| ID | Date | Author  | Category | Subject | Text |  | 
| 28 | Wed Mar 23 11:20:55 2022 | Simon | Detectors | PMT operating voltages | During the testing of the PMTs the following operating voltages were applied:
 
 |  | 
| 77 | Sun Apr  3 11:40:48 2022 | Shahab, Yuri | Detectors | 245 MHz Resonator tuned to new frequency | resonance frequency changed from 243.2 MHz to 244.692 MHz by reducing the value of both
 of the plungers from 395 to 325. Now after
 |   | 
| 44 | Thu Mar 31 20:07:47 2022 | Shahab | DAQ | Schottky Display in AP Messhütte (or anywhere else) | [B]UPDATE: 16.05.2022[/B] 
 [I]Please use ATPPC029 instead of ATPPC019
 |   | 
| 137 | Thu Apr  7 14:01:22 2022 | Sebastian, Max | Detectors | Mesytec reset | The Mesytec crate was turned off and on again. 
 It is again possible to communicate with
 |  | 
| 228 | Thu Apr 14 12:27:18 2022 | Sebastian, Max | Detectors | Connection to XUV / Cu reestablished! | The connection to the XUV and Cu were lost during the nightshift.
 
 |  | 
| 95 | Tue Apr  5 11:14:52 2022 | Sebastian, Kristian, Pierre-Michel | DAQ | PMT over wavelength histogram v2 | Today we finalized the PMT over wavelength histogram in:
 
 |  | 
| 100 | Tue Apr  5 15:25:47 2022 | Sebastian, Kristian, Pierre-Michel | DAQ | Go4 Conditions for "TDC_stacked_Sig/Ref" histogram | First version of TDC_stacked histograms implemented. 
 Under folder "Conditions" you can now integrate
 |  | 
| 208 | Mon Apr 11 11:05:35 2022 | Sebastian, Kristian | Laser | Check laser power | we checked the UV laser power at 10:15 am. It was only 8.5 - 9 mJ. Pumping power was
 460 mJ, which is the maximum output of the
 |  | 
| 87 | Mon Apr  4 15:27:31 2022 | Sebastian | DAQ | PMT over wavelength histogram | Kristian and I tried to create a "PMT over wavelength" histogram under step2Anl/LabView.
 Unfortunately, the code ist still in progress
 |  | 
| 133 | Thu Apr  7 09:23:18 2022 | Sebastian | DAQ | DAQ1 & DAQ2 - 1kHz and delayed cs removed | Questionable 1kHz and delayed common stop signals has been removed.
 
 |  | 
| 152 | Fri Apr  8 08:17:52 2022 | Sebastian | Laser | Laser Ext Trig is working | We (Max, Kristian, Danyal, me) fixed the "external trigger" problem.
 
 |      | 
| 153 | Fri Apr  8 08:40:06 2022 | Sebastian | DAQ | DAQ improvement | Concerning ID 146 a new histogram for accumulating data (no cleaning histograms) can be found
 under
 |  | 
| 229 | Thu Apr 14 12:38:38 2022 | Sebastian | Detectors | XUV / Cu checkups | Check regularly if the connection to the XUV and Cu detectors are still active and the
 detectors move in (after injection) and out
 |  | 
| 231 | Thu Apr 14 19:46:46 2022 | Sarper & Konstantin & Rodolfo | Laser | Laser power | We checked the laser power before starting the new scan range.
 
 |  | 
| 78 | Sun Apr  3 12:31:10 2022 | Rui-Jiu Chen, Yuri, Carsten, Ragan | Runs | Measurement of beam with different circles | Parameters of NTCAP: 
 1. IQ rate 20 MSamples/s
 | 6x   | 
| 64 | Sat Apr  2 10:22:21 2022 | Rui-Jiu Chen, Ragan | General | Beam is in the ESR | Primary beam is in the ESR now. Markus and the team are tuning the ESR.
 |  | 
| 51 | Fri Apr  1 11:00:41 2022 | Rui-Jiu Chen | DAQ | Start NTCAP | Start taking data with NTCAP. Carrier Frequency: 245MHz
 IQ rate:5 MSamples/s
 |  | 
| 52 | Fri Apr  1 11:19:57 2022 | Rui-Jiu Chen | DAQ | S.M.A.R.T check on NTCAP | S.M.A.R.T. check has been done on NTCAP on March 28th. All 12 hard disk drivers  are
 normal.
 |   | 
| 211 | Mon Apr 11 18:46:31 2022 | Rodolfo, Sarper and Konstantin | Laser | Alignment-check | We cross-checked the laser-ion alignment. The horizontal position was optimized. However,
 
 |   | 
| 224 | Wed Apr 13 15:41:29 2022 | Rodolfo & Sarper | Laser | Laser status | We have checked the power of the laser and optimized it "a bit".
 
 |  |