  33   Thu May 13 01:13:06 2021 SebastianGeneralBunching frequencies
relating to Danyals ID 25 post are the current bunching frequencies:

h=2      -->     2,5823668 MHz
h=4      -->     5,1647336 MHz
h=6      -->     7,7471004 MHz
h=7      -->     9,0382838 MHz
h=8      -->     10,3294672 MHz
h=10     -->     12,911834 MHz
h=12     -->     15,4942008 MHz
h=14     -->     18,0765676 MHz
h=16     -->     20,6589344 MHz
h=18     -->     23,2413012 MHz
h=20     -->     25,823668 MHz
h=30     -->     38,735502 MHz
  34   Thu May 13 01:21:30 2021 SebastianGeneralCurrent schedule ... so far
1.) check h=2,4,6,7,8,10 .... bunching frequencies with different amplitudes (signalgenerator), Ecooler ON, Laser OFF --> record schottky and "normal" DAQ

2.) Ecooler ON, Bunching ON, Laser ON (wavelength fixed and/or scanned)

2.1) Do we see the laser in the Schottky? (The laser has to be on the right side of the bunches and act as a barrier to damp the oscillation of the ions inside the buckets.) 
If not change laser wavelength until we see the laser in the schottky 

2.2) Do we see fluorescence in the XUV Detector signal? Weak fluorescence signal --> check laser-bunch timing by varying the lead delay until we see the highest fluorescence signal. 
If we see no fluorescence signal change laser wavelength until we see fluorescence from the xuv anode signal.

3.) Do we see that some sidebands vanish in the schottky? Does the lifetime of the ion beam increase?
3.1.) If not "play" with Laserparameters, scans, delays, etc...
  35   Thu May 13 01:55:15 2021 SebastianGeneralESR amplifier reset / laser check
we had to go into the ESR because the amplifiers hooked up. both amplifiers were resetted!

we also checked why we didnt see the laser at the exit window.
Laser Shutter @ the exit is closed......................... E02VVLF2t needs to be opened!
Attachment 1: IMG_20210513_014345_resized_20210513_015540959.jpg
IMG_20210513_014345_resized_20210513_015540959.jpg
Attachment 2: IMG_20210513_014353_resized_20210513_015541291.jpg
IMG_20210513_014353_resized_20210513_015541291.jpg
  36   Thu May 13 02:42:58 2021 SebastianGeneralLasershutter ESR Entrance?!
attached should be the name of the entrance laser shutter. just in case somebody will close it ;)
Attachment 1: IMG_20210513_020027_resized_20210513_024049198.jpg
IMG_20210513_020027_resized_20210513_024049198.jpg
  38   Thu May 13 03:35:25 2021 LarsGeneralStatus: Current schedule ... so far
1.) so far: 
h = 2, 4, 6, 7, 8, 10, 12, 14, 16, 18, 20, 30
Amplitudes: (10, 50, 100, 150, 200, 250) mV

now we will try to use the laser-toy ;-)


> 1.) check h=2,4,6,7,8,10 .... bunching frequencies with different amplitudes (signalgenerator), Ecooler ON, Laser OFF --> record schottky and "normal" DAQ
> 
> 2.) Ecooler ON, Bunching ON, Laser ON (wavelength fixed and/or scanned)
> 
> 2.1) Do we see the laser in the Schottky? (The laser has to be on the right side of the bunches and act as a barrier to damp the oscillation of the ions inside the buckets.) 
> If not change laser wavelength until we see the laser in the schottky 
> 
> 2.2) Do we see fluorescence in the XUV Detector signal? Weak fluorescence signal --> check laser-bunch timing by varying the lead delay until we see the highest fluorescence signal. 
> If we see no fluorescence signal change laser wavelength until we see fluorescence from the xuv anode signal.
> 
> 3.) Do we see that some sidebands vanish in the schottky? Does the lifetime of the ion beam increase?
> 3.1.) If not "play" with Laserparameters, scans, delays, etc...
  39   Thu May 13 18:34:54 2021 Ken UeberholzGeneralWhat happened scince shift change at 4pm
Ion frequency shifts with laser, both manually and scanned, without bunches: successful
Bunching with 7 and 20 bunches: successful
Tried laser scans with bunches: unsuccessful
Manual laser scans with bunches: successful
  40   Thu May 13 20:18:10 2021 BenediktGeneralNew f_rev
The ions were changed to a different speed today at 2 PM. The new revolution frequency is now 1.291278 MHz.
  41   Thu May 13 21:00:48 2021 BenediktGeneralNew reprate of the UV laser
The lasersystem now operates at a reparte of 9.038946 MHz. This is 7 times f_rev (see previous post).

