  170   Fri Apr 4 21:21:25 2025 BJ MC ID KKGeneralLassie screenshots   2025-04-04_21-19-41-612.png2025-04-04_21-19-38-467.png2025-04-04_21-19-11-284.png 
  169   Fri Apr 4 20:48:25 2025 IDGeneralPocket moved20:48: Inside pocket moved to 60mm and back
to the outside position.
  
  168   Fri Apr 4 20:29:22 2025 KK BJ MCGeneralLassie screenshots   2025-04-04_20-21-54-401.png2025-04-04_20-21-10-533.png2025-04-04_20-21-49-406.png 
  167   Fri Apr 4 19:19:06 2025 BJ KK MCGeneralLassie screenshots   2025-04-04_19-17-43-049.png2025-04-04_19-17-39-372.png2025-04-04_19-17-15-693.png 
  166   Fri Apr 4 18:38:52 2025 Dima, Zac, Sid, Kanika, Ragan, Shahab, BeatrizDAQnew file name and settings for 245 MHznew settings:
1.8 seconds recording on 245 MHz on RSA02
 IMG_4981.JPGIMG_4982.JPG 
  165   Fri Apr 4 18:24:31 2025 BJ KKGenerallassie screenshot   2025-04-04_18-23-01-532.png2025-04-04_18-22-56-326.png2025-04-04_18-22-34-200.png 
  164   Fri Apr 4 17:59:33 2025 Zac , SidDAQ17:58DAQ stopped with last file in RSA1-2025.04.04.17.58.49.340.tiq

Now the plan is to change one of the analyzers
  
  163   Fri Apr 4 17:30:25 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 188Hf72+ setting   sigmaVsFreq_For188Hfsetting.png 
  162   Fri Apr 4 17:13:12 2025 Team PleiadesDetectorsPLEIADES detector out17:12 We moved the PLEIADES detector out,
both are outside now (in parking position)
  
  161   Fri Apr 4 17:10:35 2025 H. Weick, S. LitvinovAcceleratorESR scraper settingthe new scraper setting for good isochronicity
but still acceptable intensity losses is:
Done at ~ 15:00 today.
  
  160   Fri Apr 4 17:04:39 2025 H. Weick, S. LitvinovAcceleratorslits after target, Bio_REM alarmA Bio-REM detector on the roof of ESR caused
an alarm and shut down the whole accelerator.
Too much primary beam going to ESR, noe we
 primary_beam_on_TE4_slits.JPG 
  159   Fri Apr 4 16:59:25 2025 KK BJDAQLassie screen shots   2025-04-04_16-57-35-759.png2025-04-04_16-57-28-066.png2025-04-04_16-56-54-385.png 
  158   Fri Apr 4 16:24:48 2025 Ruijiu, YuriAnalysisPID of 186HfCode used to add up injection data.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/2025.04.04.13.00$
find /data.local/G22-00018_00203/results/analyzers/RSA01
 7x 
  157   Fri Apr 4 16:12:54 2025 JG, IDGeneralpleiades detectors movingWe started moving the pleiades detectors at
16:13 04-04-2025.
  
  156   Fri Apr 4 16:12:14 2025 Team PLEIADESDetectorsInserting both PLEIADES detectorsWe are inserting both PLEIADES detectors step-wise,
one by one. Main beam should not be affected
too long.
  
  155   Fri Apr 4 16:01:09 2025 ID, MC, KanikaGeneral186Hf running now + Lassie screenshotsTuning is finished, 186Hf is running. Sharp
peaks now.
 2025-04-04_16-03-30-165.png2025-04-04_16-03-16-249.png2025-04-04_16-02-19-195.png 
  154   Fri Apr 4 14:47:29 2025 ID MG BJGeneralLassie screen shots186Hf screen shots with better resolution  2025-04-04_14-45-57-597.png2025-04-04_14-45-46-876.png2025-04-04_14-45-04-405.png 
  153   Fri Apr 4 14:01:20 2025 MG, ID,NHGeneralScreen shotLassie screen shots 186Hf  2025-04-04_13-57-43-428.png2025-04-04_13-57-48-930.png2025-04-04_13-56-37-564.png 
  152   Fri Apr 4 11:48:37 2025 MG, NH, IDGeneralsetting change to 186Hf + Lassie screenshots186Hf, 510MeV/u of 208Pb beam, ecooling not
working 
 2025-04-04_11-51-48-660.png2025-04-04_11-52-41-057.png2025-04-04_11-54-16-558.png 
  151   Fri Apr 4 11:44:31 2025 Ragan, Wolfram, Sergey, Zsolt, MagdaGeneral ESR setting change from 188Hf72+ to 186Hf72+ ESR setting is changed from 188Hf72+ to 186Hf72+.
SIS-18 beam energy for 
this fragment is 510 MeV/u.Brho = 7.86166
  