ID Date Author Category Subjectup Text Attachments
  50   Fri May 14 08:55:53 2021 SebastianGeneralToDO 14.5 ...so far1.) ion lasser overlap and scraper test

2.) change bunching frequency to middle of
  
  51   Fri May 14 09:00:55 2021 SebastianGeneralUNILAC Problems~30 min downtime

--> LASER ADJUSTEMENTS!
  
  70   Sun May 16 02:18:53 2021 SebastianGeneralUV Drop1:25 a.m. huge drop in UV laser power
-> small crystal bump with both y screws
of bbo oven
  
  19   Wed May 12 10:15:47 2021 Volker HannenDAQUnplugged TDC inputs for MCP front and backTo reduce the load on the VUPROM TDC, we unplugged
the TDC inputs for the front and back signals
of the MCP of the XUV detector.
  
  28   Wed May 12 23:36:18 2021 Ken UeberholzDAQVI changecarbon main vi - kopie is now in operation

here, in keysight.vi the input settings for
  
  39   Thu May 13 18:34:54 2021 Ken UeberholzGeneralWhat happened scince shift change at 4pmIon frequency shifts with laser, both manually
and scanned, without bunches: successful
Bunching with 7 and 20 bunches: successful
  
  42   Thu May 13 23:42:37 2021 Ken UeberholzGeneralWhat was doneIn this shift a number of successful Schottky
measurements were done:
With fixed laser wavelength, while varying
 Schottky1.jpegSchottky2.jpegSchottky3.jpegSchottky4.jpeg 
  85   Tue May 31 07:29:11 2022 KenDetectorsXUV-DetektorRate was very low: ~ 100Hz
Adjusted Walk level and Threshold, new rate:
5kHz
  
  48   Fri May 14 07:20:18 2021 Team #NightGeneralactual bunching frequency25,82556 MHz
h = 20
  
  61   Sat May 15 03:39:16 2021 TeamGeneralactual revolution frequencyfrev = 1,2912735 MHz   
  6   Tue May 11 20:14:43 2021 DanyalGeneralbad ESR vacuumI just heard that the ESR vacuum is quite
bad. 
There was a small vacuum problem a while
  
  31   Thu May 13 01:01:27 2021 DanyalDAQbunched ion beam   bunched_-_signal.jpgbunched_-_Schottky.jpgzoom_bunched_-_Schottky.jpg 
  Draft   Fri May 14 07:33:42 2021 Team #NightGeneralecooler central frequency shifted relative to bunch central frequency    
  5   Tue May 11 18:29:35 2021 DanyalGeneralfirst ions in the ESR   first_ions_are_injected.jpg 
  11   Wed May 12 08:32:04 2021 SebastianAnalysisfluorescence & energetic overlapDuring the night shift we saw several rises
of the fluorescence (see another entry) and
also energetic overlap in coasting beam modus.
 Screenshot_(154).png 
  25   Wed May 12 22:35:33 2021 DanyalGeneralfrev and fbSchottky frequency (189th harmonic) = 244.033662
MHz
  
  21   Wed May 12 15:36:04 2021 DanyalAcceleratorgeneral power failure in ESR! (everything is off)The power in the ESR is off. 
(also on the gas-target area on top of ESR)
Electrical engineers are trying to find and
  
  8   Wed May 12 02:34:29 2021 DanyalGeneralinstabilities in ion frequencyThe ion beam moves around, pretty arbitrary.
See picture. 
ESR crew believes that it is not due to fluctuations
 fluctuations.jpg 
  10   Wed May 12 08:10:17 2021 LarsGeneralinstabilities in ion frequencylooks like the E-Cooler is responsible for
this. If one turns off the electron current,
the beam stays stable. 
  
  32   Thu May 13 01:05:45 2021 DanyalDAQmore stability by bunchingBecause the C3+ part of the ion beam is properly
bunched, it is no longer so sensitive to
the drifts caused by the e-cooler. 
  
ELOG V3.1.5-fc6679b