  43   Sat Mar 28 18:11:13 2020 Alex, YuriGeneralno beam in the ESR
Yuri and Sergey (on phone) have investigated extensively the problem with having no beam in the ESR. The FRS has been checked and seems OK. The ESR is fine as well.
The problem seems to be the timing. Ths SIS and the ESR seem to be completely out of synchronization. The on-call service for the control system has been called. 
  180   Tue Dec 8 15:47:07 2020 JanDetectorsmanual preamp & shaper settings for CsISiPhos
attached is a document showing fotos of all involved amplifiers in the chain to document the manual settings active during the experiment.

Summary:
Si-pad n-sides [MSI-8 (1)] were set to 5 GeV      (expected E-deposition ~2 GeV)
Si-pad p-sides [MPR-32 (1 & 2)] were set to 1 GeV (expected E-deposition ~2 GeV)
DSSD channels  [MSI-8 (2)] were set to 5 GeV      (expected E-deposition ~1.2 GeV)
CsI channels   [MSI-8 (2)] were set to 4 GeV      (expected E-deposition  46 GeV)

It seems we got clipped signals from the Si-pad p-sides, because the MPR-32 were saturated due to a wrong gain setting. 
This might explain, why there was not real influence on the spectra when adjusting MSCF settings for those channels.
 
I cannot comment on the CsI gain setting, because i don't know whether the given GeV-range by MesyTec directly applies for CsI & photodiode.

However, for DSSD and Si-pad n-sides the settings look okay.
  7   Tue Mar 12 12:54:58 2019 Chen, SidhuDAQhow to start DAQ and plot histogram.
1. login litv-exp account
rchen@lxg1254:/data.local2/2002_238UIMS$ ssh -X litv-exp@lxg0155.gsi.de
(don't login on lx-pool.)
litv-exp@lx-pool.gsi.de's password: ViValasVegas@****
2.login r4l-47 account
litv-exp@lxi087:~$ ssh r4l-47
litv-exp@r4l-47's password:ViValasVegas@****
3.start mbs
R4L-47 litv-exp > mbs
mbs>
mbs> -R4L-47 :msg_log :Message logger running
3.1 Initilizing, show, start and stop the acq



mbs> @startup
-R4L-47 Big grinispatch :Task "m_util" not started!
mbs> @startup
-R4L-47 :util :task m_util started
-R4L-47 :util :setup file setup.usf successfully loaded
-R4L-47 :util :trigger module set up as MASTER, crate nr: 0
-R4L-47 :util :enabled interrupt
-R4L-47 :collector Tongueipe type 2 or 4: virtual mapping
-R4L-47 :transport :task m_transport started
-R4L-47 :read_meb Tongueipe type 2 or 4: virtual mapping
-R4L-47 :transport :starting server in inclusive mode
-R4L-47 :transport :waiting for client (port 6000)
mbs> -R4L-47 :read_meb :task m_read_meb started
-R4L-47 :stream_serv:task m_stream_serv started
-R4L-47 :collector :task m_collector started

mbs> show acq
-R4L-47 Big grinispatch :Task "m_util" not started!


mbs> show acq
-R4L-47 :util :--------------------------------------------------------------
-R4L-47 :util :ACQUISITION INITIALIZED 12-Mar-19 13:44:09: active tasks:
-R4L-47 :util :m_util m_transport m_daq_rate m_collector m_stream_serv
-R4L-47 :util :m_read_meb
-R4L-47 :util :SB setup LOADED from setup.usf.
-R4L-47 :util :Readout table NOT LOADED, acquisition STOPPED.
-R4L-47 :util :There are 32 streams with 32 buffers a 32768 each.
-R4L-47 :util :Current crate is 0, event builder is RIO4.
-R4L-47 :util :--------------------------------------------------------------
-R4L-47 :util :Crate 0: ID= 20, LOCAL SYNC SYNC , subevent slots=200000.
-R4L-47 :util : trig 1: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 2: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 3: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 4: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 5: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 6: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 7: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 8: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 9: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 10: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 11: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 12: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 13: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 14: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util : trig 15: cvt= 300, fclrt= 12 [usec], max se length=100000 b
-R4L-47 :util :--------------------------------------------------------------
-R4L-47 :util :Name of output device =
-R4L-47 :util :Tape label = , Dismounted, file CLOSED
-R4L-47 :util : 0.000 [MB] written to tape, 0.000 to file
-R4L-47 :util :--------------------------------------------------------------
-R4L-47 :util :Collected: 0.0000 MB, 0 Buffers, 0 Events.
-R4L-47 :util :Rate : 0 KB/s, 0 Buffers/s, 0 Events/s
-R4L-47 :util :--------------------------------------------------------------


mbs> start acq
mbs> stop acq
-R4L-47 :util :stop acquisition
mbs> -R4L-47 :collector :acquisition NOT running
-R4L-47 :read_meb :found trig type 15 == stop acquisition

