Sat May 15 06:51:16 2021 |
Night Shift Sebastian/Max/Noah | General | Different Laserscantypes |
We use different scan types (manual scan) or constant laser wavelengths to check the effects of laser cooling in the Schottky diagrams (fluorescence can not be seen in the detector), for different bunching amplitudes and frequencies:
- Scan from 1028.950 -> 1028.940, stepsize 0.001 every 10 sec
- Scan from 1028.950 -> 1028.930, stepsize 0.001 every 5 sec
- Scan from 1028.950 -> 1028.940 -> 1029.950, stepsize 0.001 every 5 sec
- Scan from 1028.950 -> 1028.940, stepsize 0.0005 "as fast as possible"
- constant wavelengths around 1028.940
- Scan to wavelengths < 1028.940 (heating) -> Jump to 1028.945 and fast scan back to 1028.940 (-> cooling)
The cooling effects of the laser can be observed well in the Schottky spectra :) |
63
|
Sat May 15 09:22:41 2021 |
Sebastian | Accelerator | Ekühler |
Settings für Ekühler an und aus in SC4 und
5 |
64
|
Sat May 15 09:23:52 2021 |
Sebastian | Accelerator | Ekühler |
Tab "Kühler Elektronenstrahl"
An Gerät schicken |
65
|
Sat May 15 09:50:31 2021 |
Team | Runs | Laser cooling of.... |
H=2
H=7
H=10
H=20
H=30
We performed several scans:
Close to the bucket middle
Over the bucket
Over the bucket, jumped to the "red side"
of the bucket and captured and cooled the
beam again.
Laser settings:
7 times revolution frequency and 740ps
pulses - - > 3.4 +/- 1.2 GHz
Still to do:
Switch to 240ps pulses - - > 5.8GHz
+/-1.3 GHz
Maybe:
Switch to 117ps pulses - - > 11.0 +/- 0.8 GHz
BUT here we have less laser power (max. 50 mW right after BBO crystal, so maybe only 30 mW at the laser-ion overlap)
available. Maybe we are lucky and it is
enough to cool also the ion beam. :) |
66
|
Sat May 15 09:57:24 2021 |
Dayshift | Runs | Currently on schedule |
Enhance fluorescence rate and perform
laser bunch timing
Right now: Performing several detector tests with scanning laser (triangle) between 1028.930 and 1028.950 nm. Eccoler current @ 10 mA |
67
|
Sat May 15 11:06:31 2021 |
Benedikt | General | New Zoom link for the moment |
https://tu-darmstadt.zoom.us/j/4948400422?pwd=SEJaUzBuYXM0TTd6UWxoZTFlWEZxUT09
Meeting ID: 494 840 0422
Passcode: 215586 |
68
|
Sat May 15 11:26:44 2021 |
Benedikt | General | TEM parameters |
We changed the horizontal position of the laser beam a bit, so that we maximized the fluorescence signal on the XUV detector (coasting beam, scanning laser (0.03 Hz)).
Old parameters: OffsetM Ax 0.00; Bx 0.00; Ay -0.08; By -0.40
New parameters: OffsetM Ax 0.00; Bx 0.35; Ay -0.08; By -0.40 |
69
|
Sat May 15 12:11:54 2021 |
Benedikt | General | Laser-bunch-timing |
Optimizing the laser bunch timing.
h = 7 (9.0389145 MHz)
Reprate is already set to same frequency.
Results: For h=7:
4 ns delay results in a maximum fluorescence rate in the XUV detector
25 ns delay shows the highest intensity in the Schottky spectrum while the laser operates at 1028.940 nm. |
70
|
Sun May 16 02:18:53 2021 |
Sebastian | General | UV Drop |
1:25 a.m. huge drop in UV laser power
-> small crystal bump with both y screws of bbo oven |
Draft
|
Sun May 16 02:20:58 2021 |
Sebastian | General | "Der Laser ist (wieder) ok" |
|
72
|
Sun May 16 02:22:19 2021 |
Sebastian | General | "Der Laser ist ok" |
|
73
|
Sun May 16 02:28:21 2021 |
Team | General | #Beam ON! |
Laser specs:
pulse length -> 482ps
~75mW UV Power inside ESR (depending on laser wavelength) |
74
|
Sun May 16 05:09:04 2021 |
Team | General | Laser cooling with 482ps |
we see laser cooling with 482ps pulse length |
75
|
Sun May 16 05:09:27 2021 |
Team | General | Switch to 285ps |
pulse length -> 285ps
minimum 62mW inside ESR (depending on laser wavelength) |
76
|
Sun May 16 05:24:00 2021 |
Team | General | Laser cooling with 285ps |
we also see laser cooling with 285ps pulse length |
77
|
Sun May 16 06:13:46 2021 |
Team | General | Switch to 166ps |
|
78
|
Sun May 16 07:03:07 2021 |
Team | General | Laser cooling with 166ps |
We saw some indications of laser cooling @ 166ps pulse length |
79
|
Sun May 16 07:18:56 2021 |
Night Shift Sebastian/Max/Noah | General | Preparation for automated laser scans |
We shut the laser system down to prepare automated laser scans |
80
|
Sun May 16 11:29:22 2021 |
Benedikt | General | Automated laser scans working |
The automated laser scans are working now.
We can now scan with the following functions: triangle, sawtooth, cosinus/sinus, arctan, min (linear scan, than stands still)
We are now testing these scan functions with coasting beams; ecooler 10 mA. |
81
|
Sun May 16 21:23:02 2021 |
Team | General | ESR OPEN -> preparation for Polarisation Tests |
|