| ID | 
Date | 
Author  | 
Category | 
Subject | 
Year | 
| 
  105  
 | 
Sat Mar 21 06:00:19 2020 | 
Tino, Oliver | Runs | run entry - run054 |   | 
Open file: runstart054
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 05:00 , first file: run054_0001.lmd
run stop  at xx:xx , last file:  run0xx_0xxx.lmd
_______________________________________________________________________________
time: 06:00 am.
ON Rates
Si_X:      0 Hz
Si_Y:      0 Hz
Xray_35:   0 Hz
Xray_90:   58 Hz
Xray_145:  0 Hz
BaF_OR:    - Hz
Si voltage:          60.02 V  
Si leakage current:  4.01 uA
SIS particles before:           2.2e9
ESR particles at injection:     estimated ~10^5 - 10^4
ESR particles after decel.:     
Target ON density:              1.47e13
copy and repeat the above (below the line) every 30 minutes  | 
| 
  106  
 | 
Sat Mar 21 06:02:22 2020 | 
Tino, Oliver | General | Detector filling |   | 
Run stopped for detector fillings  | 
| 
  107  
 | 
Sat Mar 21 06:29:36 2020 | 
Tino, Oliver | Runs | run entry - run055 |   | 
Open file: runstart055
beam: 118Te52+
energy: 10 MeV/u
purpose: data with TARGET ON
Detector position (Si): -24 mm
run start at 06:29 , first file: run055_0001.lmd
run stop  at xx:xx , last file:  run0xx_0xxx.lmd
_______________________________________________________________________________
time: 06:29 am.
ON Rates
Si_X:      0 Hz
Si_Y:      0 Hz
Xray_35:   0 Hz
Xray_90:   36 Hz
Xray_145:  25 Hz
BaF_OR:    - Hz
Si voltage:          60.02 V  
Si leakage current:  4.04 uA
SIS particles before:           2.3e9
ESR particles at injection:     estimated ~10^5 - 10^4
ESR particles after decel.:     
Target ON density:              1.36e13
copy and repeat the above (below the line) every 30 minutes  | 
| 
  362  
 | 
Fri May 21 11:27:31 2021 | 
Sophia, Mario, Laszlo | Runs | Run 0052 | 2021 | 
open file : e127b_run0052.lmd 
 
beam: 124Xe54+ 
energy: 7 MeV/u 
cooler voltage: 
 
purpose:  
Illumination of the detector to see if the gain settings are ok. 
Spectra look reasonable, rates are low. 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): out/not used 
 
run start: 11:23:58 21-05-2021 
run stop:  12:13:53 21-05-2021 
 
_______________________________________________________________________________ 
 
ON Rates 
Si_bdt:     15 Hz 
Xray_35:    20 Hz 
Xray_90:    200 Hz 
Xray_145:   70 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  360 uA 
 
 
SIS particles before:            
ESR current at injection:       3e7 
ESR particles after decel.:     5e6 
Target ON density:              9e13 | 
| 
  415  
 | 
Mon May 24 11:12:38 2021 | 
Sophia, Mario | Runs | Run 0090 | 2021 | 
DAQ node 2 was not started! 
 
 
open file : e127b_run0090.lmd 
 
beam: 124Xe54+ 
energy: 7 MeV/u 
cooler voltage: 
 
purpose:  
Reference  measurement with scraper 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam) 
 
run start: 11:10:18 23.05.2021 
run stop:   
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    0 Hz 
Xray_ON_bdt: 0  Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  340 uA 
 
 
SIS particles before:      7.6e8 
ESR current at injection:  1e6 (stacked)     
ESR particles after decel.: 4e6  
Target ON density:          1.0e14 | 
| 
  416  
 | 
Mon May 24 11:25:46 2021 | 
Sophia, Mario | Runs | Run 0091 | 2021 | 
open file : e127b_run0091.lmd 
 
beam: 118Te52+ 
energy: 7 MeV/u 
cooler voltage: 
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam) 
 
run start: 11:25:08 25.05.2021 
run stop:  12:26:31 24.05.2021 
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    0 Hz 
Xray_ON_bdt: 0  Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  340 uA 
 
