HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  proton-capture on 118Te, Page 17 of 29  Not logged in ELOG logo
ID Date Author Categorydown Subject Year Text Attachments
  106   Sat Mar 21 06:02:22 2020 Tino, OliverGeneralDetector filling Run stopped for detector fillings   
  115   Sat Mar 21 10:20:27 2020 Ragan, AlexGeneralTarget LN2 The LN2 Dewar on the ESR roof has been refilled.   
  119   Sat Mar 21 11:30:04 2020 LaszloGeneralMWPC movement now we try to move the capture detector (MWPC
in the 1. dipol before our Si setup) inside
the ring while the DAQ was ON
 MWPC_movement.png 
  122   Sat Mar 21 12:02:57 2020 Ragan, LaszloGeneralrun entry - run061 12:02 pm - scapper is taken out completely

open file : runstart061
  
  123   Sat Mar 21 12:06:50 2020 LaszloGeneralrun61 - SCRAPER moved out we want to see any change on the Silicon count
rate, because we will have now also Rutherford
scattering. 
  
  125   Sat Mar 21 12:32:00 2020 LaszloGeneralEstimated target thickness Target thickness must be like 5mm (was measured
with a moving thin wire)
The beam thickness is small because of the
  
  126   Sat Mar 21 12:42:21 2020 RaganGeneralEntry to ESR for MCP detector Pierre Michel and Laszlo go inside the ESR
for switching on the MCP detector so that
the photons from the gas jet and secondary
  
  130   Sat Mar 21 14:52:05 2020 LaszloGeneraltarget optimization previous position of the beam at target was
-3mm (for the night position)
max. intensity position of the beam at target
 IMG_20200321_145105.jpgIMG_20200321_145059.jpg 
  133   Sat Mar 21 15:26:49 2020 LaszloGeneralSCRAPER is ON use again Yuri puts back the scraper (Egelhof 1 - GE01DD1IG)
into position = +19. (where it was in the
evening)
  
  134   Sat Mar 21 15:30:34 2020 SergiyGeneralgo into the ESR We are going into the ESR to check the electronics.
Use calibration sources (133Ba etc).
  
  135   Sat Mar 21 17:21:57 2020 LaszloGeneralnew Target density Ulli and Nikos managed to set the target density
to ~7E13  at 51K temperature
  
  138   Sat Mar 21 17:34:10 2020 SergiyGeneralRecoils 
We started recording the data from the recoils
using the MCP from Pierre-Michael's experiment.
  
  140   Sat Mar 21 18:13:22 2020 ShahabGeneralrough comparison gas target off and on rough comparison of life time at 10 MeV/u
when target off with on. more noise in background
means weaker signal.
 target_effect.jpg 
  151   Sat Mar 21 23:07:00 2020 LaszloGeneral1672. MCP file was (recoils) was not closed 1672. MCP file was  (recoils) was not closed
when we refilled the Xrays and did the cable
change of 90 and 145 xrays
  
  177   Sun Mar 22 10:05:37 2020 Esther, RaganGeneralrun entry - run079 The intensity of beam from SIS is less due
to some issues with UNILAc.
  
  179   Sun Mar 22 10:28:27 2020 Esther, RaganGeneralrun entry - run079 The problem at UNILAC seems to have solved
itself. Intensity is returning to normal.
  
  183   Sun Mar 22 12:01:44 2020 Esther, RaganGeneralVacuum problem with SIS There is some problem with the vacuum in SIS
and thus data recording is stopped.
  
  186   Sun Mar 22 12:53:43 2020 LaszloGeneralquick summary for the 118Te overnight measurement Quoting Yury:
"The count rate is very low. We estimate
that we store about 10^4 118Te particles
 118Te_after13h_measurement.png118Te_Xray_Espectra.png 
  188   Sun Mar 22 13:33:19 2020 LaszloGeneral2nd storage of MCP data I made a backup for the MCP data on my own
GSI laptop. Looking for better solution...
the original "fresh" files stored at litv-exp@lxg1299:/data.local2/hillenbrand/Laszlo/
  
  191   Sun Mar 22 14:58:59 2020 LaszloGeneraldropping density of Gasjet after like 20min run, the density of the gasjet
already dropped from 10^14 to 8.7*10^13.
Now it seems to remain in that value
 ga_jet_drop.png 
ELOG V3.1.5-fc6679b