Sat Mar 21 23:07:00 2020, Laszlo, General, 1672. MCP file was (recoils) was not closed,
|
1672. MCP file was (recoils) was not closed when we refilled the Xrays and did the cable change of 90 and 145 xrays
These stored in lxg1299 local disk |
Fri Mar 20 01:36:48 2020, Laszlo, General, 124Xe primary beam at 10Mev TargetON,
|
We didmt see any effect on the lifetime if the target is switched on. It is because we use only hydrogen target (but why
is.it so?) |
Thu Mar 19 23:48:56 2020, Laszlo, General, 124Xe primary beam at 10Mev TargetOFF,
|
Beam lifetime is estimated to be 11sec at least (hard to.see with the cursor the corrct values on the shottky monitor)
but Yury says it is even
~20sec. The particle njmbers are on the attached picture, however at 10Mev the cirrent measurement is not.really
|
Tue Jul 23 10:46:29 2019, Laszlo, Analysis, 124Xe pg peak fit using mixed cascade simulation, 7x
|
This entry is the continuation of the cascade effects on the pg peak shape entry:
https://exp-astro.physik.uni-frankfurt.de:8080/E108/475
|
Fri Mar 20 13:21:33 2020, Jan, Laszlo, Analysis, 124Xe data of first night,
|
The unpacked data of all runs from the first night (46-50) is located at
litv-exp@lxg0188:/data.local2/E127_lmd/124Xe_1st_night.root
|
Sat Mar 21 23:19:14 2020, Jan, Analysis, 118Te52+ on H2-target - Xray spectrum 90 degree,
|
The attached spectrum is for the 90 degree X-ray detector taken for about 3 hours with 118Te52+.
We see two peaks at ~29 keV (K-alpha) and 44 keV (K-REC).
|
Fri May 28 15:15:06 2021, Jan, Analysis, 118Te(p,g) counts runs 135 to 174, 2021
|
This is the summary of all Si data collected at 6 MeV/u until run174 before the Alvarez problem.
We have roughly 50-60 counts in the peak region.
This data corresponds roughly to 36hours of beam, which means ~1.5 to 2 counts/hour. |
Mon Feb 17 08:14:44 2020, Jan, Simulations, 118Te K-REC X-ray energies,
|
X-ray energies of K-REC for 118Te according to
[URL=http://www-ap.gsi.de/Thomas/ap_html_research/energy/index.php]http://www-ap.gsi.de/Thomas/ap_html_research/energy/index.php[/URL]
|
Tue May 25 11:58:30 2021, Jan, Analysis, 118(p,g) counts until run0115, 2021
|
The two attached plots show the collected Si data up to run0115.
Within this ~15h we have about ~70 counts in the peak region.
|
Tue May 25 09:53:04 2021, Oliver, Diego, Runs, (No)Run 0114, 2021
|
Run0114 was started after ESR optimization but immedieatly again stopped...
at 09:52:34 on 25.05.2021 |
Sat Mar 21 01:44:57 2020, Laszlo, General, ,
|
from the SIS side they could optimize the intensity. we gained a factor ~3. Now the SIS intensity is at |
Tue Apr 21 22:25:00 2020, Jan, Analysis, ,
|
|