HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028
  nuclear two-photon decay, Page 4 of 12  Not logged in ELOG logo
ID Date Authordown Category Subject
  24   Fri May 7 01:49:03 2021 Rui-Jiu ChenDAQComparison of I_Raw/Q_Raw between different reference level
This is a comparison of I_Raw/Q_Raw between different reference level. The range of NTCAP ADC is only 2^15 bit. So signals (I_Raw and Q_Raw) should 
not be outside ADC range. It is clear that there is not point outside the ADC range when using reference level -30dBm.
  66   Sat May 8 03:05:42 2021 Rui-Jiu ChenDAQChange reference level to -60dBm
Start a new run. The data of new run is in :
SC_2021-05-07_17-33-29
IQ_2021-05-07_17-33-29
  67   Sat May 8 03:08:57 2021 Rui-Jiu ChenDAQChange reference level to -50dBm
Start a new run. The data of new run is in :
SC_2021-05-07_17-39-16
IQ_2021-05-07_17-39-16
  78   Sat May 8 18:35:25 2021 Rui-Jiu ChenDAQChange reference level to -10dBm
The beam in ESR is 78Kr36+@476 MeV/u.
Start a new run:
SC_2021-05-08_18-25-52
IQ_2021-05-08_18-25-52
  112   Sun May 9 20:34:47 2021 Rui-Jiu ChenAnalysisComparison of frequency spectrum between 72Ge and other isotope
This some preliminary analysis results by using  NTCAP data.   The IQ rate of NTCAP is 20 MSamples/seconds. I analyzed data files recorded from May 7 
17:39 to May 8 2:20.  The frequency of 72Ge is bended by 4kHz at the beginning of some injections.  In order to check whether this frequency bending is 
due to isomer or unstable magnetic field. I compare the 72Ge with other isotopes. The similar bending was observed for other isotope in each 
corresponding injections. It seems that bend is due to unstable magnetic field.  
  119   Sun May 9 23:59:26 2021 Rui-Jiu ChenDAQStart a new run.
Start a new run. The data of new run is in :
reference level = -50dBm.
SC_2021-05-09_23-43-37
IQ_2021-05-09_23-43-37
  121   Mon May 10 00:08:26 2021 Rui-Jiu ChenDAQChange reference level to -60dBm
Start a new run. The data of new run is in :
SC_2021-05-10_00-08-08
IQ_2021-05-10_00-08-08
  139   Tue Jun 29 20:40:55 2021 Rui-Jiu ChenDAQstart NTCAP
Carrier Frequency:245MHz.
IQ rate 20MSamples/s
Reference level:-90 dBm
SC_2021-06-29_20-38-27
IQ_2021-06-29_20-38-27
  143   Wed Jun 30 00:12:55 2021 Rui-Jiu ChenAnalysisthe ID of 72Ge setting
  144   Wed Jun 30 00:20:10 2021 Rui-Jiu ChenAnalysisID of 70Se setting on May
This is an old spectrum which was recoded on May.
  149   Wed Jun 30 12:26:58 2021 Rui-Jiu ChenAnalysisNTCAP start.
SC_2021-06-30_11-00-12
IQ_2021-06-30_11-00-12
reference level -80dBm.
Amplifier is off.
  150   Wed Jun 30 12:35:53 2021 Rui-Jiu ChenAnalysisChange reference level to -20dBm. Turn of amplifier.
SC_2021-06-30_12_35_52
IQ_2021-06-30_12_35_43
Reference level=-20dBm
  152   Wed Jun 30 13:05:08 2021 Rui-Jiu ChenAnalysisID of 70Se
This is the latest ID of 70Se setting.
  157   Wed Jun 30 19:08:25 2021 Rui-Jiu ChenAnalysisID of 70Se spectrum recorded in May
  162   Wed Jun 30 23:29:42 2021 Rui-Jiu ChenAnalysisStart a new run.
reference level=-20 dBm.
p:\E143\sc\SC_2021-6-30_23_27_45
p:\E143\iq\IQ_2021-6-30_23_27_34
  168   Thu Jul 1 15:25:42 2021 Rui-Jiu ChenDAQtemplate of NTCAP shift
Please check following two parameters every two hours into make sure the NTCAP is running well: 
1. The latest recorded tdms files:
 p:\E143\sc\**\**
 p:\E143\iq\**\**
2. The rest space on the drive "p:\" : **GByte.
  107   Sun May 9 16:19:06 2021 Rodostina, Oliver, Wolfram, ShahabRunsSetting to 52Mn ????
first filename in this recording:

E143-245MHz-2021.05.09.15.16.49.816.tiq
  109   Sun May 9 18:41:33 2021 Rodostina, Oliver, Wolfram, Helmut, Yuri, ShahabRunsstopped data taking for energy change
last recorded filename:

E143-245MHz-2021.05.09.17.38.44.410.tiq

410 was not recording data in this period.
  111   Sun May 9 19:03:02 2021 Rodostina, Oliver, Wolfram, Helmut, Yuri, ShahabRunsquadrupoles were down, fixed.
  17   Thu May 6 21:36:04 2021 Regina + Markus + YuriAcceleratorCooler Curve
Final cooler curve, Isochronous 78Kr
ELOG V3.1.5-fc6679b