4. plot the histogram
litv-exp@lxi087:~/2019Munich-Det/Go4-Muenchen-3V785AH-1V830-simple$ go4
Go4 v5.3.2, build with ROOT 6.12/06 and Qt 4.8.6
Using Qt settings at /u/litv-exp/.config/GSI/go4.conf (default)




  175   Thu Oct 1 22:20:03 2020 JanDAQfinal unpacker config
We identified an issue with randomly missing adc channels in all lmd-files before run 0273.
This led to errors in the unpacking process. 

This issue is solved with the new config and mapping for the unpacker. 
The respective files are attached here. 
The unpacker is ready to use in /u/litv-exp/unpacker/unpackexps/E121

The adc issue is also understood. We deactivated the internal adc thresholds during the experiment, because we encountered the very same unpacker errors. This solved the problem for all later runs, but we forgot to think about a solution for the earlier runs. 
Mea culpa.

Jan 
  176   Mon Nov 2 16:45:55 2020 JanDAQf_user & mbslog
Attached is the f_user.c and the mbslog.l files.
The readout function is for the following setup:
3x ADC CAEN V785 
1x SCA CAEN V830
1x TDC CAEN V1190
1x Vulom TRB5 (triggerbox)
1x Vulom4b PEV (priority encoder)
1x TRIVA7
1x RIO4 R4L-47
  41   Sat Mar 28 16:12:25 2020 ruijiu, raganDAQenter ESR and turn on the HV crate.
  54   Sun Mar 29 14:29:13 2020 ruijiu e121_run_00240.lmd
s6 positon at 50mm.
  112   Wed Apr 1 01:05:36 2020 ruijiuDetectorsdetector position fixed at 60 mm
The detector cable was disconnected . We entered and reconnected the cable.
  58   Sun Mar 29 21:02:43 2020 ruijiuAnalysisdecay line of 205Tl beam
decay line of 205Tl beam with Ar gas jet target on and S6 slit at -8mm
Ar gas density~1e12 atoms/cm2
  182   Mon Mar 29 16:31:09 2021 Pierre-MichelDAQcross section
(1.393*^-8 + 3.18*^-13 + 4.707*^-8)/4.707*^-8 = 1.29595
  146   Sat Apr 4 13:41:04 2020 ShahabRunscooler down
cooler is down. only one device is off GECEBG2T. updated now it is working.
  168   Mon Apr 6 14:57:04 2020 ShahabRunscooler down
cooler component GECEBG2T again had to be reset.
  16   Tue Feb 25 15:49:58 2020 ruijiu chenDAQchanging scaling factor.
How to change scaling factor?
The parameters is in f_user.c file:
1. open the f_user.C with emacs :
R4L-47 litv-exp > emacs -nw f_user.c
2. change the parameters "MWPC_downscale". 
#define MWPC_downscale 0    // reduction = 2**MWPC_downscale                  
3.compile the program.
4. restart mbs.                                                                                                                                                               
  53   Sun Mar 29 14:01:45 2020 ruijiu beam position on DSSD
move the detector 1cm 
outside.from 60mm to 
70mm.
left direction is 
outside. right direction 
is 
inside(close to beam).
the spot is moving from 
left to right.
  39   Sat Mar 28 15:23:05 2020 Alex, Ragan, Mei Bai Generalbeam lifetime measurement
We see two species in the Schottky spectra during the beam lifetime measurement without the target. The one (probably the primiary beam) is significantly better cooled than the other.
So, we were wondering what is the other beam? Maybe the recombined ones?
  171   Thu Apr 9 11:47:28 2020 ruijiu backup data
2020.4.8  12:00Started copying 
data。
2020.4.9    11:52 Copied 6.3TB 
data. The copy speed is 65-67MB/s.
2020.4.15 Bring the two USB hard disk to my office and connect them  to lxg1298 computer.
Send email 
  172   Fri Apr 17 18:27:34 2020 ruijiuAnalysisbackup data
1.connect USB harddisk  to computer lxg1254 and  copy data to sever.

