HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  proton-capture on 118Te  Not logged in ELOG logo
Message ID: 25     Entry time: Wed Oct 23 14:51:43 2019
Author: Jan, Laszlo 
Category: DAQ 
Subject: VME modules & main.cfg 
Year:  
Here is the current list of VME modules in our DRASI daq including HW addresses:

Slot <module> [HW addr.]

1 <RIO4>
2 <Vulom4b> [0500]
3 <ENV3>
5 <scaler V830> [00E1]
7 <scaler V830> [00E2]
15 <TDC V775> [00C1]
17 <TDC V775> [00C2]
19 <MADC> [00A1]
21 <MADC> [00A2]

See also main.cfg attached
Attachment 1: main.cfg  728 Bytes  Uploaded Wed Oct 23 16:25:34 2019  | Hide | Hide all
CRATE("Master")
{
	GSI_VULOM(0x05000000) {
		trlo2_master = true
	}
	MESYTEC_MADC32(0x00A10000) {
		  nim_busy = gate0
   	          range = 10 V
		  resolution=8
		  hires=true
	}
	BARRIER
	MESYTEC_MADC32(0x00A20000) {
	          nim_busy = gate0
		  range = 10 V
		  resolution=8
		  hires=true
	}
	BARRIER
	CAEN_V775 (0x00C10000) {
		  common_start = false
		  time_range = 1200 ns
		  suppress_invalid = true
		  suppress_over_range = true
	}
	BARRIER
	CAEN_V775 (0x00C20000) {
		  common_start = false
		  time_range = 1200 ns
		  suppress_invalid = true
		  suppress_over_range = true
	}
	BARRIER
        CAEN_V830 (0x00E10000) {
		  resolution = 32	
        }
	BARRIER
	CAEN_V830 (0x00E20000) {
		  resolution = 32
	}
}
ELOG V3.1.5-fc6679b