33
|
Thu May 13 01:13:06 2021 |
Sebastian | General | Bunching frequencies |
relating to Danyals ID 25 post are the current bunching frequencies:
h=2 --> 2,5823668 MHz
h=4 --> 5,1647336 MHz
h=6 --> 7,7471004 MHz
h=7 --> 9,0382838 MHz
h=8 --> 10,3294672 MHz
h=10 --> 12,911834 MHz
h=12 --> 15,4942008 MHz
h=14 --> 18,0765676 MHz
h=16 --> 20,6589344 MHz
h=18 --> 23,2413012 MHz
h=20 --> 25,823668 MHz
h=30 --> 38,735502 MHz |
34
|
Thu May 13 01:21:30 2021 |
Sebastian | General | Current schedule ... so far |
1.) check h=2,4,6,7,8,10 .... bunching frequencies with different amplitudes (signalgenerator), Ecooler ON, Laser OFF --> record schottky and "normal" DAQ
2.) Ecooler ON, Bunching ON, Laser ON (wavelength fixed and/or scanned)
2.1) Do we see the laser in the Schottky? (The laser has to be on the right side of the bunches and act as a barrier to damp the oscillation of the ions inside the buckets.)
If not change laser wavelength until we see the laser in the schottky
2.2) Do we see fluorescence in the XUV Detector signal? Weak fluorescence signal --> check laser-bunch timing by varying the lead delay until we see the highest fluorescence signal.
If we see no fluorescence signal change laser wavelength until we see fluorescence from the xuv anode signal.
3.) Do we see that some sidebands vanish in the schottky? Does the lifetime of the ion beam increase?
3.1.) If not "play" with Laserparameters, scans, delays, etc... |
35
|
Thu May 13 01:55:15 2021 |
Sebastian | General | ESR amplifier reset / laser check |
we had to go into the ESR because the amplifiers hooked up. both amplifiers were resetted!
we also checked why we didnt see the laser at the exit window.
Laser Shutter @ the exit is closed......................... E02VVLF2t needs to be opened! |
Attachment 1: IMG_20210513_014345_resized_20210513_015540959.jpg
|
|
Attachment 2: IMG_20210513_014353_resized_20210513_015541291.jpg
|
|
36
|
Thu May 13 02:42:58 2021 |
Sebastian | General | Lasershutter ESR Entrance?! |
attached should be the name of the entrance laser shutter. just in case somebody will close it ;) |
Attachment 1: IMG_20210513_020027_resized_20210513_024049198.jpg
|
|
38
|
Thu May 13 03:35:25 2021 |
Lars | General | Status: Current schedule ... so far |
1.) so far:
h = 2, 4, 6, 7, 8, 10, 12, 14, 16, 18, 20, 30
Amplitudes: (10, 50, 100, 150, 200, 250) mV
now we will try to use the laser-toy ;-)
> 1.) check h=2,4,6,7,8,10 .... bunching frequencies with different amplitudes (signalgenerator), Ecooler ON, Laser OFF --> record schottky and "normal" DAQ
>
> 2.) Ecooler ON, Bunching ON, Laser ON (wavelength fixed and/or scanned)
>
> 2.1) Do we see the laser in the Schottky? (The laser has to be on the right side of the bunches and act as a barrier to damp the oscillation of the ions inside the buckets.)
> If not change laser wavelength until we see the laser in the schottky
>
> 2.2) Do we see fluorescence in the XUV Detector signal? Weak fluorescence signal --> check laser-bunch timing by varying the lead delay until we see the highest fluorescence signal.
> If we see no fluorescence signal change laser wavelength until we see fluorescence from the xuv anode signal.
>
> 3.) Do we see that some sidebands vanish in the schottky? Does the lifetime of the ion beam increase?
> 3.1.) If not "play" with Laserparameters, scans, delays, etc... |
39
|
Thu May 13 18:34:54 2021 |
Ken Ueberholz | General | What happened scince shift change at 4pm |
Ion frequency shifts with laser, both manually and scanned, without bunches: successful
Bunching with 7 and 20 bunches: successful
Tried laser scans with bunches: unsuccessful
Manual laser scans with bunches: successful |
40
|
Thu May 13 20:18:10 2021 |
Benedikt | General | New f_rev |
The ions were changed to a different speed today at 2 PM. The new revolution frequency is now 1.291278 MHz. |
41
|
Thu May 13 21:00:48 2021 |
Benedikt | General | New reprate of the UV laser |
The lasersystem now operates at a reparte of 9.038946 MHz. This is 7 times f_rev (see previous post).
