Entry  Wed May 12 08:41:36 2021, Sebastian, Analysis, Laser stability 
During night shift the laser was very stable! Only minor fluctuations occured in the UV
Entry  Wed May 12 08:42:49 2021, Sebastian, Analysis, Laser scans / coastig beam / no ecooler Screenshot_(156).png
Attached you'll see a first laser scan of ~100GHz in the UV.
Entry  Wed May 12 23:45:23 2021, Ken Ueberholz, General, Laser does not reach the exit window 
High rates on the detector at 50mm positions, laser does not seem to reach the exit window.
Entry  Sun May 16 05:09:04 2021, Team, General, Laser cooling with 482ps 
we see laser cooling with 482ps pulse length
Entry  Sun May 16 05:24:00 2021, Team, General, Laser cooling with 285ps 
we also see laser cooling with 285ps pulse length
Entry  Sun May 16 07:03:07 2021, Team, General, Laser cooling with 166ps 
We saw some indications of laser cooling @ 166ps pulse length
Entry  Sat May 15 09:50:31 2021, Team, Runs, Laser cooling of....  
H=2
H=7
H=10
Entry  Wed May 12 22:57:41 2021, Sebastian, General, Laser Reprate 
laser reprate is seven times the revoolution frequency: 9.038283 MHz
pulse length: 735ps
Entry  Sun May 16 22:11:49 2021, Team, General, Laser Polarisation values 
maximal transmission of PBSC (257/514 pbsc was used in combination with xlp12 detector and visual on a screen):

L/4 @ 276° & L/2 @ 348°                -->   p-polarized light
Entry  Fri May 14 11:01:33 2021, Benedikt, Calibration, Laser Beam adjusted 
The laser beam was adjusted in his position to overlap better with the ions.

Ion beam is destroyed at scraper position 1VO 6 mm and 2VO 4 mm; the laser beam looses half its power at 1VO 6mm and 2VO 4 mm.
Entry  Wed May 12 09:04:48 2021, Sebastian, DAQ, Keysight AUtoCal IMG_20210510_143940_resized_20210512_090353546.jpg
 
Entry  Wed May 12 02:16:25 2021, Danyal, Lars, Accelerator, Ion beam position 
Laser Position with scrapers verified. 
1HA: impossible to scratch laser beam, still there at -1.0 mm
2HA: +3mm --> half the laser power on detector; +4.5mm --> gone
Entry  Wed May 12 09:09:15 2021, Sebastian, DAQ, Fluorescence 1029967nm.png
fluorescence with detector in parking position
fixed laser wavelength
electron cooling ON, 
Entry  Mon May 17 08:05:42 2021, Team, General, End of beamtime 
~ 8 a.m.
Entry  Sat May 15 09:22:41 2021, Sebastian , Accelerator, Ekühler  IMG-20210515-WA0000.jpgB5FE1031-7FFD-44D3-92B0-75E0784718D9.jpeg
Settings für Ekühler an und aus in SC4 und 
5
Entry  Sat May 15 09:23:52 2021, Sebastian, Accelerator, Ekühler 
Tab "Kühler Elektronenstrahl"
An Gerät schicken
Entry  Fri May 14 09:40:04 2021, Nightshift, Runs, Ecooling vs laser wavelength shift, coasting beam, laser stronger than Ecooling IMG-20210514-WA0017.jpg
Last three pictures where taken after 
first laser ion beam overlap adjustments
Entry  Thu May 13 02:45:29 2021, Sebastian, Analysis, ESR pressure 8x
 
Entry  Thu May 13 01:55:15 2021, Sebastian, General, ESR amplifier reset / laser check IMG_20210513_014345_resized_20210513_015540959.jpgIMG_20210513_014353_resized_20210513_015541291.jpg
we had to go into the ESR because the amplifiers hooked up. both amplifiers were resetted!

we also checked why we didnt see the laser at the exit window.
Entry  Fri May 14 22:04:25 2021, Team, Accelerator, ESR OPEN ; NO BEAM -> Reset cooling device 
we had to open the ESR to reset a cooling device