sync -rtmv --progress --checkSUD  /media/sdgl/data/ litv-exp@sbk0l9:/lustre/ap/litv-exp/2020-
04-14 e121_rchen/NTCAP/hd1

2020.05.02 08:06 copied 11.88 TB to server. 1.8TB rest on hard disk.
  110   Tue Mar 31 23:31:41 2020 ShahabRunsalpha_p calibration
Vc = 212849.9349
Ic = 0.2

1)

Vcc=6400
f= 245.314
Veff= 219218.2989884789
β= 0.7143483279777152 
γ= 1.4289995125817443  


2)

Vcc=6800
f=245.227
Veff= 219618.31558866
β= 0.7147234572628363 
γ= 1.4297823255462372  

3)

Vcc=6000
f=245.404
Veff= 218818.2823347592
β= 0.7139723840585469 
γ= 1.4282166995124788  


Taking 1) and 2):

η : 0.33044950273377705 

αp1: 0.15925696358166558 
αp2: 0.1587208769044816 

Taking 1) and 3):

η : 0.34166460537796267 

αp1: 0.14804186093747995 
αp2: 0.14857882942379202 

Taking 2) and 3):

η : 0.33653854822327256 

αp1: 0.1526318314149861 
αp2: 0.15370488657848214  


αp average: 0.1534892081401479
  157   Sun Apr 5 13:05:43 2020 Ragan, ShahabRunsZero measurement (S2: 0/35 mm and S6: -20/7 mm)
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 0 hr
S2: 0/35 mm
s6: -20/7

purpose: data with TARGET ON

Detector position (CsISiPHOS):  out of the ring
Detector position (MWPC):  -60 mm

run start at 19:02,  run0343.lmd 
file running: 0511.lmd

_______________________________________________________________________________

time when accumulation starts: 12:59
storage time at Manipulation 9 starts at: 13:
storage time at Manipulation 9 stops at:  14:  
I cooler during storage at Manipulation 9: -1 mA (20 mA)
time spend at manipulation 13 : 5 mins
(i.e. time for which electron cooler is on after gas jet) 

I_cooler = -1 mA  (20 mA)


I_SIS: 1.8e9      
ESR particles after stacking: e6 (offset 5e5)
Number of stackings: 100  
Target ON density at SC 7 E 07: 4.11e12 
Target on time for measurement: 10 mins (by event mode) 
Target ON density at SC 12 E 12: 4.11e12
Target on time for measurement: 5 sec (by event mode)



NTCAp file:
SC_2020-04-04_19-04-52
\IQ_2020-04-04_19-04-52
IQ rate: 8 MS/s
(saved in drive : O)

copy and repeat the above (below the line) for every storage time measurement
  122   Thu Apr 2 21:03:40 2020 Ragan, Yuri, Sergey, NikosRunsZero hour measurement (S2:-10/35 mm)
beam: 205Tl81+ (no scraping, Al ~1g/cm2)
energy: 400 MeV/u
storage time: zero hrs
S2:-10/35 mm

purpose: data with TARGET ON

Detector position (CsISiPHOS):  out of the ring
Detector position (MWPC):  -60 mm

run start at 19:05 , first file: run0292.lmd (File was started when stacking was ongoing. Maybe not all the stackings could be sen in the analysis.)
file running: 0292.lmd

_______________________________________________________________________________

time when accumulation starts: --
time when storage starts: 19:10
time when storage ends: 19:10
I_cooler during storage time: --

I_cooler =  177 mA


I_SIS: 2.2e9      
ESR particles after stacking: 3.5e6   (offset 1e5)
Number of stackings: ~40 (can be checked on NTCap data)
Target ON density: 3.45e12 
Target on time for measurement: 10 mins (by event mode)       


NTCAp file:
SC_2020-04-02_19-10-21
\IQ_2020-04-02_19-10-14
IQ rate: 8 MS/s
(saved in drive : p)

copy and repeat the above (below the line) for every storage time measurement