60
|
Wed Apr 2 01:46:52 2025 |
Chris, Carlo, Zac | General | Beam loss | HKR just called to say a power supply to the
SIS18 extraction kicker has failed.
The service person has been called and is |
|
59
|
Wed Apr 2 00:59:43 2025 |
Zac, Carlo, Chris | Accelerator | Lost the beam | Beam was lost from 00:44 until 00:59 |
|
58
|
Wed Apr 2 00:08:57 2025 |
Ruijiu Chen,Shahab | Analysis | the peak corresponding to 194Pb⁸²⁺ was mixed with signals from some unknown ions. | I examined the spectrum of 194Pb at the 211
harmonic. It was observed that the peak corresponding
to 194Pb82+ was mixed with signals
|
 |
57
|
Tue Apr 1 23:56:18 2025 |
Shahab, Carlo, Zac, Yue, Michael | DAQ | Change of RSA01 settings for new harmonic=212. | 23:55 stop the RSAs.
410:
|
|
56
|
Tue Apr 1 23:23:18 2025 |
C Griffin | General | PLEIADES removed | Leakage currents were steadily increasing
in the PLEIADES detectors so we decided to
stop taking data, move both the detectors |
|
55
|
Tue Apr 1 23:07:15 2025 |
Shahab | DAQ | short interruption of queqiao script for RSAs | has been restored. |
|
54
|
Tue Apr 1 22:53:59 2025 |
Esther | General | Lassie exports | |
 |
53
|
Tue Apr 1 22:05:24 2025 |
Ruijiu | Analysis | analysis result | This is a preliminary result during 4:00-19:00
April 1st 2025.
I correct the frequency drift of 194Pb82+ |
   |
52
|
Tue Apr 1 22:03:07 2025 |
Jeroen, Zac, Esther, Shahab, Wolfram | DAQ | Optimisation of settings | Estimation of potential gain by changing.
Files from this points are going to rubbish.
Potential gains are c. 20%
|
|
51
|
Tue Apr 1 21:05:20 2025 |
Jeroen, Zac, Esther, Shahab, Wolfram | DAQ | Change of settings for shorter acq. window | > Acquisition stopped at 20:36.
>
> First file from this setting: RSA01-2025.04.01.03.52.59.247.tiq
|
|
50
|
Tue Apr 1 20:37:04 2025 |
Jeroen | DAQ | Change of settings for shorter acq. window | Acquisition stopped at 20:36.
First file from this setting: RSA01-2025.04.01.03.52.59.247.tiq
|
|
49
|
Tue Apr 1 20:19:23 2025 |
Jeroen, Zac, Esther | Accelerator | Beam fell out | > > No beam from 19:57:41.
>
> Beam back from 20:02 |
|
48
|
Tue Apr 1 20:02:19 2025 |
Jeroen, Zac, Esther | Accelerator | Beam fell out | > No beam from 19:57:41.
Beam back from 20:02 |
|
47
|
Tue Apr 1 20:00:14 2025 |
Jeroen, Zac, Esther | Accelerator | Beam fell out | No beam from 19:57:41. |
|
46
|
Tue Apr 1 17:08:13 2025 |
JG, ID, MC, CG | Detectors | pleiades in position | The pleiades detectors are now moved into
a position which does not disturb the stored
beam.
|
|
45
|
Tue Apr 1 16:47:32 2025 |
Ruijiu, Jan, Shahab | Analysis | The frequency of 194Pb82+ is changed to 408.600 MHz | |
 |
44
|
Tue Apr 1 16:44:32 2025 |
Jeroen, Esther | General | No SIS beam since 14:35 | Beam resumed at 16:40. |
 |
43
|
Tue Apr 1 15:38:50 2025 |
ruijiu chen | Analysis | frequency drift | |
 |
42
|
Tue Apr 1 15:32:59 2025 |
Zac | DAQ | NTCAP Restarted | NTCAP Has been restarted (we restart every
day around 15:00 so data goes in a new folder) |
|
41
|
Tue Apr 1 14:54:24 2025 |
all | General | No SIS beam since 14:35 | |
|