  Laser Cooling Experiment 2021, Page 2 of 5  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Sat May 15 09:50:31 2021, Team, Runs, Laser cooling of....  
H=2
H=7
H=10
Entry  Sat May 15 09:23:52 2021, Sebastian, Accelerator, Ekühler 
Tab "Kühler Elektronenstrahl"
An Gerät schicken
Entry  Sat May 15 09:22:41 2021, Sebastian , Accelerator, Ekühler  IMG-20210515-WA0000.jpgB5FE1031-7FFD-44D3-92B0-75E0784718D9.jpeg
Settings für Ekühler an und aus in SC4 und 
5
Entry  Sat May 15 06:51:16 2021, Night Shift Sebastian/Max/Noah, General, Different Laserscantypes 
We use different scan types (manual scan) or constant laser wavelengths to check the effects of laser cooling in the Schottky diagrams (fluorescence can
not be seen in the detector), for different bunching amplitudes and frequencies:
- Scan from 1028.950 -> 1028.940, stepsize 0.001 every 10 sec
Entry  Sat May 15 03:39:16 2021, Team, General, actual revolution frequency 
frev = 1,2912735 MHz
Entry  Fri May 14 22:20:37 2021, Team, Accelerator, ESR Closed - BEAM #ON! 
 
Entry  Fri May 14 22:04:25 2021, Team, Accelerator, ESR OPEN ; NO BEAM -> Reset cooling device 
we had to open the ESR to reset a cooling device
Entry  Fri May 14 21:43:40 2021, Sebastian, General, "problems accelerator" 
There are cooling problems of some accelerator devices
short break, hopefully :)
Laser is switched of for some rest
Entry  Fri May 14 16:37:01 2021, Benedikt, General, Status update 
Right now, we have to adjust the ion beam a bit to overlap better with the laser beam.
We keep the laser wavelength at resonance with the ions and try to optimize the fluorescence signal on the XUV detector while moving the ion beam.
Entry  Fri May 14 11:01:33 2021, Benedikt, Calibration, Laser Beam adjusted 
The laser beam was adjusted in his position to overlap better with the ions.

Ion beam is destroyed at scraper position 1VO 6 mm and 2VO 4 mm; the laser beam looses half its power at 1VO 6mm and 2VO 4 mm.
Entry  Fri May 14 09:40:04 2021, Nightshift, Runs, Ecooling vs laser wavelength shift, coasting beam, laser stronger than Ecooling IMG-20210514-WA0017.jpg
Last three pictures where taken after 
first laser ion beam overlap adjustments
Entry  Fri May 14 09:38:43 2021, Nightshift, Runs, Coasting beam, ecooler on, scanning laser IMG-20210514-WA0019.jpg
 
Entry  Fri May 14 09:38:04 2021, Nightshift, Runs, Coasting beam, scanning laser, ecooler on IMG-20210514-WA0018.jpg
 
Entry  Fri May 14 09:35:20 2021, Nightshift, Runs, Coasting beam, scanning laser, ecooler on IMG-20210514-WA0018.jpg
 
Entry  Fri May 14 09:00:55 2021, Sebastian, General, UNILAC Problems 
~30 min downtime

--> LASER ADJUSTEMENTS!
Entry  Fri May 14 08:55:53 2021, Sebastian, General, ToDO 14.5 ...so far 
1.) ion lasser overlap and scraper test

2.) change bunching frequency to middle of ecooled coasting beam
Entry  Fri May 14 07:33:42 2021, Team #Night, General, ecooler central frequency shifted relative to bunch central frequency 
 
Entry  Fri May 14 07:20:18 2021, Team #Night, General, actual bunching frequency 
25,82556 MHz
h = 20
Entry  Fri May 14 06:35:55 2021, Team #Night, General, Adjustment of Laser 
we increased the height of the laser beam

TEM Settings
Entry  Fri May 14 06:34:45 2021, Team #Night, Analysis, DSG821 IP 
140.181.104.108