Entry  Tue Apr 1 12:58:27 2025, Jelena B, Siddharth, General, Lassie 2025-04-01_12-57-50-275_tcl1064.png
 
Entry  Tue Apr 1 11:47:14 2025, Jelena B, Siddharth, General, Lassie 2025-04-01_11-46-35-517_tcl1064.png  2025-04-01_11-46-35-517_tcl1064.png
 
Entry  Tue Apr 1 10:34:20 2025, Jelena B, Siddharth, General, Resolved issue with SIS18 2025-04-01_10-33-38-948_tcl1064.png
Beam is back with some fluctuations.
We did not have beam from 9:34 until 10:08, around 35 minutes. 
Entry  Tue Apr 1 10:03:56 2025, Jelena B, Siddharth, General, Technical issue with SIS18  2025-04-01_10-02-16-454_tcl1064.png
From HKR info: there is a technical issue with SIS18 and we will have no beam for next 25 minutes. 
Entry  Tue Apr 1 08:36:25 2025, Jelena B, Siddharth, General, Lassie 2025-04-01_08-37-32-155_tcl1064.png 2025-04-01_08-37-32-155_tcl1064.png
 
Entry  Tue Apr 1 06:53:51 2025, Jelena B,Siddharth, General, Lassie Monitor 2025-04-01_06-49-59-989_tcl1064.png
 
Entry  Tue Apr 1 06:31:46 2025, Michael, General, Lassie Monitor 2025-04-01_06-31-10-211_tcl1064.png 2025-04-01_06-31-10-211_tcl1064.png
 
Entry  Tue Apr 1 05:58:51 2025, Michael, General, Lassie Monitor 2025-04-01_05-58-09-122_tcl1064.png 2025-04-01_05-58-09-122_tcl1064.png
 
Entry  Tue Apr 1 05:29:45 2025, Michael, General, Lassie Monitor 2025-04-01_05-29-01-845_tcl1064.png 2025-04-01_05-29-01-845_tcl1064.png
 
Entry  Tue Apr 1 04:59:14 2025, Michael, General, Lassie Monitor 2025-04-01_04-58-31-351_tcl1064.png 2025-04-01_04-58-31-351_tcl1064.png
 
Entry  Tue Apr 1 04:27:10 2025, Michael, General, Lassie Monitor 2025-04-01_04-25-53-171_tcl1064.png 2025-04-01_04-25-53-171_tcl1064.png
 
Entry  Tue Apr 1 03:55:59 2025, Michael, General, Lassie Monitor 2025-04-01_03-55-21-183_tcl1064.png 2025-04-01_03-55-21-183_tcl1064.png
 
Entry  Tue Apr 1 03:52:56 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, good files 
all settings are done.
any files coming after this one is good:
Entry  Tue Apr 1 03:50:12 2025, Shahab, Yue, Carlo, Zac, Esther, Michael, DAQ, Tuners of the both cavities set 
410 MHz cavity resonance frequency tuned. motors both on 50 mm
245 MHz cavity resonance frequency tuned. motors both on 390 mm
Entry  Tue Apr 1 03:27:44 2025, Michael, General, Lassie Monitor 2025-04-01_03-22-05-395_tcl1064.png  2025-04-01_03-22-05-395_tcl1064.png
 
Entry  Tue Apr 1 02:55:06 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, new RSA recording IMG_4955.JPGIMG_4956.JPGIMG_4954.JPG
anything from RSA01-2025.04.01.02.54.25.976.tiq onwards is good data

recording parameters:
Entry  Tue Apr 1 02:37:28 2025, H. Weick, S. Litvinov, Accelerator, Isoc-setting +scrapers IMG_20250401_013626.jpgIMG_20250401_013636.jpgIMG_20250401_013646.jpgIMG_20250401_023358.jpg
First a setting with orbit bump for injection on central orbit was tried.
- quadrupoles tuned and scrapers optimized
Entry  Tue Apr 1 02:20:36 2025, ruijiu, Analysis, change back the frequency of 194Pb82 Screenshot_2025-04-01_02-20-09.png
frequency of 194Pb82+ at 211 408606000
frequency of 194Pb82+ at 126 244001000
Entry  Tue Apr 1 02:03:33 2025, ruijiu, Analysis, The frequency of 194Pb82+ has been changed from 408.522 MHz to 408.637 MHz Screenshot_2025-04-01_02-03-14.png
this is the new setting after we lost the old one.

Entry  Tue Apr 1 02:01:06 2025, Zac, Shahab, Ruijiu, Yuri, Sergey, Wolfram, Carlo, Michael, Accelerator, Settings lost 
Settings lost after the beam was lost. Trying to recover particle identification now that beam has returned.