Entry  Sat Mar 29 15:51:46 2025, CG, JG, MC, ID, General, DAQ setup 
********************************************
** Setup of DAQ x86l-131 (outside pocket) **
********************************************
Entry  Sat Mar 29 17:19:46 2025, CG, JG, MC, ID, General, Sample data file 
Data files written to /mnt/raw.data/e0203_e0018.

From MBS computers:
Entry  Sat Mar 29 17:53:13 2025, CG, ID, MC, Electronics, Bias remote control 
The MHV modules are set up for remote control. This can be accessed via the mesycontrol software running on x86l-128.

A configuration file has been save to: esr/usr/litv-exp/DAQ-control/mesycontrol/pleiades_2025_v2.xml
Entry  Mon Mar 31 17:55:16 2025, JG, DAQ, DAQ overview 
The DAQ is running of 4 different nodes/PCs, that can be accessed by ssh using the user litv-exp.

[TABLE border="1"]
Entry  Mon Mar 31 18:21:37 2025, JG, DAQ, ESR scaler mapping 
This is the list of scaler channels used at the VME ESR DAQ on x86l-204:

[TABLE border="1"]
Entry  Mon Mar 31 18:35:46 2025, JG, DAQ, lmd files on ESR NAS 
The files of each MBS node or the timesorter are written to the ESR NAS by the RFIO server.
The server is running on the virtual machine atprfio.gsi.de. 
The NAS is mounted there and we write data to the subfolder: /mnt/raw.data/e0203_e0018/
Entry  Tue Apr 1 17:18:10 2025, ID, MC, CJG, Detectors, Both PLEIADES detectors in beam 
We started inserting the inside and outside detector, see
https://elog.gsi.de/esr/E0203_E0018/46
Entry  Tue Apr 1 22:41:52 2025, CG, Detectors, Climbing leakage currents highLeakageCurrents.png
The experiment has been running stably during the afternoon.
DAQ rates have remained constant and the frequency of hits in the Go4 has remained 1 hit every ~few mins.
Entry  Tue Apr 1 23:00:41 2025, CG, General, Run stopped and detectors moved back 
Due to the continued rise in leakage currents, I have stopped the run, moved the detectors completely back and turned off the 
bias to all detectors.
Entry  Thu Apr 3 13:09:28 2025, JG, DAQ, 194Pb MBS settings 
The settings of the MBS daq during the first data taking with fragments around 194Pb (W.Korten experiment) was not entirely correct:

1. both FEBEX nodes had the very same sub-sytem identifier 0x200. The timesorter did merge the two data streams into the lmd files. Now the events cannot
Entry  Thu Apr 3 13:24:31 2025, CG, Detectors, Bias problem diagnosing 
During an access break to the ESR, I made a few tests with the bias scheme to see if we could better understand some of the weird quirks.

Two detectors showed likely shorts during initial setup - these detectors were still cabled to the bias network though. 
Entry  Thu Apr 3 14:53:13 2025, ID, Detectors, Link to leakage current Google doc 
Please enter the leakage currents from the mesycontrol every ~1h into this Google document:

https://docs.google.com/spreadsheets/d/1Gt1tFHwn4XFrJ5_-nQvTi635UD0aHgN6gCdXDTHQdkI/edit?gid=299353113#gid=299353113
Entry  Thu Apr 3 17:37:04 2025, CJG, GL, MC, General, Detectors in position, taking data 
The inner detector was moved into position.
The device control for the outer detector is not responding and I am not an expert/don't know how to make it work.
Entry  Fri Apr 4 16:12:36 2025, CJG, GL, MC, JG, ID, General, Moving PLEIADES in 
186Hf now stored stably in the ring.

Will move both detectors in to position.
Entry  Fri Apr 4 16:27:11 2025, CJG, GL, MC, JG, ID, General, PLEIADES in position 
Inner PLEIADES detector moved into position at +2mm.
Again, the outside pocket cannot be moved.