ID |
Date |
Author |
Category |
Subject |
Text |
|
98
|
Sun May 9 06:15:09 2021 |
Iris, Chris G., Jacobus, Michele | Runs | Triplet: zoom in | Zoom into the triplet: the satellite peaks
on the right are clearly visible.
This is just one file but one *might* see |
|
99
|
Sun May 9 06:34:37 2021 |
Iris, Chris G., Jacobus, Michele | Analysis | Runs 2-3am Not_Mn52 | Summed up runs on the 245 MHz detector between
2-3am (computer time).
One has -s 0.1 -t 8.0
|
|
100
|
Sun May 9 06:53:20 2021 |
Iris, Chris G., Jacobus, Michele | General | Summary night shift | The tune last night was unfortunately not
to 52Mn. The two "isomers" that were identified
are instead 45Sc and 75Br. But separation |
|
101
|
Sun May 9 07:16:47 2021 |
Iris, Chris G., Jacobus, Michele | Analysis | Runs 3-4am Not_Mn52 | Summed up runs on the 245 MHz detector between
3-4am (computer time).
-s 0.1 -t 8.0 |
|
171
|
Thu Jul 1 17:01:43 2021 |
Jacobus | Runs | Frequency shift | > The freqency suddenly shifted at time 16:11:47
and remained shifted until now
>
|
|
89
|
Sun May 9 02:45:50 2021 |
Jacobus, Michele, Shahab | Runs | Example of possible 52.Mn isomer | this is how it should look like |
|
87
|
Sun May 9 02:19:04 2021 |
Jacobus, Shahab | Runs | First 52Mn run | Run E143-245 MHz-2021.05.09.01.17.42.265.tiq
is the first run of the experiment on 52Mn. |
|
88
|
Sun May 9 02:32:58 2021 |
Jacobus, Shahab | Runs | possible 52-Mn isomer | the intensity of the line on the left side
is so high, it is difficult to see the isomers
in the middle as can be seen in the auto |
|
1
|
Fri Apr 23 13:47:55 2021 |
Jan Glorius | Collaboration | experiment proposal | |
|
166
|
Thu Jul 1 07:28:55 2021 |
Jan, Akash | Accelerator | Beam intensity | Intensity went up from 5e8 to 1e9 extracted
particles from SIS. |
|
123
|
Mon May 10 00:51:38 2021 |
Kanika, Alex, RuiJiu | General | No beam in SIS | The beam was lost in SIS about 5 mins ago
due to the failure of HF cavities. Operators
are trying to solve the problem. |
|
124
|
Mon May 10 01:01:59 2021 |
Kanika, Alex, RuiJiu | General | Beam is back | The issue has been resolved and the beam is
back since 00:56. |
|
133
|
Mon May 10 08:49:01 2021 |
Kanika, Alex, RuiJiu | General | End of the measurement | The beam was stopped at about 08:40. |
|
129
|
Mon May 10 06:16:31 2021 |
Kanika, Alex, Shahab | Runs | Recording broad band spectra with 410 | doing some broadband spectra recording with
the 410 MHz detector, for the purpose of
future confirmation of identification lines. |
|
131
|
Mon May 10 06:35:58 2021 |
Kanika, Alex, Shahab | Runs | going back to shot by shot recording with 410 detector | going back to shot by shot recording with
410 detector |
|
117
|
Sun May 9 23:28:25 2021 |
Kanika, Alex, Wolfram, Helmut, Shahab | Runs | return with the Ge setting of the last night | starting filenames:
E143-410MHz-2021.05.09.23.28.24.018.tiq
|
|
55
|
Fri May 7 18:43:13 2021 |
Kanika, Michael, Shahab | Runs | cave M experiment needs more spills | our pattern causes beam loss while scanning
the biological probes in the Cave M bio experiment.
They loose every other spill due to high |
|
56
|
Fri May 7 19:56:10 2021 |
Kanika, Michael, Shahab | Runs | ZOOM session restart | restart zoom session |
|
57
|
Fri May 7 20:28:32 2021 |
Kanika, Michael, Shahab | Analysis | Some pictures from the 410 detector | some pics. |
9x |
58
|
Fri May 7 20:34:27 2021 |
Kanika, Michael, Shahab | Runs | back to 15 sec recording | now we are going back to 15 sec operation.
Cave M (bio) operation is over |
|