ID |
Date |
Author |
Category |
Subject |
Year |
418
|
Mon May 24 13:14:59 2021 |
Sophia, Mario | Runs | Run 0093 | 2021 |
No. of stacks: 5
length SC10: 2x 5.5s
open file : e127b_run0093.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 13:14:44 24.05.2021
run stop: 14:10:55 24.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 0 Hz
Xray_ON_bdt: 0 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 7.6e8
ESR current at injection: 1e6 (stacked)
ESR particles after decel.: 4e6
Target ON density: 1.0e14 |
417
|
Mon May 24 12:29:20 2021 |
Sophia, Mario | Runs | Run 0092 | 2021 |
20 stacks now
open file : e127b_run0092.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 12:28:57 24.05.2021
run stop: 13:13:56 24.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 0 Hz
Xray_ON_bdt: 0 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 7.6e8
ESR current at injection: 1e6 (stacked)
ESR particles after decel.: 4e6
Target ON density: 1.0e14 |
416
|
Mon May 24 11:25:46 2021 |
Sophia, Mario | Runs | Run 0091 | 2021 |
open file : e127b_run0091.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 11:25:08 25.05.2021
run stop: 12:26:31 24.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 0 Hz
Xray_ON_bdt: 0 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 7.6e8
ESR current at injection: 1e6 (stacked)
ESR particles after decel.: 4e6
Target ON density: 1.0e14 |
415
|
Mon May 24 11:12:38 2021 |
Sophia, Mario | Runs | Run 0090 | 2021 |
DAQ node 2 was not started!
open file : e127b_run0090.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 11:10:18 23.05.2021
run stop:
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 0 Hz
Xray_ON_bdt: 0 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 7.6e8
ESR current at injection: 1e6 (stacked)
ESR particles after decel.: 4e6
Target ON density: 1.0e14 |
414
|
Mon May 24 06:30:42 2021 |
Ragan | DAQ | NTCAP | 2021 |
NTCAP started for recording Schottky data
SC_2021-05-24_06-29-31
\IQ_2021-05-24_06-29-31
Reference level: -30 dBm
Carrier frequency: 245 M
IQ Rate: 20 MS/s
RF attenuation (dB): 40
IF attenuation (dB): 19.9288
masterpath:
o:\E143\iq
ESR settings:
We recorded 3-4 full cycles with 5 stacks.
Then we recorded in SC5 manipulation for 10 min and afterwards in SC3 manipulation for 10 min. |
413
|
Mon May 24 05:20:36 2021 |
Helmut, Yuri, Faraz, Sergey | Accelerator | FRS setup | 2021 |
Logbook from start of FRS until 118Te injection |
Attachment 1: IMG_20210524_050643.jpg
|
|
Attachment 2: IMG_20210524_050651.jpg
|
|
Attachment 3: IMG_20210524_050658.jpg
|
|
Attachment 4: IMG_20210524_050705.jpg
|
|
Attachment 5: IMG_20210524_050712.jpg
|
|
Attachment 6: IMG_20210524_050718.jpg
|
|
Attachment 7: IMG_20210524_050725.jpg
|
|
Attachment 8: IMG_20210524_050732.jpg
|
|
Attachment 9: IMG_20210524_050739.jpg
|
|
Attachment 10: IMG_20210524_050748.jpg
|
|
Attachment 11: IMG_20210524_050759.jpg
|
|
Attachment 12: IMG_20210524_050805.jpg
|
|
Attachment 13: IMG_20210524_050811.jpg
|
|
Attachment 14: IMG_20210524_050818.jpg
|
|
412
|
Sun May 23 23:44:37 2021 |
Jan | Runs | Run 0088 - background BaF/Xray | 2021 |
open file : e127b_run0088.lmd
no beam
purpose:
BG measurement for Xray and BaF
run start: 23:44:09 23.05.2021
run stop:
_______________________________________________________________________________
ON Rates
Si_OFF_bdt: Hz
Xray_ON_bdt: 60Hz
BaF_OR: 3000Hz |
411
|
Sun May 23 15:36:10 2021 |
Rui-Jiu Chen& Alex | General | All shifts until Monday morning (24th May) have been cancelled. | 2021 |
All shifts until Monday morning (24th May) have been cancelled.
