ID Dateup Author Category Subject
  1   Mon May 10 07:58:13 2021 DanyalGeneralTelephone numbers and Zoom link
Telephone numbers:

ESR laser lab: +49 (0)6159 71 - 2882
ESR measurement hut: +49 (0)6159 71 - 2880
HKR (main control room): +49 (0)6159 71 - 2317 or 2245

here is the zoom information:

https://tu-darmstadt.zoom.us/j/2183997317?pwd=WGc2TEkxYlEyNFhMWm02bFhqRnRVUT09

Meeting-ID: 218 399 7317
Passwort: 481607
  2   Tue May 11 15:49:30 2021 DanyalGeneralsetting up ESR
The operators are still busy extracting the beam from the SIS18 towards the ESR and injecting it into the ESR. 
  3   Tue May 11 16:07:59 2021 SebastianDAQDAQ Manual
Attached you'll find a short manual for operating the whole DAQ system
Attachment 1: DAQ_Manual.pdf
DAQ_Manual.pdf DAQ_Manual.pdf DAQ_Manual.pdf
  4   Tue May 11 16:33:31 2021 Ken UeberholzDetectorsDetector control manual
Attached to this elog entry is a short manual for the xuv-detector control. If anything is missing or not understandable I can change anything.
Attachment 1: Manual.pdf
Manual.pdf Manual.pdf Manual.pdf Manual.pdf
  5   Tue May 11 18:29:35 2021 DanyalGeneralfirst ions in the ESR
Attachment 1: first_ions_are_injected.jpg
first_ions_are_injected.jpg
  6   Tue May 11 20:14:43 2021 DanyalGeneralbad ESR vacuum
I just heard that the ESR vacuum is quite bad. 
There was a small vacuum problem a while ago, it was sealed, but apparently the pressure is not as low as usual.

Markus Steck said that the beam lifetime is only 15 - 20 seconds !!! 

This will seriously complicate some of our test experiments :( 
  Draft   Wed May 12 02:16:25 2021 Danyal, LarsAcceleratorIon beam position
Laser Position with scrapers verified. 
1HA: impossible to scratch laser beam, still there at -1.0 mm
2HA: +3mm --> half the laser power on detector; +4.5mm --> gone

2VO: interlock, impossible to move (beam diagnostics is informed and will check)
1VO: +0.2mm --> half laser power, +1.2: laser gone (-1.0mm: also gone)

Ion beam adapted to measured laser beam, Target bump position: -22mm (was -18mm before)
Ion beam position verified with scrapers:
1HA: -1.0mm --> still there
2HA: +4.0mm --> beam gone
Target bump angle: unchanged (+1.2 mrad)
  8   Wed May 12 02:34:29 2021 DanyalGeneralinstabilities in ion frequency
The ion beam moves around, pretty arbitrary. See picture. 
ESR crew believes that it is not due to fluctuations in the HV of the E-Cooler. 
Attachment 1: fluctuations.jpg
fluctuations.jpg
  10   Wed May 12 08:10:17 2021 LarsGeneralinstabilities in ion frequency
looks like the E-Cooler is responsible for this. If one turns off the electron current, the beam stays stable. 
M.Steck is informed.

> The ion beam moves around, pretty arbitrary. See picture. 
> ESR crew believes that it is not due to fluctuations in the HV of the E-Cooler. 
  11   Wed May 12 08:32:04 2021 SebastianAnalysisfluorescence & energetic overlap
During the night shift we saw several rises of the fluorescence (see another entry) and also energetic overlap in coasting beam modus.
Here the laser wavelength was stabilized @ 1028,967nm and electron cooler was switched off because of some fluctuations which we saw in the schottky.
Left part of the schottky picture shows the c3+ beam, the right part is the o4+ contamination.
Attachment 1: Screenshot_(154).png
Screenshot_(154).png
  12   Wed May 12 08:41:36 2021 SebastianAnalysisLaser stability
During night shift the laser was very stable! Only minor fluctuations occured in the UV
  13   Wed May 12 08:42:49 2021 SebastianAnalysisLaser scans / coastig beam / no ecooler
Attached you'll see a first laser scan of ~100GHz in the UV.
Attachment 1: Screenshot_(156).png
Screenshot_(156).png
  14   Wed May 12 09:04:48 2021 SebastianDAQKeysight AUtoCal
Attachment 1: IMG_20210510_143940_resized_20210512_090353546.jpg
IMG_20210510_143940_resized_20210512_090353546.jpg
  Draft   Wed May 12 09:05:48 2021 Keysight SettingsDAQ 
  16   Wed May 12 09:09:15 2021 SebastianDAQFluorescence
fluorescence with detector in parking position
fixed laser wavelength
electron cooling ON, 
BUT we saw strange drifts in the Schottky spectra. It seems to be that these drifts come from the electron cooler! are the drift tubes grounded?

the drifts shift the ion beam over the transition which result in an increase of the XUV anode signal
Attachment 1: 1029967nm.png
1029967nm.png
  17   Wed May 12 09:59:08 2021 BenediktGeneralRigol DSG821 signal generator settings
Attachment 1: CF7701F6-86BE-406C-8FAD-F3161463181C.jpeg
CF7701F6-86BE-406C-8FAD-F3161463181C.jpeg
  18   Wed May 12 10:14:18 2021 LarsAcceleratorE-Cooler
M.Steck et al. discussed about the E-Cooler and found a possible issue. They asked for enterance to the ESR. Since nobody else was in the HKR and anyway nothing was running because of some other issues, I told, the experiment would not be disturbed and they could enter and do things. (Sth. like putting some repeller electrodes onto hand and other magical things).
It should take about 10 Minutes and might be already finished by now.
  19   Wed May 12 10:15:47 2021 Volker HannenDAQUnplugged TDC inputs for MCP front and back
To reduce the load on the VUPROM TDC, we unplugged the TDC inputs for the front and back signals of the MCP of the XUV detector.
The Anode signal is still plugged in and should be sufficient for the analysis.
  20   Wed May 12 13:11:58 2021 DanyalAcceleratorshort break between 13:30 and 15:30
There will be a short break (2 hours) this afternoon. Between 13:30 and 15:30. 
The so-calles "super lense" in the UNILAC needs to be cleaned (rinsed). 
After that operation should continue as usual. 
  21   Wed May 12 15:36:04 2021 DanyalAcceleratorgeneral power failure in ESR! (everything is off)
The power in the ESR is off. 
(also on the gas-target area on top of ESR)
Electrical engineers are trying to find and fix the problem. 