|  Wed May 26 20:42:31 2021, Ragan, Thanassis, Runs, Run 0138, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target (sc10): -11.5 mm
 
 
 open file : e127b_run0138.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +1.0 mm
 
 run start: 20:42:13  26.05.2021
 run stop:  21:42:20  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 5 Hz
 Xray_ON_bdt: 100 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      7.0e8 (one shoot)
 ESR current at injection:  5.0e6 (stacked)
 ESR particles after decel.: 2.3e5 (more or less)
 Target ON density:          1.0e14
 | 
|  Wed May 26 20:34:50 2021, Ragan, Thanassis, Detectors, Detector filling, 2021 | 
| Jan is filling the detector after run0137. | 
|  Wed May 26 20:26:15 2021, Ragan, Thanassis, Runs, Run 0137, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target (sc10): -11.5 mm
 
 
 open file : e127b_run0137.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +1.0 mm (20mm away from beam)
 
 run start: 20:25:44  26.05.2021
 run stop:  20:33:11  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 6 Hz
 Xray_ON_bdt: 100 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      7.0e8 (one shoot)
 ESR current at injection:  5.0e6 (stacked)
 ESR particles after decel.: 2.3e5 (more or less)
 Target ON density:          1.0e14
 | 
|  Wed May 26 19:25:54 2021, Ragan, Thanassis, Runs, Run 0136, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target (sc10): -11.5 mm
 
 open file : e127b_run0136.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +1.0 mm (20mm away from beam)
 
 run start: 19:25:38  26.05.2021
 run stop:  20:25:40  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 6 Hz
 Xray_ON_bdt: 80 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.1e9 (one shoot)
 ESR current at injection:  5.4e6 (stacked)
 ESR particles after decel.: 0.9e6 (more or less)
 Target ON density:          1.0e14
 | 
|  Wed May 26 19:08:17 2021, Ragan, Thanassis, General, Cooler down, 2021 | 
| We stopped data taking as the electron cooler is down. | 
|  Wed May 26 18:37:34 2021, Ragan, Thanassis, General, Optimization target bump/overlapp, 2021 | 
| | bump position | X ray bdt ON | Si rate ON |
---------------------------------------------
| -11.5         | 120          | 4-5        |
| -10.5         | 100          | 5          |
| -9.5          | 85           | 5          |
| -12.5         | 100          | 6          |
-11.5 bump position is taken for the data taking. | 
|  Wed May 26 18:36:08 2021, Ragan, Thanassis, Runs, Run 0135, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target (sc10): -11.5 mm
 
 
 open file : e127b_run0135.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +1.0 mm (20mm away from beam)
 
 run start: 18:18:10  26.05.2021
 run stop:  19:07:37  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 6 Hz
 Xray_ON_bdt: 80 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.1e9 (one shoot)
 ESR current at injection:  5.4e6 (stacked)
 ESR particles after decel.: 0.9e6 (more or less)
 Target ON density:          1.0e14
 | 
|  Wed May 26 15:30:03 2021, Ragan, Thanassis, General, Changing the beam energy , 2021 | 
| The ESR team is changing the beam energy to 6 MeV/u. | 
|  Wed May 26 14:48:10 2021, Ragan, Thanassis, Runs, Run 0134, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target (sc10): -11.5 mm
 
 open file : e127b_run0134.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 14:47:22  26.05.2021
 run stop:  15:28:45  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 8 Hz
 Xray_ON_bdt: 210 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.1e9 (one shoot)
 ESR current at injection:  5.4e6 (stacked)
 ESR particles after decel.: 0.9e6 (more or less)
 Target ON density:          1.0e14
 | 
|  Wed May 26 14:28:23 2021, Jan, Analysis, Xrays from 118Te & 124Xe, 2021   | 
| Attached is a plot of the uncalibrated energy spectra taken with the 90 degree xray detector for 118Te (red) and 124Xe (blue).
Shown is the region covering the K-alpha and K-REC peaks.
Calculating the ratios (Te/Xe) for K_alpha and K-REC energies from theory one gets:
K_alpha (theory): 0.9236  
K-REC   (theory): 0.9308
Without energy calibration we get the following ratio (using channel numbers):
K_alpha (exp): 0.9293  
K-REC   (exp): 0.9344
Taking into account that the channel numbers are not calibrated, the agreement is still very good.
In summary we can be sure that we have 118Te stored at 7AMeV. | 
|  Wed May 26 13:49:36 2021, Rene, Tino, Runs, Run 0133, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0133.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 13:47:44  26.05.2021
 run stop:  14:47:12  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 8 Hz
 Xray_ON_bdt: 210 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.1e9 (one shoot)
 ESR current at injection:  5.4e6 (stacked)
 ESR particles after decel.: 0.9e6 (more or less)
 Target ON density:          1.0e14
 | 
|  Wed May 26 12:49:52 2021, Rene, Tino, Runs, Run 0132, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0132.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 12:49:29  26.05.2021
 run stop:  13:47:44  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 7 Hz
 Xray_ON_bdt: 280 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.1e8 (one shoot)
 ESR current at injection:  6.3e6 (stacked)
 ESR particles after decel.: 1.2e6 (more or less)
 Target ON density:          1.0e14
 
