HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  nuclear two-photon decay, Page 12 of 12  Not logged in ELOG logo
ID Date Author Categorydown Subject Text Attachments
  147   Wed Jun 30 08:59:37 2021 YuriAccelerator70Se settingX(9Be)=1.815 g/cm2 (adjusted in primary beam
setting)
  
  148   Wed Jun 30 09:04:50 2021 Yuri, MarkusAcceleratorStatus1) Over night the source was conservated.
It is being restarted now.
2) The approximated amount of Gas in this
  
  153   Wed Jun 30 13:57:14 2021 Yuri, SergeyAcceleratorsextupoles + scraper positionsAfter setting up on 70Se
Sextupoles were adjusted to optimize the
resolution of the 70Se peak. Set values are
 photo_2021-06-30_14-09-08.jpgphoto_2021-06-30_14-02-25.jpg 
  166   Thu Jul 1 07:28:55 2021 Jan, AkashAcceleratorBeam intensityIntensity went up from 5e8 to 1e9 extracted
particles from SIS.
  
  167   Thu Jul 1 14:47:15 2021 Yury, HelmutAcceleratoradded high Brho scrapersSo far only scrapers for low Brho were used:
  GE01DS_HI = -58mm (arc from inside) and
  GEEXDS2HA = -11.2 (straight from outside)
 ESR-scraper-overview.jpgscrapers-used.JPG 
  205   Fri Jul 2 11:44:25 2021 Helmut, YuriAcceleratormove scrapers to see effect on unknown linesWe close the arc inside and straight section
inside scrapers to narrow and cut the 70Se
line.
  
  206   Fri Jul 2 12:18:35 2021 Pavlos, AlexandreAcceleratore-coolingSergey Litvinov will now try to setup the
e-cooler to cool the beam in the ESR. 
The data taking has been stopped (except
  
  209   Fri Jul 2 13:10:00 2021 YuriAcceleratorScrapers12:46 moved the TOF detector scraper back
to -11 mm
  
  211   Fri Jul 2 13:44:50 2021 Sergey, et alAcceleratorEl coolerUp to now, attempts to cool the fat line between
Se and Ar were conducted. We give up it now
and remove cooling
  
  214   Fri Jul 2 16:14:17 2021 YuriAcceleratorScrapers 4 72BrStarting 15:15
The scrapers are moved very much close to
each other to eliminate all background particles
 1C28A49A-5FA1-4A81-8675-3ED9660FD793.png 
  220   Fri Jul 2 20:33:44 2021 YuriAccelerator70Se setting with closed scrapersWe tune back to 70Se.
The scrapers stay closed at EEXDS2HA=0 mm,
EEXDS1HG=+5 mm
  
ELOG V3.1.5-fc6679b