| ID | Date | Author | Category | Subject | Year | 
| 418 | Mon May 24 13:14:59 2021 | Sophia, Mario | Runs | Run 0093 | 2021 | 
| No. of stacks: 5 length SC10: 2x 5.5s
 
 open file : e127b_run0093.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 13:14:44 24.05.2021
 run stop:  14:10:55 24.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    0 Hz
 Xray_ON_bdt: 0  Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      7.6e8
 ESR current at injection:  1e6 (stacked)
 ESR particles after decel.: 4e6
 Target ON density:          1.0e14
 | 
| 417 | Mon May 24 12:29:20 2021 | Sophia, Mario | Runs | Run 0092 | 2021 | 
| 20 stacks now 
 open file : e127b_run0092.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 12:28:57 24.05.2021
 run stop:  13:13:56 24.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    0 Hz
 Xray_ON_bdt: 0  Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      7.6e8
 ESR current at injection:  1e6 (stacked)
 ESR particles after decel.: 4e6
 Target ON density:          1.0e14
 | 
| 416 | Mon May 24 11:25:46 2021 | Sophia, Mario | Runs | Run 0091 | 2021 | 
| open file : e127b_run0091.lmd 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 11:25:08 25.05.2021
 run stop:  12:26:31 24.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    0 Hz
 Xray_ON_bdt: 0  Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      7.6e8
 ESR current at injection:  1e6 (stacked)
 ESR particles after decel.: 4e6
 Target ON density:          1.0e14
 | 
| 415 | Mon May 24 11:12:38 2021 | Sophia, Mario | Runs | Run 0090 | 2021 | 
| DAQ node 2 was not started! 
 
 open file : e127b_run0090.lmd
 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 11:10:18 23.05.2021
 run stop:
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    0 Hz
 Xray_ON_bdt: 0  Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      7.6e8
 ESR current at injection:  1e6 (stacked)
 ESR particles after decel.: 4e6
 Target ON density:          1.0e14
 | 
| 414 | Mon May 24 06:30:42 2021 | Ragan | DAQ | NTCAP | 2021 | 
| NTCAP started for recording Schottky data
SC_2021-05-24_06-29-31
\IQ_2021-05-24_06-29-31
Reference level: -30 dBm
Carrier frequency: 245 M
IQ Rate: 20 MS/s
RF attenuation (dB): 40
IF attenuation (dB): 19.9288
masterpath:
o:\E143\iq
ESR settings:
We recorded 3-4 full cycles with 5 stacks.
Then we recorded in SC5 manipulation for 10 min and afterwards in SC3 manipulation for 10 min. | 
| 413 | Mon May 24 05:20:36 2021 | Helmut, Yuri, Faraz, Sergey | Accelerator | FRS setup | 2021 | 
| Logbook from start of FRS until 118Te injection | 
| 412 | Sun May 23 23:44:37 2021 | Jan | Runs | Run 0088 - background BaF/Xray | 2021 | 
| open file : e127b_run0088.lmd 
 no beam
 
 purpose:
 BG  measurement for Xray and BaF
 
 run start: 23:44:09 23.05.2021
 run stop:
 _______________________________________________________________________________
 
