85
|
Tue May 31 07:29:11 2022 |
Ken | Detectors | XUV-Detektor |
Rate was very low: ~ 100Hz
Adjusted Walk level and Threshold, new rate: 5kHz
Additionally, parameters of the detector were varied for optimization but were returned to default afterwards. |
84
|
Mon May 17 21:43:56 2021 |
Danyal | General | The test beamtime was a success. |
Dear all,
The test beamtime is now over.
We had 6 days of Li-like carbon in the ESR (122 MeV/u).
Effectively, we could measure almost 5 days continuously.
There were only a few interruptions, one of which was a longer power failure.
The vacuum in the ESR was not optimal, which strongly reduced the lifetime of the stored ion beam (~30 s)
and the electron cooler showed weird instabilities, which need to be clarified still.
Still, we were able to cover all aspects of the program.
Essentially everything we tried worked.
Therefore, I conclude that it was a great success.
Many thanks to all who have contributed to it!
Special thanks to Sebastian and Benedikt - who worked really hard during the last months - for prepapring the laser system and the data acquisition system.
Also special thanks to Volker and Ken for preparing the XUV detector system.
We will start sorting/ordering & filtering the data soon and will invite for a meeting where we present the raw data so that we can discuss it.
Then we will also discuss the next big step: data analysis.
Of course it is our next objective (with high priority) to publish the analyzed data in foreseeable time.
I hope to see you soon.
Until then, take care and stay healthy,
Danyal |
83
|
Mon May 17 08:05:42 2021 |
Team | General | End of beamtime |
~ 8 a.m. |
82
|
Sun May 16 22:11:49 2021 |
Team | General | Laser Polarisation values |
maximal transmission of PBSC (257/514 pbsc was used in combination with xlp12 detector and visual on a screen):
L/4 @ 276° & L/2 @ 348° --> p-polarized light
L/4 gleich auf 276° & L/2 auf ~19° --> s-polarized light
current position 22:15 p.m.
now we have some fun ! :D |
81
|
Sun May 16 21:23:02 2021 |
Team | General | ESR OPEN -> preparation for Polarisation Tests |
|
80
|
Sun May 16 11:29:22 2021 |
Benedikt | General | Automated laser scans working |
The automated laser scans are working now.
We can now scan with the following functions: triangle, sawtooth, cosinus/sinus, arctan, min (linear scan, than stands still)
We are now testing these scan functions with coasting beams; ecooler 10 mA. |
79
|
Sun May 16 07:18:56 2021 |
Night Shift Sebastian/Max/Noah | General | Preparation for automated laser scans |
We shut the laser system down to prepare automated laser scans |
78
|
Sun May 16 07:03:07 2021 |
Team | General | Laser cooling with 166ps |
We saw some indications of laser cooling @ 166ps pulse length |
77
|
Sun May 16 06:13:46 2021 |
Team | General | Switch to 166ps |
|
76
|
Sun May 16 05:24:00 2021 |
Team | General | Laser cooling with 285ps |
we also see laser cooling with 285ps pulse length |
75
|
Sun May 16 05:09:27 2021 |
Team | General | Switch to 285ps |
pulse length -> 285ps
minimum 62mW inside ESR (depending on laser wavelength) |
74
|
Sun May 16 05:09:04 2021 |
Team | General | Laser cooling with 482ps |
we see laser cooling with 482ps pulse length |
73
|
Sun May 16 02:28:21 2021 |
Team | General | #Beam ON! |
Laser specs:
pulse length -> 482ps
~75mW UV Power inside ESR (depending on laser wavelength) |
72
|
Sun May 16 02:22:19 2021 |
Sebastian | General | "Der Laser ist ok" |
|
Draft
|
Sun May 16 02:20:58 2021 |
Sebastian | General | "Der Laser ist (wieder) ok" |
|
70
|
Sun May 16 02:18:53 2021 |
Sebastian | General | UV Drop |
1:25 a.m. huge drop in UV laser power
-> small crystal bump with both y screws of bbo oven |
69
|
Sat May 15 12:11:54 2021 |
Benedikt | General | Laser-bunch-timing |
Optimizing the laser bunch timing.
h = 7 (9.0389145 MHz)
Reprate is already set to same frequency.
Results: For h=7:
4 ns delay results in a maximum fluorescence rate in the XUV detector
25 ns delay shows the highest intensity in the Schottky spectrum while the laser operates at 1028.940 nm. |
68
|
Sat May 15 11:26:44 2021 |
Benedikt | General | TEM parameters |
We changed the horizontal position of the laser beam a bit, so that we maximized the fluorescence signal on the XUV detector (coasting beam, scanning laser (0.03 Hz)).
Old parameters: OffsetM Ax 0.00; Bx 0.00; Ay -0.08; By -0.40
New parameters: OffsetM Ax 0.00; Bx 0.35; Ay -0.08; By -0.40 |
67
|
Sat May 15 11:06:31 2021 |
Benedikt | General | New Zoom link for the moment |
https://tu-darmstadt.zoom.us/j/4948400422?pwd=SEJaUzBuYXM0TTd6UWxoZTFlWEZxUT09
Meeting ID: 494 840 0422
Passcode: 215586 |
66
|
Sat May 15 09:57:24 2021 |
Dayshift | Runs | Currently on schedule |
Enhance fluorescence rate and perform
laser bunch timing
Right now: Performing several detector tests with scanning laser (triangle) between 1028.930 and 1028.950 nm. Eccoler current @ 10 mA |