Tue May 31 07:29:11 2022, Ken, Detectors, XUV-Detektor
|
Rate was very low: ~ 100Hz
Adjusted Walk level and Threshold, new rate: 5kHz
Additionally, parameters of the detector were varied for optimization but were returned to default afterwards. |
Mon May 17 21:43:56 2021, Danyal, General, The test beamtime was a success.
|
Dear all,
The test beamtime is now over.
We had 6 days of Li-like carbon in the ESR (122 MeV/u).
Effectively, we could measure almost 5 days continuously.
There were only a few interruptions, one of which was a longer power failure.
The vacuum in the ESR was not optimal, which strongly reduced the lifetime of the stored ion beam (~30 s)
and the electron cooler showed weird instabilities, which need to be clarified still.
Still, we were able to cover all aspects of the program.
Essentially everything we tried worked.
Therefore, I conclude that it was a great success.
Many thanks to all who have contributed to it!
Special thanks to Sebastian and Benedikt - who worked really hard during the last months - for prepapring the laser system and the data acquisition system.
Also special thanks to Volker and Ken for preparing the XUV detector system.
We will start sorting/ordering & filtering the data soon and will invite for a meeting where we present the raw data so that we can discuss it.
Then we will also discuss the next big step: data analysis.
Of course it is our next objective (with high priority) to publish the analyzed data in foreseeable time.
I hope to see you soon.
Until then, take care and stay healthy,
Danyal |
Mon May 17 08:05:42 2021, Team, General, End of beamtime
|
~ 8 a.m. |
Sun May 16 22:11:49 2021, Team, General, Laser Polarisation values
|
maximal transmission of PBSC (257/514 pbsc was used in combination with xlp12 detector and visual on a screen):
L/4 @ 276° & L/2 @ 348° --> p-polarized light
L/4 gleich auf 276° & L/2 auf ~19° --> s-polarized light
current position 22:15 p.m.
now we have some fun ! :D |
Sun May 16 21:23:02 2021, Team, General, ESR OPEN -> preparation for Polarisation Tests
|
|
Sun May 16 11:29:22 2021, Benedikt, General, Automated laser scans working
|
The automated laser scans are working now.
We can now scan with the following functions: triangle, sawtooth, cosinus/sinus, arctan, min (linear scan, than stands still)
We are now testing these scan functions with coasting beams; ecooler 10 mA. |
Sun May 16 07:18:56 2021, Night Shift Sebastian/Max/Noah, General, Preparation for automated laser scans
|
We shut the laser system down to prepare automated laser scans |
Sun May 16 07:03:07 2021, Team, General, Laser cooling with 166ps
|
We saw some indications of laser cooling @ 166ps pulse length |
Sun May 16 06:13:46 2021, Team, General, Switch to 166ps
|
|
Sun May 16 05:24:00 2021, Team, General, Laser cooling with 285ps
|
we also see laser cooling with 285ps pulse length |
Sun May 16 05:09:27 2021, Team, General, Switch to 285ps
|
pulse length -> 285ps
minimum 62mW inside ESR (depending on laser wavelength) |
Sun May 16 05:09:04 2021, Team, General, Laser cooling with 482ps
|
we see laser cooling with 482ps pulse length |
Sun May 16 02:28:21 2021, Team, General, #Beam ON!
|
Laser specs:
pulse length -> 482ps
~75mW UV Power inside ESR (depending on laser wavelength) |
Sun May 16 02:22:19 2021, Sebastian, General, "Der Laser ist ok"
|
|
Sun May 16 02:20:58 2021, Sebastian, General, "Der Laser ist (wieder) ok"
|
|
Sun May 16 02:18:53 2021, Sebastian, General, UV Drop
|
1:25 a.m. huge drop in UV laser power
-> small crystal bump with both y screws of bbo oven |
Sat May 15 12:11:54 2021, Benedikt, General, Laser-bunch-timing
|
Optimizing the laser bunch timing.
h = 7 (9.0389145 MHz)
Reprate is already set to same frequency.
Results: For h=7:
4 ns delay results in a maximum fluorescence rate in the XUV detector
25 ns delay shows the highest intensity in the Schottky spectrum while the laser operates at 1028.940 nm. |
Sat May 15 11:26:44 2021, Benedikt, General, TEM parameters
|
We changed the horizontal position of the laser beam a bit, so that we maximized the fluorescence signal on the XUV detector (coasting beam, scanning laser (0.03 Hz)).
Old parameters: OffsetM Ax 0.00; Bx 0.00; Ay -0.08; By -0.40
New parameters: OffsetM Ax 0.00; Bx 0.35; Ay -0.08; By -0.40 |
Sat May 15 11:06:31 2021, Benedikt, General, New Zoom link for the moment
|
https://tu-darmstadt.zoom.us/j/4948400422?pwd=SEJaUzBuYXM0TTd6UWxoZTFlWEZxUT09
Meeting ID: 494 840 0422
Passcode: 215586 |
Sat May 15 09:57:24 2021, Dayshift, Runs, Currently on schedule
|
Enhance fluorescence rate and perform
laser bunch timing
Right now: Performing several detector tests with scanning laser (triangle) between 1028.930 and 1028.950 nm. Eccoler current @ 10 mA |