 ON Rates
 Si_OFF_bdt:     Hz
 Xray_ON_bdt:  60Hz
 BaF_OR:     3000Hz
 | 
| 411 | Sun May 23 15:36:10 2021 | Rui-Jiu Chen& Alex | General | All shifts until Monday morning (24th May) have been cancelled. | 2021 | 
| All shifts until Monday morning (24th May) have been cancelled. 
Next update on further situation (in particular concerning the morning shift on Monday) will be given tonight . | 
| 410 | Sun May 23 07:40:48 2021 | Michele, Beatriz | Runs | Run 0087 | 2021 | 
| open file : e127b_run0086.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start: 07:40:25 23.05.2021
 run stop:  08:07:46 23.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    12 Hz
 Xray_ON_bdt: 600  Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      3.3e7
 ESR current at injection:  1.0e7
 ESR particles after decel.: 2.5e6
 Target ON density:          1.0e14
 | 
| 409 | Sun May 23 06:33:46 2021 | Philipp, Benny | Runs | Run 0086 | 2021 | 
| open file : e127b_run0086.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start: 06:33:41 23.05.2021
 run stop:  07:39:40 23.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    15 Hz
 Xray_ON_bdt:  800 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      2.8e7
 ESR current at injection:  1.3e7
 ESR particles after decel.: 2.2e6
 Target ON density:          1.0e14
 | 
| 408 | Sun May 23 05:35:07 2021 | Philipp, Benny | Runs | Run 0085 | 2021 | 
| open file : e127b_run0085.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start: 05:35:04 23.05.2021
 run stop:   06:33:22 23.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    10 Hz
 Xray_ON_bdt:  600 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      3.8e7
 ESR current at injection:  1.3e7
 ESR particles after decel.: 2.0e6
 Target ON density:          1.0e14
 | 
| 407 | Sun May 23 04:36:15 2021 | Philipp, Benny | Runs | Run 0084 | 2021 | 
| open file : e127b_run0084.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start: 04:36:12 23.05.2021
 run stop:   05:34:45 23.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    10 Hz
 Xray_ON_bdt:  600 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      bug in display
 ESR current at injection:  1.2e7
 ESR particles after decel.: 3.0e6
 Target ON density:          1.0e14
 | 
| 406 | Sun May 23 03:34:44 2021 | Philipp, Benny | Runs | Run 0083 | 2021 | 
| open file : e127b_run0083.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start: 03:34:50 23.05.2021
 run stop:  04:35:42 23.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    12 Hz
 Xray_ON_bdt:  600 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      bug in display
 ESR current at injection:  1e7
 ESR particles after decel.: 2.5e6
 Target ON density:          1.0e14
 | 
| 405 | Sun May 23 02:36:07 2021 | Philipp, Benny | Runs | Run 0082 | 2021 | 
| open file : e127b_run0082.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start: 02:36:02  23.05.2021
 run stop:  03:34:08 23.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    12 Hz
 Xray_ON_bdt:  600 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      4.5e7
 ESR current at injection:  8e6
 ESR particles after decel.: 2.5e6
 Target ON density:          1.0e14
 | 
| 404 | Sun May 23 02:16:47 2021 | Laszlo | General | quick comparison between different scraping positions | 2021 | 
| So far we did 3 scraping positions:
- 30mm away from beam axis (lmd72-75)
- 25mm away from beam axis (lmd78-80)
- 20mm away from beam axis (lmd76-77)
below one can see the comparison of the scrapings for the DSSSD spectrum. Please mind the different amount of data collected | 
| 403 | Sun May 23 01:36:04 2021 | Philipp, Benny | Runs | Run 0081 | 2021 | 
| open file : e127b_run0081.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start: 01:36:06  23.05.2021
 run stop:  02:35:37 23.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    12 Hz
 Xray_ON_bdt:  650 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      5.5e7
 ESR current at injection:  1.2e7
 ESR particles after decel.: 2.2e6
 Target ON density:          1.0e14
 | 
| 402 | Sun May 23 00:35:33 2021 | Philipp, Benny | Runs | Run 0080 | 2021 | 
| open file : e127b_run0080.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start:  00:35:16 23.05.2021
 run stop:  01:35:21 23.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    12 Hz
 Xray_ON_bdt:  650 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      xxxxx scaling problem, value negative, seem to be a visual problem only
 ESR current at injection:  1.6e7
 ESR particles after decel.: 2e6
 Target ON density:          1.0e14
 | 
| 401 | Sat May 22 23:28:08 2021 | Philipp, Benny | Runs | Run 0079 | 2021 | 
| open file : e127b_run0079.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start:  23:35:43 22.05.2021
 run stop: 00:34:46 23.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    12 Hz
 Xray_ON_bdt:  650 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      1e8
 ESR current at injection:  3.5e7
 ESR particles after decel.: 3e6
 Target ON density:          1.0e14
 | 
| 400 | Sat May 22 22:29:48 2021 | Laszlo, Pierre.Michel, Enis | General | new scraper position | 2021 | 
| The scraper was moved into 7.5 mm in absolute which corresponds to 25 mm away from the beam axis.
Pressluft Antriebe
Position 1
GE01DD1IG (SC12) 7.5 mm
Position 2
GE01DD1IG (SC9) 7.5 mm | 
| 399 | Sat May 22 22:25:42 2021 | Pierre-Michel & Enis | Runs | Run 0078 | 2021 | 
| open file : e127b_run0078.lmd 
 beam: 124Xe54+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Reference  measurement with scraper
 
 Detector position (Si): -19 mm
 GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
 
 run start: 22:25:23 22-05-2021
 run stop: 23:27:16 22-05-2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    15 Hz
 Xray_ON_bdt:  700 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  340 uA
 
 
 SIS particles before:      9e7
 ESR current at injection:  2.2e7
 ESR particles after decel.: 2.5e6
 Target ON density:          1.0e14
 
 Info: Dipole MU2 did no longer work, reset during the run, tried to reset at 23:12 Uhr. Problem not solved at the end of the run. Problematic injection structure
 |