  113   Thu Apr 2 02:36:48 2020 RaganGeneralStochastic cooling and orbit problem
On 1 April by 5 pm, we could stop the stochastic cooling after the stacking process and also change the orbit of the Tl beam to centre. 
Thanks to the efforts by the ESR team !
  18   Thu Mar 26 17:21:40 2020 RaganGeneralStochastic cooling
1) From SIS, 206Pb67+ @401.17 MeV/u goes to FRS where only SEETRAM is placed in the target area to strip off 206Pb67+ to get 206Pb81+.
2) There is 206Pb81+ (H-like primary beam) inside ESR at 400 MeV/u.
3) The ESR team is now trying Stochastic cooling with 206Pb81+ beam at 400 MeV/u.
  19   Fri Mar 27 13:02:07 2020 RaganGeneralStochastic cooling
1) ESR team is successful with the Stochstic cooling of primary H-like 206Pb81+ beam @400 MeV/u.
2) Now, they are trying for stacking of the beam.
Attachment 1: stochastic_cooling.PNG
stochastic_cooling.PNG
  133   Fri Apr 3 11:52:27 2020 ShahabRunsStacking 54 times!
Attachment 1: 2020-04-03_11-48-11-781.png
2020-04-03_11-48-11-781.png
  138   Fri Apr 3 14:08:41 2020 ShahabRunsStacking
Attachment 1: 2020-04-03_14-07-13-250.png
2020-04-03_14-07-13-250.png
  144   Sat Apr 4 03:27:48 2020 Ragan, Pierre-Michel, Dima, ShahabRunsSix hour measurement (S2: 0/35 mm and S6: -20/7 mm)
beam: 205Tl81+ (no scraping , Al ~1g/cm2)
energy: 400 MeV/u
storage time: 6 hr
S2: 0/35 mm
s6: -20/7

purpose: data with TARGET ON

Detector position (CsISiPHOS):  out of the ring
Detector position (MWPC):  -60 mm

run start at 22:11,  run0308.lmd 
file running: 0312.lmd

_______________________________________________________________________________

time when accumulation starts: 02:52
time when storage starts: 03:22
time when storage ends: 09:22
I_cooler during storage time: -1 mA

I_cooler =  177 mA


I_SIS: 1.75e9      
ESR particles after stacking: 1.91e6 (offset 5e5)
Number of stackings: 80  
Target ON density: 4.23e12 
Target on time for measurement: 10 mins (by event mode)      
time spend at manipulation 13 : 8 mins
(i.e. time for which electron cooler is on after gas jet) 


I_ESR (04:00) :  1,76e6
I_ESR (04:30) :  1,62e6
I_ESR (05:00) :  1,56e6
I_ESR (05:30) :  1,42e6
I_ESR (06:00) :  1,33e6
I_ESR (06:30) :  1,27e6
I_ESR (07:00) :  1,20e6
I_ESR (07:30) :  1.12e6
I_ESR (08:00) :  -
I_ESR (08:30) :  -
I_ESR (09:00) :  9.8e5



NTCAp file:
SC_2020-04-03_22-12-50
\IQ_2020-04-03_22-13-48
IQ rate: 8 MS/s
(saved in drive : O)

copy and repeat the above (below the line) for every storage time measurement
Attachment 1: 06F75D44-5DC0-4EF5-A574-C79E559EA8E0.jpeg
06F75D44-5DC0-4EF5-A574-C79E559EA8E0.jpeg
Attachment 2: E0E0700F-4164-44C8-86D8-8F782D4A81E6.jpeg
E0E0700F-4164-44C8-86D8-8F782D4A81E6.jpeg
Attachment 3: 689A47E2-D32B-4721-A6F8-F4FC53BB513E.jpeg
689A47E2-D32B-4721-A6F8-F4FC53BB513E.jpeg
  181   Tue Dec 15 09:25:41 2020 JanDAQSiCsIPhos signal/amplitude reconstruction
Attachment 1: amps.pdf
amps.pdf amps.pdf
  14   Fri Feb 21 11:30:52 2020 LaszloGeneralShift plan
e127: https://docs.google.com/spreadsheets/d/14m8WcCq1erx6HqWJRK7TLbCx121IkjqGa5l-frf4YjI/edit#gid=0

e121: https://docs.google.com/spreadsheets/d/10MUzA5-Ilf2WzCyNj8u_KSG6yzPg0e4vtZGGPFB3K-k/edit#gid=0
  34   Sat Mar 28 13:09:11 2020 Mei,Yury, Tino, Ragan, RuijiuGeneralShift plan
From Yury,

For now, measure the beam life time with 3 different electron current in the e-cooler,i.e. 200mA(default), 10mA, and 20mA. For each current, 4 sets of 30mins long measurements shall be taken.

