ID |
Date |
Author |
Category |
Subject |
Year |
479
|
Wed May 26 20:42:31 2021 |
Ragan, Thanassis | Runs | Run 0138 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0138.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm
run start: 20:42:13 26.05.2021
run stop: 21:42:20 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 5 Hz
Xray_ON_bdt: 100 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 7.0e8 (one shoot)
ESR current at injection: 5.0e6 (stacked)
ESR particles after decel.: 2.3e5 (more or less)
Target ON density: 1.0e14 |
478
|
Wed May 26 20:34:50 2021 |
Ragan, Thanassis | Detectors | Detector filling | 2021 |
Jan is filling the detector after run0137. |
477
|
Wed May 26 20:26:15 2021 |
Ragan, Thanassis | Runs | Run 0137 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0137.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm (20mm away from beam)
run start: 20:25:44 26.05.2021
run stop: 20:33:11 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 6 Hz
Xray_ON_bdt: 100 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 7.0e8 (one shoot)
ESR current at injection: 5.0e6 (stacked)
ESR particles after decel.: 2.3e5 (more or less)
Target ON density: 1.0e14 |
476
|
Wed May 26 19:25:54 2021 |
Ragan, Thanassis | Runs | Run 0136 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0136.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm (20mm away from beam)
run start: 19:25:38 26.05.2021
run stop: 20:25:40 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 6 Hz
Xray_ON_bdt: 80 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.1e9 (one shoot)
ESR current at injection: 5.4e6 (stacked)
ESR particles after decel.: 0.9e6 (more or less)
Target ON density: 1.0e14 |
475
|
Wed May 26 19:08:17 2021 |
Ragan, Thanassis | General | Cooler down | 2021 |
We stopped data taking as the electron cooler is down. |
474
|
Wed May 26 18:37:34 2021 |
Ragan, Thanassis | General | Optimization target bump/overlapp | 2021 |
| bump position | X ray bdt ON | Si rate ON |
---------------------------------------------
| -11.5 | 120 | 4-5 |
| -10.5 | 100 | 5 |
| -9.5 | 85 | 5 |
| -12.5 | 100 | 6 |
-11.5 bump position is taken for the data taking. |
473
|
Wed May 26 18:36:08 2021 |
Ragan, Thanassis | Runs | Run 0135 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0135.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm (20mm away from beam)
run start: 18:18:10 26.05.2021
run stop: 19:07:37 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 6 Hz
Xray_ON_bdt: 80 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.1e9 (one shoot)
ESR current at injection: 5.4e6 (stacked)
ESR particles after decel.: 0.9e6 (more or less)
Target ON density: 1.0e14 |
471
|
Wed May 26 15:30:03 2021 |
Ragan, Thanassis | General | Changing the beam energy | 2021 |
The ESR team is changing the beam energy to 6 MeV/u. |
470
|
Wed May 26 14:48:10 2021 |
Ragan, Thanassis | Runs | Run 0134 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0134.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 14:47:22 26.05.2021
run stop: 15:28:45 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 8 Hz
Xray_ON_bdt: 210 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.1e9 (one shoot)
ESR current at injection: 5.4e6 (stacked)
ESR particles after decel.: 0.9e6 (more or less)
Target ON density: 1.0e14 |
469
|
Wed May 26 14:28:23 2021 |
Jan | Analysis | Xrays from 118Te & 124Xe | 2021 |
Attached is a plot of the uncalibrated energy spectra taken with the 90 degree xray detector for 118Te (red) and 124Xe (blue).
Shown is the region covering the K-alpha and K-REC peaks.
Calculating the ratios (Te/Xe) for K_alpha and K-REC energies from theory one gets:
K_alpha (theory): 0.9236
K-REC (theory): 0.9308
Without energy calibration we get the following ratio (using channel numbers):
K_alpha (exp): 0.9293
K-REC (exp): 0.9344
Taking into account that the channel numbers are not calibrated, the agreement is still very good.
In summary we can be sure that we have 118Te stored at 7AMeV. |
468
|
Wed May 26 13:49:36 2021 |
Rene, Tino | Runs | Run 0133 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm (before -10 mm)
open file : e127b_run0133.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 13:47:44 26.05.2021
run stop: 14:47:12 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 8 Hz
Xray_ON_bdt: 210 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.1e9 (one shoot)
ESR current at injection: 5.4e6 (stacked)
ESR particles after decel.: 0.9e6 (more or less)
Target ON density: 1.0e14 |
467
|
Wed May 26 12:49:52 2021 |
Rene, Tino | Runs | Run 0132 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm (before -10 mm)
open file : e127b_run0132.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 12:49:29 26.05.2021
run stop: 13:47:44 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 7 Hz
Xray_ON_bdt: 280 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.1e8 (one shoot)
ESR current at injection: 6.3e6 (stacked)
ESR particles after decel.: 1.2e6 (more or less)
Target ON density: 1.0e14
Sensitivity of SIS trafo has been changed, thats why the the SIS particle number is smaller, but intensity did not change.
