| ID | 
Date | 
Author | 
Category | 
Subject  | 
Text | 
  | 
| 
  169  
 | 
Thu Jul  1 16:27:57 2021 | 
Andrew Nic | General | NTCAP parameters | The latest recorded tdms files:
 
 p:\E143\sc\SC_2021-06-30_23-27-45\0000233
 
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001138
 | 
   | 
| 
  181  
 | 
Thu Jul  1 21:15:01 2021 | 
Andrew Nic | DAQ | NTCAP Status | The latest recorded tdms files:
 
 p:\E143\sc\SC_2021-06-30_23-27-45\0000299
 
 p:\E143\iq\IQ_2021-06-30_23-27-34\0001462
 | 
   | 
| 
  141  
 | 
Tue Jun 29 21:12:15 2021 | 
Kanika, Shahab | Runs | Moving the resonance frequency of the 245 MHz resonator  | moving in the plungers:
 
 
before: 400
 | 
    | 
| 
  68  
 | 
Sat May  8 07:14:00 2021 | 
Akash, Nic, Jelena, Zsolt | General | Morning shift entry | Things look ok. No settings have been changed...
 
 
Analysis attempts are going on... | 
   | 
| 
  163  
 | 
Thu Jul  1 00:09:28 2021 | 
David, Liliana | General | Low beam intensity  for few minutes | For few minutes (starting at 00:05) beam intensity 
went down. Same as it was reported by the 
previous shift. 
 | 
   | 
| 
  Draft  
 | 
Sat Jul  3 06:49:55 2021 | 
The remote Canadian eager beavers (Guy &Iris) | Analysis | List of possible spectra with isomer decay | Attached is an example for the possible isomer 
(on the left) next to the 70Se (right). 
 
 | 
    | 
| 
  186  
 | 
Thu Jul  1 23:46:17 2021 | 
Iris | General | Less beam after gas bottle change? | Looks like there is a bit less beam now in 
the ring. I just looked at one spectra from 
before the gas bottle change and after... | 
    | 
| 
  187  
 | 
Thu Jul  1 23:54:43 2021 | 
Iris | General | Less beam after gas bottle change? | No, everything okay! Must have had a very 
good earlier run to compare.
 
 | 
    | 
| 
  134  
 | 
Thu Jun 24 22:05:11 2021 | 
Helmut Weick | Accelerator | LISE files for 72Ge, 70Se, 52Mn settings | This is just a Brho selection by the ESR based 
on SIS-energy used, 
 
energy-loss in target with calibrated thickness | 
      | 
| 
  2  
 | 
Wed Apr 28 09:36:39 2021 | 
Helmut Weick | Simulations | LISE file for fragments from TE3UF into ESR | Uncooled beam on target at TE3UF with dispersion 
and slit in TE beamlne and realistic injection 
into ESR.
 | 
     | 
| 
  74  
 | 
Sat May  8 11:42:21 2021 | 
Yuri | Accelerator | KPs | EO1KP03 was on = -44.9 A
 
E01KP05 was off, now is on = 3.67 A
 
The beam is on the right frequency, but the | 
   | 
| 
  164  
 | 
Thu Jul  1 01:35:15 2021 | 
David, Liliana | General | Ion source change | Changing ion source, no beam expected for 
the next 30 minutes.
 
 | 
   | 
| 
  40  
 | 
Fri May  7 09:56:43 2021 | 
Yuri | Calibration | Identification Verification | With closed scrapers there are only a few 
weak lines.
 
Open temporarily all scrapers in the ESR | 
   | 
| 
  135  
 | 
Fri Jun 25 21:47:24 2021 | 
Yuri | Analysis | Identification | Attached are two files with a proposed particle 
identification.
 
Different colors indicate different harmonic | 
     | 
| 
  157  
 | 
Wed Jun 30 19:08:25 2021 | 
Rui-Jiu Chen | Analysis | ID of 70Se spectrum recorded in May |   | 
       | 
| 
  144  
 | 
Wed Jun 30 00:20:10 2021 | 
Rui-Jiu Chen | Analysis | ID of 70Se setting on May | This is an old spectrum which was recoded 
on May. | 
       | 
| 
  152  
 | 
Wed Jun 30 13:05:08 2021 | 
Rui-Jiu Chen | Analysis | ID of 70Se | This is the latest ID of 70Se setting. | 
        | 
| 
  8  
 | 
Thu May  6 00:32:57 2021 | 
Helmut Weick | Simulations | GICOSY file for TE beamline and ESR | This file has several options:
 
start in SIS, at TE3UF target or inside ESR, 
choose with GOTO LABEL (G L)after start system | 
     | 
| 
  43  
 | 
Fri May  7 10:46:40 2021 | 
Yuri | Accelerator | GE02DS3HG | The scraper is blocked at -10 mm and -unfortunately- 
blocks the beam in the ESR. Uli Popp is taking 
care. | 
   | 
| 
  170  
 | 
Thu Jul  1 16:47:15 2021 | 
Andrew Nic | Runs | Frequency shift | The freqency suddenly shifted at time 16:11:47 
and remained shifted until now 
 
 | 
   |