 2025, Ruijiu, Ragan, Analysis, See single ion of 186Hf72+ and isomer in ntcap data Screenshot_2025-04-05_15-45-26.pngScreenshot_2025-04-05_15-55-38.pngScreenshot_2025-04-05_16-03-51.png
The ntcap data record 410 detector continuously. The frame length is  26 ms/frame * 32 frames= 832 ms.
Entry  Wed Apr 2 23:40:23 2025, JEL, ZN, General, Screenshots taken just as beam came back 2025-04-02_23-39-29-655.png2025-04-02_23-37-10-651.png2025-04-02_23-36-58-664.png
We are seeing spills being received but no peaks are seen in the analyzers. 

We are seeing several intermittent losses of beam. Awaiting action to see if it stabilizes.


23.51 Beam is back and we see the nice spectrum in the analyzer.
Entry  Fri Apr 11 15:49:41 2025, Shahab, General, Screenshots of RSAs 11x
Screenshots of RSAs showing acquisition settings, for documentation, they show the time / date on the bottom left, in case needed for data analysis.
Entry  Wed Apr 2 04:33:57 2025, Carlo, Zac, Chris, DAQ, Screenshots Lassie 2025-04-02_04-28-59-944_tcl1064.png2025-04-02_03-38-54-877_tcl1064.png
screenshots of Lassie
Entry  Thu Apr 3 03:48:40 2025, JEL, ZN, Runs, Screenshots 2025-04-03_03-47-28-530.png2025-04-03_03-47-11-337.png2025-04-03_03-47-42-665.png
The peaks in the analyzer are slowly shifting back to the original position. 
Note that a quadrupole was the cause of the issue 45 mins ago and it was cycled.  Might be relevant...
Entry  Thu Apr 3 06:16:32 2025, JEL, ZN, General, Screenshots 2025-04-03_06-15-12-250.png2025-04-03_06-15-00-458.png2025-04-03_06-14-54-153.png
Stable since last entry
Entry  Thu Apr 3 06:56:31 2025, JEL, ZN, Runs, Screenshots 2025-04-03_06-55-08-030.png2025-04-03_06-54-58-081.png2025-04-03_06-55-25-792.png
 
Entry  Thu Apr 3 07:59:09 2025, ZP, CN, ID, General, Screenshots 2025-04-03_07-58-00-874.png2025-04-03_07-57-08-478.png2025-04-03_07-57-36-781.png
Screenshots before opening ESR.
Entry  Thu Apr 3 10:07:34 2025, CN, ZP, CJG, MC, General, Screenshots 2025-04-03_10-04-14-352.png2025-04-03_10-04-23-381.png2025-04-03_10-05-06-655.png
 
Entry  Thu Apr 3 13:32:42 2025, CN, ID, General, Screenshots 2025-04-03_13-31-16-104.png2025-04-03_13-31-21-711.png2025-04-03_13-31-42-214.png
 
Entry  Thu Apr 3 16:44:18 2025, Usama, Kathrin, General, Screenshots 2025-04-03_16-44-51-040.png2025-04-03_16-45-58-954.png2025-04-03_16-46-46-981.png2025-04-03_16-48-47-815.png
 