  559  
 | 
Sun May 30 04:27:58 2021 | 
Oliver, Diego | Runs | Run 0208 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0208.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  04:27:30 30.05.2021 
run stop:   05:32:04 30.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 100 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  420 nA 
 
 
SIS particles before:      2.5e9 (one shoot) 
ESR current at injection:  2.5e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  558  
 | 
Sun May 30 03:30:37 2021 | 
Oliver, Diego | Runs | Run 0207 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0207.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  03:30:06 30.05.2021 
run stop:   04:27:27 30.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 120 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  420 nA 
 
 
SIS particles before:      2.6e9 (one shoot) 
ESR current at injection:  2.9e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  557  
 | 
Sun May 30 02:26:07 2021 | 
Oliver, Diego | Runs | Run 0206 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0206.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  02:25:37 30.05.2021 
run stop:   03:30:03 30.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 130 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  420 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  2.75e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  556  
 | 
Sun May 30 01:22:03 2021 | 
Oliver, Diego | Runs | Run 0205 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0205.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  01:21:34 30.05.2021 
run stop:   02:25:32 30.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 100 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  410 nA 
 
 
SIS particles before:      2.5e9 (one shoot) 
ESR current at injection:  2.75e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  555  
 | 
Sun May 30 00:19:33 2021 | 
Oliver, Diego | Runs | Run 0204 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0204.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  00:18:57 30.05.2021 
run stop:   01:21:30 30.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 100 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  400 nA 
 
 
SIS particles before:      2.5e9 (one shoot) 
ESR current at injection:  2.5e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  554  
 | 
Sun May 30 00:14:58 2021 | 
Oliver, Diego | General | SIS Pattern changed | 2021 | 
The pattern in SIS was changed so that we get more injections into ESR. Before HTD had 9 seconds which resulted in a timeout in the ESR. Now HTD has 10 seconds which improved a lot...  | 
| 
  553  
 | 
Sat May 29 23:18:43 2021 | 
Oliver, Diego | Runs | Run 0203 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0203.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  23:18:19 29.05.2021 
run stop:   00:18:53 30.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  410 nA 
 
 
SIS particles before:      2.0-2.9e9 (one shoot) 
ESR current at injection:  1.8e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  552  
 | 
Sat May 29 23:05:52 2021 | 
Oliver, Diego | General | No Beam | 2021 | 
Due to a radioprotection issue in CaveA there is no beam. We wait for the radioprotection shift to arrive...
Beam back at 23:18  | 
| 
  551  
 | 
Sat May 29 22:03:28 2021 | 
Sophia, Mario | Runs | Run 0202 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0202.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  22:02:07 29.05.2021 
run stop:   22:24:21 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  550  
 | 
Sat May 29 21:37:54 2021 | 
Sophia, Mario | Runs | Run 0201 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0201.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  21:01:17 29.05.2021 
run stop:   22:02:02 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  549  
 | 
Sat May 29 20:35:22 2021 | 
Sophia, Mario | Runs | Run 0200 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0200.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  20:33:36 29.05.2021 
run stop:   20:45:12 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  548  
 | 
Sat May 29 19:34:41 2021 | 
Sophia, Mario | Runs | Run 0199 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0199.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  19:33:33 29.05.2021 
run stop:   20:33:33 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  547  
 | 
Sat May 29 18:29:26 2021 | 
Sophia, Mario | Runs | Run 0198 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0198.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  18:28:12 29.05.2021 
run stop:   19:33:30 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  546  
 | 
Sat May 29 17:28:26 2021 | 
Sophia, Mario | Runs | Run 0197 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0197.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  17:27:32 29.05.2021 
run stop:   18:28:10 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          10E14  | 
| 
  545  
 | 
Sat May 29 16:28:50 2021 | 
Sophia, Mario | Runs | Run 0196 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0196.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  16:27:45 29.05.2021 
run stop:   17:27:27 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0e13 at 17:00 it increased during LN2 filling to 10E14  | 
| 
  544  
 | 
Sat May 29 15:26:40 2021 | 
Sophia, Mario | Runs | Run 0195 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0195.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  15:25:44 29.05.2021 
run stop:   16:27:45 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0e13 | 
| 
  543  
 | 
Sat May 29 13:43:39 2021 | 
Tino, Rene, Yuri, Laszlo, Markus | Runs | change of settings | 2021 | 
from now on, everal beam setting will be different. We could not get the beam back to were it was before. When the scraper was pulled back by 2 cm, the loe/energy beam was visible again via cap. 
Schottky. However, no x-rays could be observerved during the target-on phase. 
Hence the interpretation:
beam position has change at least a few mm, at most 2 cm. 
Will now try to get a new overlap with target and need to adjust the detector position too.
All online - Si spectra are cleared.  | 
| 
  542  
 | 
Sat May 29 11:01:04 2021 | 
Rene, Tino | Runs | Run 0194 crap run | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0194.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +2.0 mm  
 
run start:  12:22:55 29.05.2021 
run stop:   12:49:05 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          1.0e14 | 
| 
  541  
 | 
Sat May 29 10:09:01 2021 | 
Rene, Tino | Runs | Run 0193 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0193.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +2.0 mm  
 
run start:  10:07:35 29.05.2021 
run stop:   10:59:10 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 3   Hz  
Xray_ON_bdt:  ~ 110 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: 2.5e6 
Target ON density:          1.0e14 | 
| 
  540  
 | 
Sat May 29 08:59:52 2021 | 
Rene, Tino | Runs | Run 0192 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0192.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +2.0 mm  
 
run start:  09:07:18 29.05.2021 
run stop:   10:07:34 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 2.5   Hz  
Xray_ON_bdt:  ~ 110 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: 2.5e6 
Target ON density:          1.0e14 |