 
SIS particles before:      7.6e8 
ESR current at injection:  1e6 (stacked)     
ESR particles after decel.: 4e6  
Target ON density:          1.0e14 | 
| 
  417  
 | 
Mon May 24 12:29:20 2021 | 
Sophia, Mario | Runs | Run 0092 | 2021 | 
20 stacks now 
 
open file : e127b_run0092.lmd 
 
beam: 118Te52+ 
energy: 7 MeV/u 
cooler voltage: 
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam) 
 
run start: 12:28:57 24.05.2021 
run stop:  13:13:56 24.05.2021 
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    0 Hz 
Xray_ON_bdt: 0  Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  340 uA 
 
 
SIS particles before:      7.6e8 
ESR current at injection:  1e6 (stacked)     
ESR particles after decel.: 4e6  
Target ON density:          1.0e14 | 
| 
  418  
 | 
Mon May 24 13:14:59 2021 | 
Sophia, Mario | Runs | Run 0093 | 2021 | 
No. of stacks: 5 
length SC10: 2x 5.5s  
 
open file : e127b_run0093.lmd 
 
beam: 118Te52+ 
energy: 7 MeV/u 
cooler voltage: 
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam) 
 
run start: 13:14:44 24.05.2021 
run stop:  14:10:55 24.05.2021 
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    0 Hz 
Xray_ON_bdt: 0  Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  340 uA 
 
 
SIS particles before:      7.6e8 
ESR current at injection:  1e6 (stacked)     
ESR particles after decel.: 4e6  
Target ON density:          1.0e14 | 
| 
  419  
 | 
Mon May 24 14:12:14 2021 | 
Sophia, Mario | Runs | Run 0094 | 2021 | 
No. of stacks: 5 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -10 mm (before -20 mm) 
 
open file : e127b_run0094.lmd 
 
beam: 118Te52+ 
energy: 7 MeV/u 
cooler voltage: 
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam) 
 
run start: 14:15:47 24.05.2021 
run stop:  15:20:37 24.05.2021 
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    0 Hz 
Xray_ON_bdt: 0  Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  340 uA 
 
 
SIS particles before:      7.6e8 
ESR current at injection:  1e6 (stacked)     
ESR particles after decel.: 4e6  
Target ON density:          1.0e14 | 
| 
  544  
 | 
Sat May 29 15:26:40 2021 | 
Sophia, Mario | Runs | Run 0195 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0195.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  15:25:44 29.05.2021 
run stop:   16:27:45 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0e13 | 
| 
  545  
 | 
Sat May 29 16:28:50 2021 | 
Sophia, Mario | Runs | Run 0196 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0196.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  16:27:45 29.05.2021 
run stop:   17:27:27 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0e13 at 17:00 it increased during LN2 filling to 10E14  | 
| 
  546  
 | 
Sat May 29 17:28:26 2021 | 
Sophia, Mario | Runs | Run 0197 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0197.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  17:27:32 29.05.2021 
run stop:   18:28:10 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          10E14  | 
| 
  547  
 | 
Sat May 29 18:29:26 2021 | 
Sophia, Mario | Runs | Run 0198 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0198.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  18:28:12 29.05.2021 
run stop:   19:33:30 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  548  
 | 
Sat May 29 19:34:41 2021 | 
Sophia, Mario | Runs | Run 0199 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0199.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  19:33:33 29.05.2021 
run stop:   20:33:33 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  549  
 | 
Sat May 29 20:35:22 2021 | 
Sophia, Mario | Runs | Run 0200 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0200.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  20:33:36 29.05.2021 
run stop:   20:45:12 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  550  
 | 
Sat May 29 21:37:54 2021 | 
Sophia, Mario | Runs | Run 0201 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0201.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  21:01:17 29.05.2021 
run stop:   22:02:02 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  551  
 | 
Sat May 29 22:03:28 2021 | 
Sophia, Mario | Runs | Run 0202 | 2021 | 
No. of stacks: 10 00:52:43 
length SC10: 2x 5.5s  
bump ge01sq2f (sc10): -20 mm  
bump target   (sc10): -12.8 mm 
 
open file : e127b_run0202.lmd 
 
beam: 118Te52+ 
energy: 6 MeV/u 
cooler voltage:  
 
purpose:  
Fragment beam measurement (beating the record of rad. beam pg-measurement) 
 
