  28   Wed Mar 23 11:20:55 2022 SimonDetectorsPMT operating voltagesDuring the testing of the PMTs the following
operating voltages were applied:
  
  77   Sun Apr 3 11:40:48 2022 Shahab, YuriDetectors245 MHz Resonator tuned to new frequencyresonance frequency changed from 243.2 MHz
to 244.692 MHz by reducing the value of both
of the plungers from 395 to 325. Now after
 Screenshot_2022-04-03_at_11.24.15.png 
  44   Thu Mar 31 20:07:47 2022 ShahabDAQSchottky Display in AP Messhütte (or anywhere else)[B]UPDATE: 16.05.2022[/B]

[I]Please use ATPPC029 instead of ATPPC019
 04_PM_schottky.png 
  137   Thu Apr 7 14:01:22 2022 Sebastian, MaxDetectorsMesytec resetThe Mesytec crate was turned off and on again.

It is again possible to communicate with
  
  228   Thu Apr 14 12:27:18 2022 Sebastian, MaxDetectorsConnection to XUV / Cu reestablished!The connection to the XUV and Cu were lost
during the nightshift.
  
  95   Tue Apr 5 11:14:52 2022 Sebastian, Kristian, Pierre-MichelDAQPMT over wavelength histogram v2Today we finalized the PMT over wavelength
histogram in:
  
  100   Tue Apr 5 15:25:47 2022 Sebastian, Kristian, Pierre-MichelDAQGo4 Conditions for "TDC_stacked_Sig/Ref" histogramFirst version of TDC_stacked histograms implemented.

Under folder "Conditions" you can now integrate
  
  208   Mon Apr 11 11:05:35 2022 Sebastian, KristianLaserCheck laser powerwe checked the UV laser power at 10:15 am.
It was only 8.5 - 9 mJ. Pumping power was
460 mJ, which is the maximum output of the
  
  87   Mon Apr 4 15:27:31 2022 SebastianDAQPMT over wavelength histogramKristian and I tried to create a "PMT over
wavelength" histogram under step2Anl/LabView.
Unfortunately, the code ist still in progress
  
  133   Thu Apr 7 09:23:18 2022 SebastianDAQDAQ1 & DAQ2 - 1kHz and delayed cs removedQuestionable 1kHz and delayed common stop
signals has been removed.
  
  152   Fri Apr 8 08:17:52 2022 SebastianLaserLaser Ext Trig is workingWe (Max, Kristian, Danyal, me) fixed the "external
trigger" problem.
 upperDualTimerSettings.JPGlowerDualTimerSettings.JPGLampSyncToQSwitchTrig.JPGTriggerPulseTrain.JPG 
  153   Fri Apr 8 08:40:06 2022 SebastianDAQDAQ improvementConcerning ID 146 a new histogram for accumulating
data (no cleaning histograms) can be found
under
  
  229   Thu Apr 14 12:38:38 2022 SebastianDetectorsXUV / Cu checkupsCheck regularly if the connection to the XUV
and Cu detectors are still active and the
detectors move in (after injection) and out
  
  231   Thu Apr 14 19:46:46 2022 Sarper & Konstantin & RodolfoLaserLaser powerWe checked the laser power before starting
the new scan range.
  
  78   Sun Apr 3 12:31:10 2022 Rui-Jiu Chen, Yuri, Carsten, RaganRunsMeasurement of beam with different circlesParameters of NTCAP:

  1. IQ rate 20 MSamples/s
 6x 
  64   Sat Apr 2 10:22:21 2022 Rui-Jiu Chen, RaganGeneralBeam is in the ESRPrimary beam is in the ESR now. Markus and
the team are tuning the ESR.
  
  51   Fri Apr 1 11:00:41 2022 Rui-Jiu ChenDAQStart NTCAPStart taking data with NTCAP.
Carrier Frequency: 245MHz
IQ rate:5 MSamples/s
  
  52   Fri Apr 1 11:19:57 2022 Rui-Jiu ChenDAQS.M.A.R.T check on NTCAPS.M.A.R.T. check has been done on NTCAP on
March 28th. All 12 hard disk drivers  are
normal.
 image001(04-01-11-10-06).jpg 
  211   Mon Apr 11 18:46:31 2022 Rodolfo, Sarper and KonstantinLaserAlignment-checkWe cross-checked the laser-ion alignment.
The horizontal position was optimized. However,
 MRC_Konfiguration_MitMainAmp_04-11-2022.png 
  224   Wed Apr 13 15:41:29 2022 Rodolfo & SarperLaserLaser statusWe have checked the power of the laser and
optimized it "a bit".
  