  162   Fri Apr 4 17:13:12 2025 Team PleiadesDetectorsPLEIADES detector out
17:12 We moved the PLEIADES detector out, both are outside now (in parking position)
  161   Fri Apr 4 17:10:35 2025 H. Weick, S. LitvinovAcceleratorESR scraper setting
the new scraper setting for good isochronicity but still acceptable intensity losses is:
Done at ~ 15:00 today.
GEEXDS1HA (outside)          =  -8 mm
GEEXDS1HG (ToF-det-aperture) =  20.5 mm
GE01DS3HG                    = -84.2 mm  (fully open is -130 mm)
in addition, a detector pocket is in GE01DD2IG = 1.7 mm
  160   Fri Apr 4 17:04:39 2025 H. Weick, S. LitvinovAcceleratorslits after target, Bio_REM alarm
A Bio-REM detector on the roof of ESR caused an alarm and shut down the whole accelerator.
Too much primary beam going to ESR, noe we avoid it by catching the primary beam at TE4 slits.
The distribution on current grids looks liek in the LISE simulation, we cut at 5mm.
The beam come sin three charge states tehouter ones 82+, 81+ anyway do not make it to ESR, we need to cut also the 80+ at least half.
Then the dose rate on ESR roof is much lower 0.8 uSv/h -> 0.2 uSv/h.
  159   Fri Apr 4 16:59:25 2025 KK BJDAQLassie screen shots
  158   Fri Apr 4 16:24:48 2025 Ruijiu, YuriAnalysisPID of 186Hf
Code used to add up injection data.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/2025.04.04.13.00$ find /data.local/G22-00018_00203/results/analyzers/RSA01 -name "RSA01-2025.04.04.*.tiq_spectrogram.npz" > filelist.txt
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/summed_spectrum$ python npz_addup.py --time-cut 0.14 filelist.txt
  157   Fri Apr 4 16:12:54 2025 JG, IDGeneralpleiades detectors moving
We started moving the pleiades detectors at 16:13 04-04-2025.

We have the inside pocket (GE01DD2IG) at 2mm. 
The outside pocket (GE01DD2AG) cannot be moved by the Device Control program, some problem with the tolerance (error message: outside of tolerance). Need to go in in a short break and check what is wrong.

We will partly scrape the beam.
  156   Fri Apr 4 16:12:14 2025 Team PLEIADESDetectorsInserting both PLEIADES detectors
We are inserting both PLEIADES detectors step-wise, one by one. Main beam should not be affected too long.
  155   Fri Apr 4 16:01:09 2025 ID, MC, KanikaGeneral186Hf running now + Lassie screenshots
Tuning is finished, 186Hf is running. Sharp peaks now.
  154   Fri Apr 4 14:47:29 2025 ID MG BJGeneralLassie screen shots
186Hf screen shots with better resolution
  153   Fri Apr 4 14:01:20 2025 MG, ID,NHGeneralScreen shot
Lassie screen shots 186Hf
  152   Fri Apr 4 11:48:37 2025 MG, NH, IDGeneralsetting change to 186Hf + Lassie screenshots
186Hf, 510MeV/u of 208Pb beam, ecooling not working 
  151   Fri Apr 4 11:44:31 2025 Ragan, Wolfram, Sergey, Zsolt, MagdaGeneral ESR setting change from 188Hf72+ to 186Hf72+
ESR setting is changed from 188Hf72+ to 186Hf72+. SIS-18 beam energy for this fragment is 510 MeV/u.Brho = 7.86166 Tm.
  150   Fri Apr 4 11:15:05 2025 Ragan, Wolfram, Sergey, ZsoltGeneralElectron Cooler
No additional HV. So, have to proceed without the cooler. 
Spare Power supply did not work either, we will not be able to use the cooler for the rest of the experiment
  149   Fri Apr 4 11:00:35 2025 Ragan, Wolfram, Sergey, ZsoltGeneralElectron Cooler
Electron cooler anode voltage needs a repair which might take 20-30 mins. If it takes longer, we'll proceed without a cooler curve measurement. 
  148   Fri Apr 4 10:36:40 2025 Ragan, Wolfram, Sergey, ZsoltGeneralESR setting change from 188Hf72+ to 186Hf72+
ESR setting is changed from 188Hf72+ to 186Hf72+. SIS-18 beam energy for the primary beam transmission check is 528 MeV/u.
  147   Fri Apr 4 09:45:02 2025 Ragan, Wolfram, SergeyGeneralElectron Cooler
Regina, Jan, and Markus are in the ESR to check the electron cooler.
  146   Fri Apr 4 09:26:11 2025 Nic, MagdaGeneralstop
STOP RSA for beam tuning
  145   Fri Apr 4 08:53:30 2025 Nic, Magda, Ragan, JanGeneralBeam Break
Intensity dropped a lot, ion source fix ongoing
ESR access for 5-10 mins to restart PLEIADES DAQ
FRS has also taken beam again, so ESR is sharing

08:55: ESR closed and takes beam again
  144   Fri Apr 4 07:51:58 2025 Nic, MagdaGeneralScreenshots
  143   Fri Apr 4 06:45:12 2025 zhang, zhouGeneralscreenshot