  229   Thu Apr 14 12:38:38 2022 SebastianDetectorsXUV / Cu checkupsCheck regularly if the connection to the XUV
and Cu detectors are still active and the
detectors move in (after injection) and out
  
  129   Thu Apr 7 05:55:17 2022 Ken UeberholzDetectorsXUV-Detector Mesytec crashWhen the XUV-detector has to shut down unexpectedly,
it can happen that the Mesytek power supply
crashes and can't be 
  
  84   Wed Mar 24 06:22:05 156 Ken UeberholzDetectorsXUV-Detector RatesCount rates were measured for the XUV-
detector for a full circle:
Cathode: -5V, shields: 0V, main coil 8A,
 Screenshot_20220404-000343_Gallery.jpgScreenshot_20220404-000327_Gallery.jpgScreenshot_20220404-000411_Gallery.jpg 
  81   Sun Apr 3 15:34:34 2022 Ken Ueberholz  Xuv-Detektor CFD-treshholdI co controlled all detector signals and 
adjusted the threshold to be just above 
the noise. I will double check this when
  
  73   Sun Apr 3 00:41:45 2022 Ken Ueberholz  Xuv-Detektor Signale The Xuv-detector cabel channels seem to be

wrongly labeled in the Messhütte (see 
 20220403_004944.jpg 
  116   Wed Apr 6 21:03:25 2022 Ken Ueberholz DetectorsXuv-Detektor, further information Some further information regarding the 
xuv-detector and its components.
 xuv_detektor.pdf 
  197   Sun Apr 10 11:11:18 2022 Kristian, MaxLaseradditional WM readoutsince the WM readout still does not work reliably,
I started a python script at atppc023 that
saves timestamp and wavemeter frequency.
  
  132   Thu Apr 7 08:43:19 2022 Danyal, Yuri, RaganAcceleratoragain no injection in ESR - ESR kicker problemwe had no injections in the ESR again 

it turned out that the injection kicker of
  
  15   Thu Mar 10 15:20:26 2022 Jan DAQanalog branch signal patches to Messhütte The additional signals from PMTs and XUV detector
needed for spectroscopic analysis in the
second DAQ are patched to AP Messhütte (MH)
 red_panel_ESR.jpgpulser_signal_ESR.jpgpulser_signal_MH.jpgdelay_ESR-MH-ESR.jpgcable_bundle_mirror_chamber.jpg 
  5   Fri Aug 6 10:23:00 2021 RodolfoDAQatplaser on r4l-41The user [B]atplaser[/B] is now existing on
the [B]R4L-XY[/B] nodes for the ESR group.
  
  94   Tue Apr 5 09:45:47 2022 Danyal & YuriAcceleratorbeam is back in the ESR - a slit was moved inAnd now also in English :) 

The ion beam is back in the ESR! 
  
  234   Fri Apr 15 12:53:25 2022 Max, DanyalLaserchecked laser pulse energy after change in wavelength rangeprevious scan range: 
the laser pulse energy @ 320.62 nm  was ~11
mJ 
  
  99   Tue Apr 5 14:51:51 2022 KristianDAQdark countsWe shielded the PMTs, i.e., the N2 tube, which
improved the Cu PMT background rate.
  
  136   Thu Apr 7 11:11:31 2022 Max, SebastianLaserdye changed, pulse energy measurementsWe changed the dye at 10am.

We increased the pump power for the dye Laser
  
  166   Fri Apr 8 15:39:36 2022 allRunsfirst data after timing set upstarted taking data again

started at 15:40  
  
  183   Sat Apr 9 13:45:42 2022 Max, KristianRunsfirst scans with LV problem solved!This is the first time with LV buffer problem
solved (see Elog ID: 184). Before the PMT
signals were out of sync with the wavelength
  
  192   Sun Apr 10 04:07:53 2022 PatrickDAQgo4 shows wrong frequencies and wavelengths[B]Update (ID:194):[/B] In labview "Stop All",
close labview, stop python script (ID:197),
close wavemeter. Then restart wavemeter,
 2022-04-10_measured_wavel.png2022-04-10_measured_wavel2.png2022-04-10_measured_wavel_go4.png 
  165   Fri Apr 8 14:46:02 2022 Danyal & Sebastian & Volker & KenDetectorshigh dark countrate Cu PMT solvedThe problem - "discovered" by Volker and Ken
- of the high dark countrate of the Cu PMT
has been solved. 
 IMG_20220408_082804.jpgIMG_20220408_083031.jpg 
  164   Fri Apr 8 14:43:50 2022 WilfriedDAQlaser timing - Q-switch startbelow are my notes concerning laser timing
/ Q-switch start
 IMG_20220408_143753_resized_20220408_023840170.jpg 
  233   Fri Apr 15 12:42:18 2022 Max, Danyal, Carsten, Konstantin, Patrick, SimonGenerallaser wavelength range changed: 320.12 - 319.60 nm
Runs of the morning/afternoon/night shift.
The wavelength range is now 320.12 - 319.60
 VoltageJump1830.PNG 