  laser spectroscopy on Be-like Kr, Page 4 of 6  Not logged in ELOG logo
ID Date Author Category Subjectdown Text Attachments
  73   Sat Mar 1 18:32:05 2025 JensRunsLaser während Scan18:30Uhr:
Timestamp im Programm hat gehangen. Kurz
im Anzeigefeld markieren und es ging wieder.
  
  68   Sat Mar 1 11:40:17 2025 Tamina, Florian, KonstantinCalibrationLaser positionThe laser position stayed perfect after the
scans. See picture.
 Screenshot_2025-03-01_11-39-32.png 
  56   Fri Feb 28 19:33:03 2025 VolkerDetectorsLaser backgroundWe measured the laser background rate in the
XUV detector.
The voltages applied were +300V at the MCP
  
  43   Fri Feb 28 00:18:16 2025 TaminaGeneralKalibration UV Monitor im LaserlaborDer UV Monitor steht in der Reflexion des
PBSC auf dem Lasertisch im Laserlabor. 
  
  11   Tue Jan 28 15:57:05 2025 DeniseGeneralJustage: ESR Labor Periskop Spiegel obenobere Schraube nach rechts drehen, dann bewegt
sich Laserspot nach links 
selbe Schraube nach links dann Laser rechts
  
  86   Mon Mar 3 08:02:00 2025 DanyalAcceleratorIonenenergie wird geändertHallo zusammen,

wir haben den Scan-Bereich vom Laser - bei
  
  50   Fri Feb 28 13:53:06 2025 Tamina, RodolfoRunsIonenbunchSignal of PMT-Mitte. Recorded with an unstable
ion bunch. With approx. 3E8 Ions
 Screenshot_Kr_Ionenbunch_2025-02-28_1350.pngScreenshot_Kr_Ionenbunch_2025-02-28_1445.png 
  18   Thu Feb 6 12:54:29 2025 DanyalAcceleratorHV-divider for electron cooler connected - readout is runningThe HV-divider has been connected to the E-Cooler.

 HV_divider_readout.jpg 
  36   Thu Feb 27 09:59:08 2025 KonstantinCalibrationHV-DividerThe readout of the HV divider runs on a RaspberryPi
inside the HV-cave of the electron cooler.
Starting from 2025-02-27 09:42, the divider
  
  52   Fri Feb 28 15:53:44 2025 KonstantinAcceleratorHF Signal for BunchingThe HF Bunching Frequency is: 1.7838817 MHz

Given (read) by the ESR operators in HKR.
  
  39   Thu Feb 27 16:30:57 2025 Konstantin und RodolfoDAQHF SignalWe have exchanged the HF-Signal in the DAQ
Electronic: from Dummy-HF to the real HF
from accelerator. 
  
  70   Sat Mar 1 13:45:42 2025 Konstantin DAQGentec readoutGentec readout is now included in the general
slow data acquisition. The issue was that
the buffer of the power meter was not emptied
  
  101   Tue Mar 4 08:35:45 2025 Denise, Benedikt, SebastianCalibrationGentec Kalibrationen im ESRGentec NW (PH100 S:UV) OD.3 
[TABLE border="1"]
Leistung Gentec PH100 NW/ mW|0.475 | 0.961
  
  47   Fri Feb 28 04:47:39 2025 Denise, Sebastian, BenediktCalibrationGentec ESR KalibrationUnsicherheiten Gentecs im allgemeinen bei
etwa 6.5%
  
  79   Sun Mar 2 08:18:25 2025 Tamina, Volker, Florian, RodolfoGeneralFrühschicht Die Frühschicht scan weiter. Siehe Eintrag
75 (noch als Draft)
  
  87   Mon Mar 3 08:33:00 2025 Tamina, Florian, Volker und Rodolfo GeneralFruehsichtDie Fruehsicht macht den letzten Scan, bevor
die Ionenenergie geaendert wird.
  
  28   Mon Feb 17 13:49:20 2025 DeniseGeneralFrequenzbreiten IonensystemBerechnung der Frequenzbreiten des Lasers
im Ionensystem 
Werte für die Frequezbreiten des Lasers aus
  
  51   Fri Feb 28 15:30:41 2025 Tamina, RodolfoDetectorsFast PD Nord WestWe had an issue with the PD NW. The signal
after the Rate Divider was not OK.
  
  88   Mon Mar 3 08:52:19 2025 Tamina, Rodolfo, Volker, Danyal, FlorianRunsExtended Scan 257.0574 nm - 257.8022 nm bei hoeherer IonenenergieNeue Umlauffrequenz: 1.78561578504741 MHz
rep freq laser :  3.57123157001
ecooler voltage: 157823 V
  
  90   Mon Mar 3 13:00:51 2025 DanyalGeneralExperiment will end tomorrow (04.03), at 08:00 AM preciselyThe experiment will end tomorrow (04.03) at
08:00 AM precisely. 
Everything (magnets, RF, etc) will be shut
  