Here's a list of the spectra to look at for the potential isomer, taken btw 21:00 on July 2nd and 6:30 on July 3rd. Two examples attached.
Name Comment
410MHz-2021.07.02.21.18.54.456.tiq
410MHz-2021.07.02.21.27.19.948.tiq slightly different freq
410MHz-2021.07.02.21.33.07.438.tiq
410MHz-2021.07.02.21.42.36.139.tiq slightly different freq
410MHz-2021.07.02.21.52.04.801.tiq
410MHz-2021.07.02.22.03.37.550.tiq appears at ~3.5s
410MHz-2021.07.02.22.12.31.601.tiq slightly different freq
410MHz-2021.07.02.22.30.24.641.tiq slightly different freq
410MHz-2021.07.02.22.40.24.894.tiq triplet
410MHz-2021.07.02.23.04.38.838.tiq
410MHz-2021.07.03.01.00.29.856.tiq slightly different freq
410MHz-2021.07.03.01.29.59.709.tiq slightly different freq
410MHz-2021.07.03.01.45.47.532.tiq
410MHz-2021.07.03.01.47.22.303.tiq a bit more shifted to the left
410MHz-2021.07.03.01.54.44.606.tiq
410MHz-2021.07.03.02.14.45.610.tiq a bit more shifted to the left
410MHz-2021.07.03.02.28.58.637.tiq slightly different freq
410MHz-2021.07.03.02.55.49.838.tiq a bit more shifted to the left
410MHz-2021.07.03.03.15.50.713.tiq a bit more shifted to the left
410MHz-2021.07.03.03.55.52.357.tiq slightly different freq
410MHz-2021.07.03.03.56.55.568.tiq a bit more shifted to the left
410MHz-2021.07.03.01.11.33.702.tiq
410MHz-2021.07.03.01.20.31.004.tiq
410MHz-2021.07.03.00.07.18.136.tiq
410MHz-2021.07.03.00.42.04.236.tiq
410MHz-2021.07.03.00.45.45.337.tiq
410MHz-2021.07.03.04.22.44.303.tiq
410MHz-2021.07.03.04.26.25.486.tiq
410MHz-2021.07.03.04.45.54.495.tiq
410MHz-2021.07.03.04.49.35.705.tiq
410MHz-2021.07.03.05.25.24.517.tiq
410MHz-2021.07.03.05.58.03.370.tiq
410MHz-2021.07.03.06.19.07.475.tiq
----------------------------------------------
> After looking through >800 shots from Jul 2nd 21h to Jul 3rd 05h, we couldn't find a single example of a "smoking gun" isomer decay. I.e. I'm talking about the examples Liliana posted earlier. We did find many examples (roughly 10%) where the ion track spontaneously
> disappeared, but this shouldn't be the isomer as there was no frequency shift.
>
> We did, as Iris mentioned, observe some line "in-between" the broad peak unique to the 410MHz, and listed them here (https://triumfoffice365-my.sharepoint.com/:x:/g/personal/dillmann_triumf_ca/EdKsMfSC3AlHopA36PdLBlsBE2MCSY0hh5qIsuau5HFBmg?rtime=Z2os4J492Ug).
> I then proceeded to sum these files to see if they lined up. The result it attached, with the previous total sum from 21-00h Jul 2nd at the bottom for comparison. It seems the 70Se line has shifted, this is observed in the other shots too. However, despite the low
> statistics, these other shots don't line up with the broad peak identified before, although they don't line up well with each other individually either.
> In either case, we think these files might be worth offline analysis as they're the only possible hint of the 70Se isomer so far. |