Detector position (Si): -25 mm 
GE01DD1IG position (Scraper): +6.0 mm  
 
run start:  22:02:07 29.05.2021 
run stop:   22:24:21 29.05.2021  
_______________________________________________________________________________ 
 
ON Rates 
Si_ON_bdt:    ~ 0   Hz  
Xray_ON_bdt:  ~ 0 Hz 
BaF_OR:     --- 
 
Si voltage:          100.0 V   
Si leakage current:  380 nA 
 
 
SIS particles before:      2.7e9 (one shoot) 
ESR current at injection:  3.0e6 (stacked)     
ESR particles after decel.: not measurable 
Target ON density:          8.0E13  | 
| 
  570  
 | 
Mon May 31 14:38:33 2021 | 
Sophia | Calibration | Runlist for X-ray detector calibrations after the experiment | 2021 | 
The by Jacobus Swartz created table in entry 335 extended by the calibration after the experiment.  | 
| Attachment 1: Kopie_von_E127_Runlist-calibrations-4-3-1.xlsx
 | 
| 
  228  
 | 
Mon Mar 23 08:04:07 2020 | 
Shahab, Laszlo,Yury | Runs | run entry - run094 | 2020 | 
open file : run094
beam: 124Xe54+
energy: 10 MeV/u
purpose: data with TARGET ON and SCRAPER in scraping poisition--> We expect to cut the Rutherford for now on.
at the 3. shoot counting backwards from the end of this file the TARGET LEFT ON for the whole cycle --> got a burst of particles on the detector in 
Target ON Mode as well. --> CUT OUT THIS ONE 1min PHASE!
Detector position (Si): -27 mm
GE01DD1IG position (Scraper): 9 mm
run start at 08:15, first file: run094_0001.lmd
run stop  at 08:17, last file:  run_094.lmd
_______________________________________________________________________________
time: 08:10
ON Rates
Si_X:       2 Hz
Si_Y:       2 Hz
Xray_35:    5 Hz
Xray_90:    84 Hz
Xray_145:   18 Hz
BaF_OR:     ---
Si voltage:          60.02 V  
Si leakage current:  4.32 uA
SIS particles before:           2.5e8
ESR current at injection:       4.5e7
ESR particles after decel.:     1e7
Target ON density:              3.8e13
copy and repeat the above (below the line) every 30 minutes  | 
| Attachment 1: 2020-03-23_08-13-00-443.png
 | 
 
 | 
| 
  229  
 | 
Mon Mar 23 08:20:31 2020 | 
Shahab, Laszlo,Yury | Runs | run entry - run095 |   | 
open file : run095
beam: 124Xe54+
energy: 10 MeV/u
purpose: data with TARGET ON and SCRAPER in scraping poisition--> We expect to cut the Rutherford for now on.
Detector position (Si): -27 mm
GE01DD1IG position (Scraper): 9 mm
run start at 08:17, first file: run095_0001.lmd
run stop  at , last file:  run_0xxx.lmd
_______________________________________________________________________________
time: 08:10
ON Rates
Si_X:       2 Hz
Si_Y:       2 Hz
Xray_35:    5 Hz
Xray_90:    84 Hz
Xray_145:   18 Hz
BaF_OR:     ---
Si voltage:          60.02 V  
Si leakage current:  4.32 uA
SIS particles before:           5.6e8
ESR current at injection:      
ESR particles after decel.:     ~8.64e6
Target ON density:              3.8e13
copy and repeat the above (below the line) every 30 minutes  | 
| Attachment 1: 2020-03-23_08-31-45-715.png
 | 
 
 |