Next update on further situation (in particular concerning the morning shift on Monday) will be given tonight . |
410
|
Sun May 23 07:40:48 2021 |
Michele, Beatriz | Runs | Run 0087 | 2021 |
open file : e127b_run0086.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 07:40:25 23.05.2021
run stop: 08:07:46 23.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 12 Hz
Xray_ON_bdt: 600 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 3.3e7
ESR current at injection: 1.0e7
ESR particles after decel.: 2.5e6
Target ON density: 1.0e14 |
409
|
Sun May 23 06:33:46 2021 |
Philipp, Benny | Runs | Run 0086 | 2021 |
open file : e127b_run0086.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 06:33:41 23.05.2021
run stop: 07:39:40 23.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 15 Hz
Xray_ON_bdt: 800 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 2.8e7
ESR current at injection: 1.3e7
ESR particles after decel.: 2.2e6
Target ON density: 1.0e14 |
408
|
Sun May 23 05:35:07 2021 |
Philipp, Benny | Runs | Run 0085 | 2021 |
open file : e127b_run0085.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 05:35:04 23.05.2021
run stop: 06:33:22 23.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 10 Hz
Xray_ON_bdt: 600 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 3.8e7
ESR current at injection: 1.3e7
ESR particles after decel.: 2.0e6
Target ON density: 1.0e14 |
407
|
Sun May 23 04:36:15 2021 |
Philipp, Benny | Runs | Run 0084 | 2021 |
open file : e127b_run0084.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 04:36:12 23.05.2021
run stop: 05:34:45 23.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 10 Hz
Xray_ON_bdt: 600 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: bug in display
ESR current at injection: 1.2e7
ESR particles after decel.: 3.0e6
Target ON density: 1.0e14 |
406
|
Sun May 23 03:34:44 2021 |
Philipp, Benny | Runs | Run 0083 | 2021 |
open file : e127b_run0083.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 03:34:50 23.05.2021
run stop: 04:35:42 23.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 12 Hz
Xray_ON_bdt: 600 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: bug in display
ESR current at injection: 1e7
ESR particles after decel.: 2.5e6
Target ON density: 1.0e14 |
405
|
Sun May 23 02:36:07 2021 |
Philipp, Benny | Runs | Run 0082 | 2021 |
open file : e127b_run0082.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 02:36:02 23.05.2021
run stop: 03:34:08 23.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 12 Hz
Xray_ON_bdt: 600 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 4.5e7
ESR current at injection: 8e6
ESR particles after decel.: 2.5e6
Target ON density: 1.0e14 |
404
|
Sun May 23 02:16:47 2021 |
Laszlo | General | quick comparison between different scraping positions | 2021 |
So far we did 3 scraping positions:
- 30mm away from beam axis (lmd72-75)
- 25mm away from beam axis (lmd78-80)
- 20mm away from beam axis (lmd76-77)
below one can see the comparison of the scrapings for the DSSSD spectrum. Please mind the different amount of data collected |
Attachment 1: scraping_30.png
|
|
Attachment 2: scraping_25.png
|
|
Attachment 3: scraping_20.png
|
|
403
|
Sun May 23 01:36:04 2021 |
Philipp, Benny | Runs | Run 0081 | 2021 |
open file : e127b_run0081.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 01:36:06 23.05.2021
run stop: 02:35:37 23.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 12 Hz
Xray_ON_bdt: 650 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 5.5e7
ESR current at injection: 1.2e7
ESR particles after decel.: 2.2e6
Target ON density: 1.0e14 |
402
|
Sun May 23 00:35:33 2021 |
Philipp, Benny | Runs | Run 0080 | 2021 |
open file : e127b_run0080.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 00:35:16 23.05.2021
run stop: 01:35:21 23.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 12 Hz
Xray_ON_bdt: 650 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: xxxxx scaling problem, value negative, seem to be a visual problem only
ESR current at injection: 1.6e7
ESR particles after decel.: 2e6
Target ON density: 1.0e14 |
401
|
Sat May 22 23:28:08 2021 |
Philipp, Benny | Runs | Run 0079 | 2021 |
open file : e127b_run0079.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 23:35:43 22.05.2021
run stop: 00:34:46 23.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 12 Hz
Xray_ON_bdt: 650 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 1e8
ESR current at injection: 3.5e7
ESR particles after decel.: 3e6
Target ON density: 1.0e14 |
400
|
Sat May 22 22:29:48 2021 |
Laszlo, Pierre.Michel, Enis | General | new scraper position | 2021 |
The scraper was moved into 7.5 mm in absolute which corresponds to 25 mm away from the beam axis.
Pressluft Antriebe
Position 1
GE01DD1IG (SC12) 7.5 mm
Position 2
GE01DD1IG (SC9) 7.5 mm |
399
|
Sat May 22 22:25:42 2021 |
Pierre-Michel & Enis | Runs | Run 0078 | 2021 |
open file : e127b_run0078.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement with scraper
Detector position (Si): -19 mm
GE01DD1IG position (Scraper): +7.5 mm (25mm away from beam)
run start: 22:25:23 22-05-2021
run stop: 23:27:16 22-05-2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 15 Hz
Xray_ON_bdt: 700 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 9e7
ESR current at injection: 2.2e7
ESR particles after decel.: 2.5e6
Target ON density: 1.0e14
Info: Dipole MU2 did no longer work, reset during the run, tried to reset at 23:12 Uhr. Problem not solved at the end of the run. Problematic injection structure |