  30   Fri Jun 20 15:58:21 2025 Wilfried, Konstantin, SimonLaserLaser stepwidthFrom previous Bi-Beamtimes, we expect the
width of the transition to be >50GHz (FWHM).
The current step width is 0.002nm which corresponds
  
  31   Sat Jun 21 00:23:22 2025 RodolfoLaserDyeI have prepared new (fresh) dye solutions
of Fluorescein 27: 2 charges. They are in
the Safety Cabinet (Sicherheitsschrank) in
 Farbstoff_FL27.jpg 
  34   Sat Jun 21 02:32:24 2025 Alex, Anton, Rodolfo, Hiroshi, CarstenLaserLaser scanning settingThis is the initial scanning range
[LIST]
[*] 3 Loops
  
  35   Sat Jun 21 03:06:19 2025 Rodolfo, Alex, Hiroshi, AntonLaserbeam overlap with t-scrapers[TABLE border="1"]
motor|ion beam position (mm) from outside|ion
beam position (mm) from inside
 2025-06-21_05-14-39-706.png2025-06-21_05-22-21-447.png2025-06-21_05-27-59-895.png2025-06-21_05-31-37-019.pngMRC-settings_Th-Beam_2025-06-21.JPG 
  37   Sat Jun 21 07:28:35 2025 Arya, Julien, WilfriedLaserLaser TimingWe roughly adjusted the timing based on attachment
1, for ions to be in center of electron cooler
(east arc), corrected for PMTs being 2.5m
 Bildschirmfoto_IonBunch_PDs_2025-06-21.pngBildschirmfoto_rough_timing_2025-06-21_07-22-59.pngBildschirmfoto_timingcorrected_2025-06-21_08-21-53.pngBildschirmfoto_timing_final_2025-06-21_08-46-18.png 
  51   Mon Jun 23 10:52:34 2025 Julian, Lukas, Zsolt, Nadine, KonstantinLaserFrequency conversion unitWe exchanged the old BBO of the Cobra's FCU
with a new one. The output power of the Cobra
was around 120mJ. In the end, we achieved
  
  60   Wed Jun 25 05:53:54 2025 RodolfoLaserFCUCobra's FCU was recalibrated. Table saved
as FCU_547-554_RS_2024-06-25.fcu.
  
  66   Fri Jun 27 06:55:45 2025 Esther. KonstantinLaserLaser-ion overlapWe cross-checked the laser-ion superposition
by using the T-scrapers. We did it only after
the scans in order to do not change the duty
 2025-06-27_06-52-01-807.png2025-06-27_07-12-27-135.png2025-06-27_07-32-28-599.png2025-06-27_07-51-52-620.png 
  39   Sat Jun 21 11:42:50 2025 Arya, Julien, WilfriedGeneralTest laser scanTest scan to see whether laser spot is moving
while scanning
  
  44   Sun Jun 22 11:31:59 2025 Arya, Carsten, Julien, KonstantinGeneralSummary morning shift1. UNILAC running again, so we resumed the
beam tuning wherre we stopped yesterday at
14:00
  
  1   Tue May 20 16:14:30 2025 Rodolfo, SimonDetectorsPMT arrangement at ESRThis is the arrangement of the photomultipiers
at the optical detection region at ESR for
Thorium 2025
 PMT_Arrangement_2025-05-20.jpg 
  2   Mon Jun 2 16:36:57 2025 CarstenDetectorsMesycontrolssh -Y litv-exp@x86l-204
'mesycontrol'
 MSCF16-F-V.pdf 
  3   Wed Jun 4 16:17:47 2025 SimonDetectorsNitrogenThe nitrogen supply for the PMTs is turned
[B]ON[/B].
  
  4   Wed Jun 4 16:18:57 2025 Rodolfo, SimonDetectorsPMT dark count ratesI adjusted the offsets of the amplifiers in
the cave and measured the dark count rates
  
  7   Wed Jun 11 16:44:39 2025 Carsten, JanDetectorsDetector voltages and thresholds for DAQ2 (Mesycontrol)Voltages (2650v) for the small band 9423 is
ok. Signals are nicely separated from background,
thresholds can be easily set.
 Mesytec_CFD_Settings_2025-06-11_17-17-33.png 
  13   Mon Jun 16 21:47:23 2025 Carsten, Wilfried, Simon DetectorsNew threshold values for PMTsWe adjusted the thresholds for the PMTs and
increased the voltage of PMT middle to 2.7kV
  
  36   Sat Jun 21 03:13:02 2025 Alex, Anton, Rodolfo, HiroshiDetectorsPart Det SouthBunch signal on Particle Detector South. On
the 
 Bildschirmfoto_PartDetSouth_2025-06-21.png 
  40   Sat Jun 21 17:00:10 2025 Carsten, Peter, Danyal, Kristian, MarekDetectorsPMT north exchangedWe noted that the dark countrate of PMT north
is about 20x higher than that of PMT middle.
 Panel4.pngPanel4.jpg 
  41   Sat Jun 21 18:00:49 2025 Carsten, Peter, Danyal, Kristian, Marek DetectorsPMT signalsCarsten and Kristian changed (18:00) the thresholds
of PMT north and PMT middle in the ESR cave.
 Panel4.gif 
  42   Sat Jun 21 21:55:18 2025 Peter, Danyal, MarekDetectorsPMT ratesWe have made two foam rings (outer diameter
ca. 70 mm with a thickness of 10 mm each
and placed them successively underneath PMT
 no_rings_under_PMT_north.png2_rings_under_PMT_north.png 