Starting from 9pm Helmut and Sergey will come for setting up FRS
  109   Tue Mar 31 21:07:05 2020 RaganGeneralSeparation of 203Tl80+ and 200Hg79+ using scrapper in ESR
It can be seen in the video how 203Tl80+ (on extreme left) and then 200Hg79+ (in middle originally) is separted from 205Tl81+ by using scrapper in ESR.
Now, we want 205Pb81+ mixed with 205Tl81+ to be separated as much as possible in FRS.
Attachment 1: 06B012F5-5435-41D7-AD82-4A5FDADF281E.MOV
  69   Mon Mar 30 02:27:44 2020 RaganRunsSecond measurement with 206Pb81+ beam at I_cooler = 200 mA
I_cooler = 200 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 02:24 , run file: run0267.lmd  (0266.lmd is garbage file)
run stop at :

_______________________________________________________________________________

time: 02:24

I_cooler = 176 mA

SIS particles before:  2.5E8        
ESR particles:  4.9E6
        


NTCAp file:
SC_2020-03-30_02-27-10
IQ_2020-03-30_02-27-10
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  71   Mon Mar 30 02:58:51 2020 Sergiy, DimaRunsSecond measurement with 206Pb81+ beam at I_cooler = 200 mA
I_cooler = 200 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 02:24 , run file: run0267.lmd  (0266.lmd is garbage file)
file running: 0267.lmd

_______________________________________________________________________________

time: 03:00

I_cooler = 176 mA
      
ESR particles:  4.2E6
        


NTCAp file:
SC_2020-03-30_02-27-10
IQ_2020-03-30_02-27-10
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  72   Mon Mar 30 03:30:03 2020 Sergiy, DimaRunsSecond measurement with 206Pb81+ beam at I_cooler = 200 mA
I_cooler = 200 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 02:24 , run file: run0267.lmd  (0266.lmd is garbage file)
file running: 0267.lmd

_______________________________________________________________________________

time: 03:30

I_cooler = 176 mA
      
ESR particles:  3.6E6
        


NTCAp file:
SC_2020-03-30_02-27-10
IQ_2020-03-30_02-27-10
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  73   Mon Mar 30 04:00:19 2020 Sergiy, DimaRunsSecond measurement with 206Pb81+ beam at I_cooler = 200 mA
I_cooler = 200 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 02:24 , run file: run0267.lmd  (0266.lmd is garbage file)
file running: 0267.lmd

_______________________________________________________________________________

time: 04:00

I_cooler = 176 mA
      
ESR particles:  3.0E6
        


NTCAp file:
SC_2020-03-30_02-27-10
IQ_2020-03-30_02-27-10
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  75   Mon Mar 30 04:30:17 2020 Sergiy, DimaRunsSecond measurement with 206Pb81+ beam at I_cooler = 200 mA
I_cooler = 200 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 02:24 , run file: run0267.lmd  (0266.lmd is garbage file)
file running: 0267.lmd

_______________________________________________________________________________

time: 04:30

I_cooler = 176 mA
      
ESR particles:  2.5E6
        


NTCAp file:
SC_2020-03-30_02-27-10
IQ_2020-03-30_02-27-10
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  74   Mon Mar 30 04:15:29 2020 RaganGeneralSecond measurement with 206Pb81+ beam at I_cooler = 200 mA
In the picture below, a very nice storage of 206Pb81+ at 200 mA electron cooler current for no gas jet target can be seen in ESR. The measurement started at 02:24 and we will now finish it in 5-10 mins. We will now do two more measurements for I_cooler = 10 mA ans 20 mA.
Attachment 1: 1A7AE154-6A88-4AED-BA5D-748025FCD226.jpeg
1A7AE154-6A88-4AED-BA5D-748025FCD226.jpeg
  76   Mon Mar 30 06:15:13 2020 RaganRunsSecond measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 06:08 , run file: run0270.lmd  (0268.lmd and 0269.lmd are garbage files)
run stop at :

_______________________________________________________________________________

time: 06:08

I_cooler = -1 mA

SIS particles before:  2.5E8        
ESR particles:  3.01E6
        


NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  78   Mon Mar 30 06:30:52 2020 RaganRunsSecond measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 06:08 , run file: run0270.lmd  (0268.lmd and 0269.lmd are garbage files)
file running: 0270.lmd

_______________________________________________________________________________

time: 06:30

I_cooler = -1 mA

      
ESR particles:  2.6E5
        


NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  80   Mon Mar 30 07:02:15 2020 tinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 06:08 , run file: run0270.lmd  (0268.lmd and 0269.lmd are garbage files)
file running: 0270.lmd

_______________________________________________________________________________

time: 07:00

I_cooler = -01 mA

      
ESR particles:  2.2E5
        


NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes
  81   Mon Mar 30 07:34:06 2020 TinoRunsSecond measurement with 206Pb81+ beam at I_cooler = 20 mA
I_cooler = 20 mA

beam: 206Pb81+
energy: 400 MeV/u

purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas

Detector position (CsISiPHOS): 60 mm
Detector position (MWPC):     -10 mm

run start at 06:08 , run file: run0270.lmd  (0268.lmd and 0269.lmd are garbage files)
file running: 0270.lmd

_______________________________________________________________________________

time: 07:30

I_cooler = -01 mA

      
ESR particles:  2.8E5
        


NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)

copy and repeat the above (below the line) every 30 minutes