In the future, the laser-bunch-timing can be adjusted.
  42   Thu May 13 23:42:37 2021 Ken UeberholzGeneralWhat was done
In this shift a number of successful Schottky measurements were done:
With fixed laser wavelength, while varying the wavelength, with different bunching and more (see logfile 1 for more info: line 53 to at least 107).
The detector software sometimes files to change the current of the power supplies, if this happens a simple restart of the GUI fixes the problem.
Once in this shift the Mesytek in the laser lab turned itself (?) off and the background rate increased. Hopefully this was a single event.
Attachment 1: Schottky1.jpeg
Schottky1.jpeg
Attachment 2: Schottky2.jpeg
Schottky2.jpeg
Attachment 3: Schottky3.jpeg
Schottky3.jpeg
Attachment 4: Schottky4.jpeg
Schottky4.jpeg
  43   Fri May 14 01:28:04 2021 SebastianGeneral"new" laser wavelength
Minor changes in electron cooler voltage (~+13V, now 66903V measured by DMM) leads to that we had to shift the laser wavelength to:

1028,965nm 

to see an increase of the countrate of the XUV ANODE Signal.

electron cooler ON
electron cooler current (SET 120mA, HKR "measured" 102mA)
bunched beam, h=20
  44   Fri May 14 01:34:44 2021 TeamGeneralstrange XUV Anode signal
We see a strange behavior of the anode signal when we bunch the ion beam and electron cooler is on.

peak structure... ---> we play now with the bunching amplitude 

200mV
150mV
100mV ---> Peaks higher?

see attached file
Attachment 1: Screenshot_(68).png
Screenshot_(68).png
  45   Fri May 14 04:50:46 2021 Team #NightGeneralScraper Tests Ion / Laser Beam
laser is 4-6mm below the ion beam.
It could be that the interaction between both beams came only from the interaction between the laser halo with the ion beam ?!
  47   Fri May 14 06:35:55 2021 Team #NightGeneralAdjustment of Laser
we increased the height of the laser beam

TEM Settings
OffsM Ay -0,07
OffsM By -0,35

1VO scratches 6
2VO scratches 3-4
  48   Fri May 14 07:20:18 2021 Team #NightGeneralactual bunching frequency
25,82556 MHz
h = 20
  Draft   Fri May 14 07:33:42 2021 Team #NightGeneralecooler central frequency shifted relative to bunch central frequency
  50   Fri May 14 08:55:53 2021 SebastianGeneralToDO 14.5 ...so far
1.) ion lasser overlap and scraper test

2.) change bunching frequency to middle of ecooled coasting beam

3.) long time measurements see labbook HKR
3.1) try ecooler on/off ; bunch on / off ; laser fixed on / off ; laser scanning on / off ; try different bunching amplitudes (MAX :LEV 0.25V) ; try other h = 10, 7, etc...
3.2) Dont forget to plug in the schottky trigger -> maybe change acquisition and analysis time if needed

4.) XUV detector tests
4.1.) laser - bunch timing by checking xuv anode signal
  51   Fri May 14 09:00:55 2021 SebastianGeneralUNILAC Problems
~30 min downtime

--> LASER ADJUSTEMENTS!
  57   Fri May 14 16:37:01 2021 BenediktGeneralStatus update
Right now, we have to adjust the ion beam a bit to overlap better with the laser beam.
We keep the laser wavelength at resonance with the ions and try to optimize the fluorescence signal on the XUV detector while moving the ion beam.
  58   Fri May 14 21:43:40 2021 SebastianGeneral"problems accelerator"
There are cooling problems of some accelerator devices
short break, hopefully :)
Laser is switched of for some rest
  61   Sat May 15 03:39:16 2021 TeamGeneralactual revolution frequency
frev = 1,2912735 MHz