Parallel injection into cave c has started. This brought problems with the timing for the stochastic cooling. |
466
|
Wed May 26 11:47:48 2021 |
Rene, Tino | Runs | Run 0131 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm (before -10 mm)
open file : e127b_run0131.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 11:47:03 26.05.2021
run stop: 12:49:17 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 7 Hz
Xray_ON_bdt: 250 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 3.0e9 (one shoot)
ESR current at injection: 6.3e6 (stacked)
ESR particles after decel.: 1.2e6 (more or less)
Target ON density: 1.0e14 |
465
|
Wed May 26 10:34:18 2021 |
Rene, Tino | Runs | Run 0130 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm (before -10 mm)
open file : e127b_run0130.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 10:33:13 26.05.2021
run stop: 11:41:38 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 7 Hz
Xray_ON_bdt: 240 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 1.9e9 (one shoot)
ESR current at injection: 4.2e6 (stacked)
ESR particles after decel.: 1.4e6 (more or less)
Target ON density: 1.0e14
electron cooler stopped working at the end of run. hence no target-on rate |
464
|
Wed May 26 09:28:12 2021 |
Rene, Tino | Runs | Run 0129 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm (before -10 mm)
open file : e127b_run0129.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 9:27:53 26.05.2021
run stop: 10:33:07 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 6 Hz
Xray_ON_bdt: 270 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 1.9e9 (one shoot)
ESR current at injection: 4.2e6 (stacked)
ESR particles after decel.: 1.4e6 (more or less)
Target ON density: 1.0e14
First run with new filament, current still a little low |
463
|
Wed May 26 07:20:14 2021 |
Rene, Tino | Runs | Run 0128 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm (before -10 mm)
open file : e127b_run0128.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 07:19:12 26.05.2021
run stop: 08:30:54 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 7 Hz
Xray_ON_bdt: 240 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 3.1e9 (one shoot)
ESR current at injection: 6.4e6 (stacked)
ESR particles after decel.: 0.9e6 (more or less)
Target ON density: 1.0e14
This run was a little longer, since we run until the filament needs to be changed |
462
|
Wed May 26 07:08:07 2021 |
Laszlo | Calibration | quick and dirty calibration coefficients for the Si channels | 2021 |
The coefficients are produced only quick and dirty, S_x=1 was fixed to 1.
E = E_x = E_y = S_x*A_x = S_y*A_y
from 1-16: Si X channel
from 17-32: Si Y channel
S_param[1]=1;
S_param[2]=1.00953;
S_param[3]=1.00697;
S_param[4]=1.00506;
S_param[5]=0.985741;
S_param[6]=1.00338;
S_param[7]=0.998362;
S_param[8]=1.00424;
S_param[9]=0.998684;
S_param[10]=1.00029;
S_param[11]=1.01181;
S_param[12]=1.007;
S_param[13]=1.00927;
S_param[14]=1.00828;
S_param[15]=1.01399;
S_param[16]=0.995168;
S_param[17]=1.00612;
S_param[18]=1.01383;
S_param[19]=0.99964;
S_param[20]=1.03;
S_param[21]=1.00987;
S_param[22]=1.01913;
S_param[23]=0.993491;
S_param[24]=1.02393;
S_param[25]=1.00342;
S_param[26]=0.990515;
S_param[27]=0.986303;
S_param[28]=0.986874;
S_param[29]=1.00188;
S_param[30]=1.01761;
S_param[31]=0.995329;
S_param[32]=0.995247; |
461
|
Wed May 26 06:27:18 2021 |
Michele, Beatriz | Runs | Run 0127 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm (before -10 mm)
open file : e127b_run0127.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 06:26:55 26.05.2021
run stop: 07:18:24 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 3 Hz
Xray_ON_bdt: 120 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.8e9 (one shoot)
ESR current at injection: 5.8e6 (stacked)
ESR particles after decel.: 1.4e6 (more or less)
Target ON density: 1.0e14 |
460
|
Wed May 26 05:20:29 2021 |
Michele, Cobus | Runs | Run 0126 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm (before -10 mm)
open file : e127b_run0126.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 05:19:37 26.05.2021
run stop: 06:26:39 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 2 Hz
Xray_ON_bdt: 240 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.8e9 (one shoot)
ESR current at injection: 6.5e6 (stacked)
ESR particles after decel.: 1.5e6 (more or less)
Target ON density: 1.0e14 |
459
|
Wed May 26 04:21:16 2021 |
Michele, Cobus | Runs | Run 0125 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm (before -10 mm)
open file : e127b_run0125.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 04:20:15 26.05.2021
run stop: 05:19:30 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 2 Hz
Xray_ON_bdt: 210 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.8e9 (one shoot)
ESR current at injection: 5.5e6 (stacked)
ESR particles after decel.: 1.7e6 (more or less)
Target ON density: 1.0e14 |