Entry  Thu May 16 14:52:45 2024, Shahab, DAQ, Zr recording 
Recording Zr starting from 14:45 again back to short cycle.
Entry  Fri May 17 23:30:16 2024, Shahab, General, HHT people inside 
no beam since about one hour, also HHT people inside since about 10 min.
Entry  Sat May 18 00:06:56 2024, Shahab, Runs, HHT people out again 
we try to re run the ESR. ESR behaves very strangely. Something not so right.
Entry  Thu May 16 11:20:10 2024, Sergey, Accelerator, Screenshot of ESR pattern with 140 repetitions (each is 100 ms) 2024-05-16_11-19-01-545.png
Injection Beam Process: 100ms
Bunching Beam Process: 16ms
Intermediate Beam Process: 100 ms, which is repeated 140 times
Entry  Thu May 16 12:48:58 2024, Sergey, Accelerator, Tune to 98Zr 
- stop longer measurements
- change quadrupole and sextupole magnets
- rescale SIS-TE-ESR
Entry  Tue May 14 15:07:23 2024, Ruijiu, David, Shahab, Xinliang, Zhangmin, Runs, Cooler curve measurement 7x


Cooler curve measurement
Entry  Mon May 6 12:16:09 2024, Ruijiu Chen, DAQ, ntcap scaler ScalerSignalMap20240515.pdf
 
Entry  Thu May 9 10:01:59 2024, Ruijiu Chen, DAQ, NI crate of NTCAP system can not be started. VID_20240508_113353.mp4dc36252cc5b2262cb6eab099009f16ed.mp4comparision_iq.jpgcomparision_sc.jpgcomparision_sc.png
After moving the NTCAP system from HKR to ESR Messhutte, we tested the system with a signal generator on 16th February and confirmed that it was functioning
correctly.
Entry  Thu May 9 15:59:30 2024, Ruijiu Chen, DAQ, Carsten checked the NTCAP system. 
Exactly this was the question. If several devices fail at the same time and you look for the course you might get suspicious.
 
Anyhow,
Entry  Sun May 12 18:34:54 2024, Ruijiu, Analysis, How to use queqiao to transfer tiq data start_OnlineDataAnalysis.jpgqueqiao_rsa.jpg
If the ssh to lxir131 was disconnected, you can connect to lxir131 and restart queqiao program to transfer tiq data from NAS to luster.

1. Open a terminal on any GSI linux computer, like the one in the Measurement Room:
Entry  Mon May 20 09:01:51 2024, Oliver, Jelena, General, Shift news 
Data collection runs smooth so far.

Yuri Litvinov will start modifying SP magnets now. The resolution will change.
Entry  Thu May 16 07:25:33 2024, Mayr, Hannes, Runs, Lassie Screenshot 07:23 2024-05-16_07-23-30-208_tcl1064.png
Start of regular screenshots of the Lassie monitor every 1-2 hours.
Entry  Thu May 16 07:50:39 2024, Mayr, Hannes, Runs, Peaks with very high particle rate 2024-05-16_07-49-53-757_tcl1064.png
Peaks in the particle diagram going to unusual high 1.4e9 particles.
Entry  Thu May 16 08:58:39 2024, Mayr, Hannes, Runs, Fluctuations in particle rate 2024-05-16_08-58-00-964_tcl1064.png
Particle rates are fluctuating and increasing from a constant 5e8 to something around 1e9.
Entry  Thu May 16 09:41:56 2024, Mayr, Hannes, Runs, No beam 
No beam from 09:39 to 10:10 due to a setting change. The change aims to increase the measurement time to 10s.
Entry  Thu May 16 10:18:14 2024, Mayr, Hannes, Runs, Beam back, DAQ off 
Beam is back since 10:10, but DAQ is turned off to change the setting there.
Measurements starting at 10:18 are only test runs and should not be used for analysis.
Entry  Thu May 16 11:08:27 2024, Mayr, Hannes, Runs, DAQ running again 
"Real" measurement with good data starting from 11:07 until approximately 13:00.
Measurement time was changed to 10s with injections every 32s.
Entry  Thu May 16 11:13:05 2024, Mayr, Hannes, Runs, Rates 2024-05-16_11-10-57-933_tcl1064.png
With the new timing, the rates now look like can be seen in the screenshot.
Entry  Thu May 16 13:04:02 2024, Mayr, Hannes, Runs, DAQ stopped, change setting to 98Zr 
Beam tuning for 98Zr starting at 12:53, following data should be excluded from analysis. DAQ was stopped around 13:13.
Entry  Sun May 19 12:04:55 2024, Kanika, Accelerator, Beam back 
The beam is back.