In the future, the laser-bunch-timing can be adjusted. |
42
|
Thu May 13 23:42:37 2021 |
Ken Ueberholz | General | What was done |
In this shift a number of successful Schottky measurements were done:
With fixed laser wavelength, while varying the wavelength, with different bunching and more (see logfile 1 for more info: line 53 to at least 107).
The detector software sometimes files to change the current of the power supplies, if this happens a simple restart of the GUI fixes the problem.
Once in this shift the Mesytek in the laser lab turned itself (?) off and the background rate increased. Hopefully this was a single event. |
Attachment 1: Schottky1.jpeg
|
|
Attachment 2: Schottky2.jpeg
|
|
Attachment 3: Schottky3.jpeg
|
|
Attachment 4: Schottky4.jpeg
|
|
43
|
Fri May 14 01:28:04 2021 |
Sebastian | General | "new" laser wavelength |
Minor changes in electron cooler voltage (~+13V, now 66903V measured by DMM) leads to that we had to shift the laser wavelength to:
1028,965nm
to see an increase of the countrate of the XUV ANODE Signal.
electron cooler ON
electron cooler current (SET 120mA, HKR "measured" 102mA)
bunched beam, h=20 |
44
|
Fri May 14 01:34:44 2021 |
Team | General | strange XUV Anode signal |
We see a strange behavior of the anode signal when we bunch the ion beam and electron cooler is on.
peak structure... ---> we play now with the bunching amplitude
200mV
150mV
100mV ---> Peaks higher?
see attached file |
Attachment 1: Screenshot_(68).png
|
|
45
|
Fri May 14 04:50:46 2021 |
Team #Night | General | Scraper Tests Ion / Laser Beam |
laser is 4-6mm below the ion beam.
It could be that the interaction between both beams came only from the interaction between the laser halo with the ion beam ?! |
47
|
Fri May 14 06:35:55 2021 |
Team #Night | General | Adjustment of Laser |
we increased the height of the laser beam
TEM Settings
OffsM Ay -0,07
OffsM By -0,35
1VO scratches 6
2VO scratches 3-4 |
48
|
Fri May 14 07:20:18 2021 |
Team #Night | General | actual bunching frequency |
25,82556 MHz
h = 20 |
Draft
|
Fri May 14 07:33:42 2021 |
Team #Night | General | ecooler central frequency shifted relative to bunch central frequency |
|
50
|
Fri May 14 08:55:53 2021 |
Sebastian | General | ToDO 14.5 ...so far |
1.) ion lasser overlap and scraper test
2.) change bunching frequency to middle of ecooled coasting beam
3.) long time measurements see labbook HKR
3.1) try ecooler on/off ; bunch on / off ; laser fixed on / off ; laser scanning on / off ; try different bunching amplitudes (MAX :LEV 0.25V) ; try other h = 10, 7, etc...
3.2) Dont forget to plug in the schottky trigger -> maybe change acquisition and analysis time if needed
4.) XUV detector tests
4.1.) laser - bunch timing by checking xuv anode signal |
51
|
Fri May 14 09:00:55 2021 |
Sebastian | General | UNILAC Problems |
~30 min downtime
--> LASER ADJUSTEMENTS! |
57
|
Fri May 14 16:37:01 2021 |
Benedikt | General | Status update |
Right now, we have to adjust the ion beam a bit to overlap better with the laser beam.
We keep the laser wavelength at resonance with the ions and try to optimize the fluorescence signal on the XUV detector while moving the ion beam. |
58
|
Fri May 14 21:43:40 2021 |
Sebastian | General | "problems accelerator" |
There are cooling problems of some accelerator devices
short break, hopefully :)
Laser is switched of for some rest |
61
|
Sat May 15 03:39:16 2021 |
Team | General | actual revolution frequency |
frev = 1,2912735 MHz |