 Sensitivity of SIS trafo has been changed, thats why the the SIS particle number is smaller, but intensity did not change.
 Parallel injection into cave c has started. This brought problems with the timing for the stochastic cooling.
 | 
|  Wed May 26 11:47:48 2021, Rene, Tino, Runs, Run 0131, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0131.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 11:47:03  26.05.2021
 run stop:  12:49:17  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 7 Hz
 Xray_ON_bdt: 250 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      3.0e9 (one shoot)
 ESR current at injection:  6.3e6 (stacked)
 ESR particles after decel.: 1.2e6 (more or less)
 Target ON density:          1.0e14
 | 
|  Wed May 26 10:34:18 2021, Rene, Tino, Runs, Run 0130, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0130.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 10:33:13  26.05.2021
 run stop:  11:41:38  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 7 Hz
 Xray_ON_bdt: 240 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      1.9e9 (one shoot)
 ESR current at injection:  4.2e6 (stacked)
 ESR particles after decel.: 1.4e6 (more or less)
 Target ON density:          1.0e14
 
 electron cooler stopped working at the end of run. hence no target-on rate
 | 
|  Wed May 26 09:28:12 2021, Rene, Tino, Runs, Run 0129, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0129.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 9:27:53  26.05.2021
 run stop:  10:33:07  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 6 Hz
 Xray_ON_bdt: 270 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      1.9e9 (one shoot)
 ESR current at injection:  4.2e6 (stacked)
 ESR particles after decel.: 1.4e6 (more or less)
 Target ON density:          1.0e14
 
 First run with new filament, current still a little low
 | 
|  Wed May 26 07:20:14 2021, Rene, Tino, Runs, Run 0128, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0128.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 07:19:12  26.05.2021
 run stop:  08:30:54  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 7 Hz
 Xray_ON_bdt: 240 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      3.1e9 (one shoot)
 ESR current at injection:  6.4e6 (stacked)
 ESR particles after decel.: 0.9e6 (more or less)
 Target ON density:          1.0e14
 
 This run was a little longer, since we run until the filament needs to be changed
 | 
|  Wed May 26 07:08:07 2021, Laszlo, Calibration, quick and dirty calibration coefficients for the Si channels, 2021 | 
| The coefficients are produced only quick and dirty, S_x=1 was fixed to 1.
E = E_x = E_y = S_x*A_x = S_y*A_y
from 1-16: Si X channel
from 17-32: Si Y channel
S_param[1]=1;
S_param[2]=1.00953;
S_param[3]=1.00697;
S_param[4]=1.00506;
S_param[5]=0.985741;
S_param[6]=1.00338;
S_param[7]=0.998362;
S_param[8]=1.00424;
S_param[9]=0.998684;
S_param[10]=1.00029;
S_param[11]=1.01181;
S_param[12]=1.007;
S_param[13]=1.00927;
S_param[14]=1.00828;
S_param[15]=1.01399;
S_param[16]=0.995168;
S_param[17]=1.00612;
S_param[18]=1.01383;
S_param[19]=0.99964;
S_param[20]=1.03;
S_param[21]=1.00987;
S_param[22]=1.01913;
S_param[23]=0.993491;
S_param[24]=1.02393;
S_param[25]=1.00342;
S_param[26]=0.990515;
S_param[27]=0.986303;
S_param[28]=0.986874;
S_param[29]=1.00188;
S_param[30]=1.01761;
S_param[31]=0.995329;
S_param[32]=0.995247; | 
|  Wed May 26 06:27:18 2021, Michele, Beatriz, Runs, Run 0127, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0127.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 06:26:55  26.05.2021
 run stop:  07:18:24  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 3 Hz
 Xray_ON_bdt: 120 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.8e9 (one shoot)
 ESR current at injection:  5.8e6 (stacked)
 ESR particles after decel.: 1.4e6 (more or less)
 Target ON density:          1.0e14
 | 
|  Wed May 26 05:20:29 2021, Michele, Cobus, Runs, Run 0126, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0126.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 05:19:37  26.05.2021
 run stop:  06:26:39  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 2 Hz
 Xray_ON_bdt: 240 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.8e9 (one shoot)
 ESR current at injection:  6.5e6 (stacked)
 ESR particles after decel.: 1.5e6 (more or less)
 Target ON density:          1.0e14
 | 
|  Wed May 26 04:21:16 2021, Michele, Cobus, Runs, Run 0125, 2021 | 
| No. of stacks: 20 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0125.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 04:20:15  26.05.2021
 run stop:  05:19:30  26.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~ 2 Hz
 Xray_ON_bdt: 210 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.8e9 (one shoot)
 ESR current at injection:  5.5e6 (stacked)
 ESR particles after decel.: 1.7e6 (more or less)
 Target ON density:          1.0e14
 |