| ID | Date | Author | Category  | Subject | 
| 18 | Thu May  6 21:45:30 2021 | Helmut | Detectors | beam position on TE5 grids | 
| The two grids do not work very well, one x position is opposite to the other.
But at least a guidance for the future, this was good injection of 78Kr with a thick Be target. | 
| Attachment 1: 2021-05-06_21-32-36-171.png | 
|   | 
| 12 | Thu May  6 16:45:42 2021 | Ragan, Rui-Jiu | DAQ | Data taking with NTCAP | 
| NTCAP is on and data taking has started.
On time: 16:39
SC_2021-05-06_16-39-09
\IQ_2021-05-06_16-39-09
IQ Rate: 20 MS/s
Carrier frequency: 245 MHz
Reference level(dBm):-30
RF attenuation(dB):40
IF attenuation(dB):19.9288
Data file
Samples/records:2^18=262144
Records/File:2^12=4096
SC file: 
Entries/file:2^18=262144
Master path:
o:\E143\iq 
o:\E143\sc | 
| Attachment 1: 1.jpg | 
|   | 
| Attachment 2: 2.jpg | 
|   | 
| 13 | Thu May  6 17:02:49 2021 | Ragan, Rui-Jiu | DAQ | Scaler signals and parameters of NTCAP | 
| At the moment, we record 7 signals in scaler channels and one Schottky signal (245 MHz resonance cavity) in the NTCAP with the attached information. | 
| Attachment 1: p1.JPG | 
|   | 
| Attachment 2: p2.JPG | 
|   | 
| Attachment 3: p4.png | 
|   | 
| 15 | Thu May  6 18:21:42 2021 | Ragan, Rui-Jiu | DAQ | NTCAP started again | 
| NTCAP was stopped at 17:34 for the optimisation purpose.
NTCAP started again at 18:20 with the change in Reference Level (dBm): 0
SC_2021-05-06_18-20-05
\IQ_2021-05-06_18-20-05 | 
| Attachment 1: IMG_20210506_182118.jpg | 
|   | 
| Attachment 2: IMG_20210506_182017.jpg | 
|   | 
| 20 | Thu May  6 23:06:18 2021 | Rui-Jiu Chen | DAQ | Change reference level to -50dBm | 
| Beam is secondary beam now. The intensity is lower. Change reference level to -50dBm.
Carrier frequency:245MHz
IQ rate(S/s): 20M.
Reference Level: -50 dBm.
Start taking data.
SC_2021-05-06_23_02_46
IQ_2021-05-06_23_02_33 | 
| 22 | Fri May  7 01:44:24 2021 | Rui-Jiu Chen | DAQ | Change reference level to -40dBm | 
| Reference Level: -40 dBm.
Start taking data.
SC_2021-05-07_00-06-57
IQ_2021-05-07_00-06-57 | 
| 23 | Fri May  7 01:47:36 2021 | Ragan, Rui-Jiu | DAQ | Change reference level to -30dBm | 
| Reference Level: -30 dBm.
Start taking data.
SC_2021-05-07_00-11-24
IQ_2021-05-07_00-11-24 | 
| 24 | Fri May  7 01:49:03 2021 | Rui-Jiu Chen | DAQ | Comparison of I_Raw/Q_Raw between different reference level | 
| This is a comparison of I_Raw/Q_Raw between different reference level. The range of NTCAP ADC is only 2^15 bit. So signals (I_Raw and Q_Raw) should 
not be outside ADC range. It is clear that there is not point outside the ADC range when using reference level -30dBm. | 
| Attachment 1: 20210501_NTCAPPreparation.png | 
|   | 
| 66 | Sat May  8 03:05:42 2021 | Rui-Jiu Chen | DAQ | Change reference level to -60dBm | 
| Start a new run. The data of new run is in :
SC_2021-05-07_17-33-29
IQ_2021-05-07_17-33-29 | 
| 67 | Sat May  8 03:08:57 2021 | Rui-Jiu Chen | DAQ | Change reference level to -50dBm | 
| Start a new run. The data of new run is in :
SC_2021-05-07_17-39-16
IQ_2021-05-07_17-39-16 | 
| 78 | Sat May  8 18:35:25 2021 | Rui-Jiu Chen | DAQ | Change reference level to -10dBm | 
| The beam in ESR is 78Kr36+@476 MeV/u.
Start a new run:
SC_2021-05-08_18-25-52
IQ_2021-05-08_18-25-52 | 
| 79 | Sat May  8 19:51:46 2021 | Ragan, Rui-Jiu | DAQ | Change reference level to -50dBm | 
| Start a new run. The data of new run is in :
SC_2021-05-08_19-51-35
IQ_2021-05-08_19-51-35 | 
| 119 | Sun May  9 23:59:26 2021 | Rui-Jiu Chen | DAQ | Start a new run. | 
| Start a new run. The data of new run is in :
reference level = -50dBm.
SC_2021-05-09_23-43-37
IQ_2021-05-09_23-43-37 | 
| 120 | Mon May 10 00:00:49 2021 | Ragan, Rui-Jiu | DAQ | Change reference level to -70dBm | 
| Start a new run. The data of new run is in :
SC_2021-05-09_23-56-42
IQ_2021-05-09_23-56-42 | 
| 121 | Mon May 10 00:08:26 2021 | Rui-Jiu Chen | DAQ | Change reference level to -60dBm | 
| Start a new run. The data of new run is in :
SC_2021-05-10_00-08-08
IQ_2021-05-10_00-08-08 | 
| 136 | Mon Jun 28 18:32:49 2021 | Ruijiu, Shahab | DAQ | trigger signal connected to NTCAP and analyzers | 
|  | 
| Attachment 1: tri.jpg | 
|   | 
| 139 | Tue Jun 29 20:40:55 2021 | Rui-Jiu Chen | DAQ | start NTCAP | 
| Carrier Frequency:245MHz.
IQ rate 20MSamples/s
Reference level:-90 dBm
SC_2021-06-29_20-38-27
IQ_2021-06-29_20-38-27 | 
| 168 | Thu Jul  1 15:25:42 2021 | Rui-Jiu Chen | DAQ | template of NTCAP shift | 
| Please check following two parameters every two hours into make sure the NTCAP is running well: 
1. The latest recorded tdms files:
 p:\E143\sc\**\**
 p:\E143\iq\**\**
2. The rest space on the drive "p:\" : **GByte. | 
| 172 | Thu Jul  1 18:01:52 2021 | Andrew Nic Shahab | DAQ | Change triggers to 10% | 
| Change the triggers to 10%. Last files with 50/50:
410MhZ 2021-.07.01.17.56.12.936
245MhZ 2021.07.01.18.02.16.938  | 
| 178 | Thu Jul  1 19:34:11 2021 | Shahab | DAQ | increase factor 4 in power for 410 | 
| increase factor 4 in power for 410 
before:
410MHz-2021.07.01.18.48.07.516.tiq.png
after:
410MHz-2021.07.01.19.23.49.099.tiq.png | 
| Attachment 1: 410MHz-2021.07.01.19.23.49.099.tiq.png | 
|   | 
| Attachment 2: 410MHz-2021.07.01.18.48.07.516.tiq.png | 
|   |