Wed Feb 5 14:05:53 2025, Rodolfo, Sebastian, Analysis, Schirm / Iris ESR Entrance Fenster
|
Wegen defekt von Kippschirm wurde das alte System zum Verstellen der Iris und des Schirms für das ESR Eintrittsfensters genutzt.
Fleischmann Trafo:
|
Mon Mar 3 05:17:20 2025, Sebastian, Denise, Benedikt, Runs, Scanbereich 257.175 nm - 257.675 nm
|
[TABLE border="1"]
Zeit | Scanbereich (nm) | Anzahl Laserschritte | Start LMD | Stop LMD | Messdauer (s) | Elektronenkuehlung (s) | Kommentar
|-
|
Sat Mar 1 17:43:18 2025, Reinhold, Jens, Natalya, Danyal, Denise, Benedikt, DAQ, Scanbereich 257.175 nm - 257.675 nm
|
[TABLE border="1"]
Zeit | Scanbereich (nm) | Anzahl Laserschritte | Start LMD | Stop LMD | Messdauer (s) | Elektronenkuehlung (s) | Kommentar
|-
|
Sat Mar 1 16:33:22 2025, Konstantin, DAQ, Restart of Go4 
|
Restart of go4 before new scan:
1. Stop Acquisition (Stop button right next to the green play buttons)
|
Wed Jan 29 10:23:21 2025, Sebastian, General, Remote Control Schirm Nord West Tower
|
Box zum rein und rausfahren hinter Laser PC im ESR
Zeiger von Rädchen muss auf "SCHIRM NW" stehen
|
Tue Jan 28 14:13:54 2025, Benedikt & Sebastian TEAMWORK DIGGA, DAQ, RedPitaya Adresse
|
SCPI Server:
http://169.254.204.79/
|
Mon Jan 27 10:59:22 2025, Sebastian, DAQ, RedPitaya
|
[B]Hostname: ext-91000370132.gsi.de
IP-Adresse: 10.100.3.106
[/B]
|
Thu Feb 27 21:23:02 2025, Jens, DAQ, Python Data Channels
|
Python variables and names in DAQ
Because the Name of variables in DAQ doesnt match the the real variables, here is List of the channels and what value is in this channel
|
Fri Feb 28 00:19:04 2025, Konstantin, Sebastian, Detectors, PMT power supply
|
We checked the PMT signal inside the cave by using the local HV power supply. If one needs to repeat the measurement at another time, be careful to use
the correct HV power supply, since the second one, which is mounted in the crate has the wrong polarity. Both PMT's must be supplied with a negative voltage.
|
Sat Mar 1 03:45:07 2025, Denise, Benedikt, Sebastian, DAQ, PH100 Gentecs @ Medusa
|
Die zwei PH100 Messkoepfe am Nordwest und Suedwest Tower werden delayed in Medusa angezeigt und die Daten werden nicht an Medusa geschickt.
Letzteres haengt wohl mit den benoetigten 10 digits zusammen die MBS erwartet.
|
Fri Jan 31 16:37:39 2025, Sebastian, DAQ, PD Nord
|
PD Nord an ESR Panel PMT Süd verkabelt |
Mon Jan 27 11:06:21 2025, Sebastian, General, Optiken ESR Lab, NW und SW eingebaut
|
Die Optiken (Layertec 2" und 3") ab TEM Spiegel ESR Lab
bis ESR TEM Spiegel eingebaut.
|
Sat Mar 1 19:19:25 2025, Konstantin, DAQ, Offline Analysis 
|
A copy of the current go4 analysis is placed at atplaser@lxgs1055:/kr_analysis. Use the usual Go4 startup routine to start an offline analysis of data.
They should be copied into the folder lxgs1055:/data.local2/E0075. To combine different
lmd-files, simply create a file like "FirstScan.lml" containing the paths of the individual files. After this you can read the lml file with go4. |
Sun Mar 2 18:55:30 2025, Jens, Reinhold, Danyal, DAQ, Main Scan range (4 blocks) shifted by -0.0012 nm --> one more scan
|
We decided to scan the main range, shifted by -0.0012nm, one more time in order to have the non-shifted AND the shifted range both 3x !
[TABLE border="1"]
|
Sat Mar 1 04:02:59 2025, Denise, Benedikt, Sebastian, DAQ, Lokale Datenaufnahme auf LXG1049
|
Die Daten werden LOKAL auf dem LXG1049 unter folgendem Verzeichnis gespeichert:
[B]/data.local2/2025_krypton/[/B]
|
Mon Mar 3 01:58:27 2025, Sebastian, Denise, Benedikt, Runs, Lebensdauer Ionen 7x
|
Lebensdauer der Ionen wurde für etwa 1000s vermessen ohne Laser
(geblockt)
-> XUV Anode und DC Trafo
|
Thu Feb 27 09:38:04 2025, Konstantin & Danyal, Detectors, Laufzeit Messungen
|
Gestern Abend haben wir die Signal Laufzeiten im gemessen:
PMT Mitte: 1213 ns (bis zur Messhütte ohne DAQ sind es 1025 ns)
|
Fri Feb 28 17:18:34 2025, Tamina, General, Laserwellenlängen zur Orientierung
|
Minimale Wellenlänge: IR 1028,7 nm --> 257,175 nm im UV (DFB Temperatur sollte ca. be 16,5 °C sein)
Maximale Wellenlänge: IR 1030,7 nm --> 257,675 nm UV (DFB TEmperatur sollte ca. bei 35,6 °C sein)
|
Fri Feb 28 05:53:59 2025, Denise, Sebastian, Benedikt, Calibration, Laserstrahllage mit Scraper
|
Laserstrahl mit Hilfe der Blenden eingestellt, dann mit Scrapern vermessen
|
Tue Mar 4 04:17:14 2025, Denise, Sebastian, Benedikt, Calibration, Laserstrahllage mit Scraper
|
da der Unilac und SIS18 einen Interlock geworfen haben befanden sich von 3:50 Uhr bis 4:20 Uhr keine Ionen im ESR
mit den Scrapern und der Kamera im SW wurde etwa die Strahllage des Laserstrahls vermessen (optisch bei etwa der zentralen Wellenlänge von 1029.7nm)
|