ID Date Author Categorydown Subject
  85   Tue May 31 07:29:11 2022 KenDetectorsXUV-Detektor
Rate was very low: ~ 100Hz
Adjusted Walk level and Threshold, new rate: 5kHz
Additionally, parameters of the detector were varied for optimization but were returned to default afterwards.
  3   Tue May 11 16:07:59 2021 SebastianDAQDAQ Manual
Attached you'll find a short manual for operating the whole DAQ system
Attachment 1: DAQ_Manual.pdf
DAQ_Manual.pdf DAQ_Manual.pdf DAQ_Manual.pdf
  14   Wed May 12 09:04:48 2021 SebastianDAQKeysight AUtoCal
Attachment 1: IMG_20210510_143940_resized_20210512_090353546.jpg
IMG_20210510_143940_resized_20210512_090353546.jpg
  Draft   Wed May 12 09:05:48 2021 Keysight SettingsDAQ 
  16   Wed May 12 09:09:15 2021 SebastianDAQFluorescence
fluorescence with detector in parking position
fixed laser wavelength
electron cooling ON, 
BUT we saw strange drifts in the Schottky spectra. It seems to be that these drifts come from the electron cooler! are the drift tubes grounded?

the drifts shift the ion beam over the transition which result in an increase of the XUV anode signal
Attachment 1: 1029967nm.png
1029967nm.png
  19   Wed May 12 10:15:47 2021 Volker HannenDAQUnplugged TDC inputs for MCP front and back
To reduce the load on the VUPROM TDC, we unplugged the TDC inputs for the front and back signals of the MCP of the XUV detector.
The Anode signal is still plugged in and should be sufficient for the analysis.
  28   Wed May 12 23:36:18 2021 Ken UeberholzDAQVI change
carbon main vi - kopie is now in operation

here, in keysight.vi the input settings for the new impedence for the multimeter are now hopefully correct --> THIS SHOULD BE CHECKED IF THE RING IS OPEN 
  30   Thu May 13 00:58:53 2021 DanyalDAQunbunched ion beam
Attachment 1: not_bunched_-_signal.jpg
not_bunched_-_signal.jpg
Attachment 2: not_bunched_-_Schottky.jpg
not_bunched_-_Schottky.jpg
  31   Thu May 13 01:01:27 2021 DanyalDAQbunched ion beam
Attachment 1: bunched_-_signal.jpg
bunched_-_signal.jpg
Attachment 2: bunched_-_Schottky.jpg
bunched_-_Schottky.jpg
Attachment 3: zoom_bunched_-_Schottky.jpg
zoom_bunched_-_Schottky.jpg
  32   Thu May 13 01:05:45 2021 DanyalDAQmore stability by bunching
Because the C3+ part of the ion beam is properly bunched, it is no longer so sensitive to the drifts caused by the e-cooler. 
In the O4+ part of the ion beam these drifts can still be seen. 
  56   Fri May 14 11:01:33 2021 BenediktCalibrationLaser Beam adjusted
The laser beam was adjusted in his position to overlap better with the ions.

Ion beam is destroyed at scraper position 1VO 6 mm and 2VO 4 mm; the laser beam looses half its power at 1VO 6mm and 2VO 4 mm.

EDIT: In the Schottky spectrum, we saw a stronger "cut" from the laser beam with slightly different settings in the TEM system. Later today, we could maybe finetune the ion-laser overlap while observing this "cut".
  11   Wed May 12 08:32:04 2021 SebastianAnalysisfluorescence & energetic overlap
During the night shift we saw several rises of the fluorescence (see another entry) and also energetic overlap in coasting beam modus.
Here the laser wavelength was stabilized @ 1028,967nm and electron cooler was switched off because of some fluctuations which we saw in the schottky.
Left part of the schottky picture shows the c3+ beam, the right part is the o4+ contamination.
Attachment 1: Screenshot_(154).png
Screenshot_(154).png
  12   Wed May 12 08:41:36 2021 SebastianAnalysisLaser stability
During night shift the laser was very stable! Only minor fluctuations occured in the UV
  13   Wed May 12 08:42:49 2021 SebastianAnalysisLaser scans / coastig beam / no ecooler
Attached you'll see a first laser scan of ~100GHz in the UV.
Attachment 1: Screenshot_(156).png
Screenshot_(156).png
  37   Thu May 13 02:45:29 2021 SebastianAnalysisESR pressure
Attachment 1: IMG_20210513_014506_resized_20210513_024017156.jpg
IMG_20210513_014506_resized_20210513_024017156.jpg
Attachment 2: IMG_20210513_014518_resized_20210513_024017559.jpg
IMG_20210513_014518_resized_20210513_024017559.jpg
Attachment 3: IMG_20210513_014524_resized_20210513_024017847.jpg
IMG_20210513_014524_resized_20210513_024017847.jpg
Attachment 4: IMG_20210513_014606_1_resized_20210513_024018452.jpg
IMG_20210513_014606_1_resized_20210513_024018452.jpg
Attachment 5: IMG_20210513_014606_resized_20210513_024018145.jpg
IMG_20210513_014606_resized_20210513_024018145.jpg
Attachment 6: IMG_20210513_014627_resized_20210513_024018757.jpg
IMG_20210513_014627_resized_20210513_024018757.jpg
Attachment 7: IMG_20210513_014636_resized_20210513_024019062.jpg
IMG_20210513_014636_resized_20210513_024019062.jpg
Attachment 8: IMG_20210513_014700_resized_20210513_024019366.jpg
IMG_20210513_014700_resized_20210513_024019366.jpg
  46   Fri May 14 06:34:45 2021 Team #NightAnalysisDSG821 IP
140.181.104.108
  Draft   Wed May 12 02:16:25 2021 Danyal, LarsAcceleratorIon beam position
Laser Position with scrapers verified. 
1HA: impossible to scratch laser beam, still there at -1.0 mm
2HA: +3mm --> half the laser power on detector; +4.5mm --> gone

2VO: interlock, impossible to move (beam diagnostics is informed and will check)
1VO: +0.2mm --> half laser power, +1.2: laser gone (-1.0mm: also gone)

Ion beam adapted to measured laser beam, Target bump position: -22mm (was -18mm before)
Ion beam position verified with scrapers:
1HA: -1.0mm --> still there
2HA: +4.0mm --> beam gone
Target bump angle: unchanged (+1.2 mrad)
  18   Wed May 12 10:14:18 2021 LarsAcceleratorE-Cooler
M.Steck et al. discussed about the E-Cooler and found a possible issue. They asked for enterance to the ESR. Since nobody else was in the HKR and anyway nothing was running because of some other issues, I told, the experiment would not be disturbed and they could enter and do things. (Sth. like putting some repeller electrodes onto hand and other magical things).
It should take about 10 Minutes and might be already finished by now.
  20   Wed May 12 13:11:58 2021 DanyalAcceleratorshort break between 13:30 and 15:30
There will be a short break (2 hours) this afternoon. Between 13:30 and 15:30. 
The so-calles "super lense" in the UNILAC needs to be cleaned (rinsed). 
After that operation should continue as usual. 
  21   Wed May 12 15:36:04 2021 DanyalAcceleratorgeneral power failure in ESR! (everything is off)
The power in the ESR is off. 
(also on the gas-target area on top of ESR)
Electrical engineers are trying to find and fix the problem. 