Fri Apr 4 16:12:54 2025, JG, ID, General, pleiades detectors moving
|
We started moving the pleiades detectors at 16:13 04-04-2025.
We have the inside pocket (GE01DD2IG) at 2mm.
|
Tue Apr 8 21:56:37 2025, Shahab, Michael, Xinliang, DAQ, new settings
|
last file with old setting:
RSA01-2025.04.08.21.55.22.661.tiq
|
Fri Apr 4 18:38:52 2025, Dima, Zac, Sid, Kanika, Ragan, Shahab, Beatriz, DAQ, new file name and settings for 245 MHz 
|
new settings:
1.8 seconds recording on 245 MHz on RSA02
|
Tue Apr 1 02:55:06 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, new RSA recording  
|
anything from RSA01-2025.04.01.02.54.25.976.tiq onwards is good data
recording parameters:
|
Tue Apr 8 20:29:24 2025, Michael, Shahab, DAQ, new DAQ settings
|
NTCAP Started
RSAs started:
|
Mon Apr 7 03:25:41 2025, Siddharth, Dima , Collaboration, mesycontrol does not start GUI
|
mesycontrol process starts but shows no GUI at all.
Around 02:51 we wanted to record leakage currents for PLEIADES.
|
Mon Apr 7 15:14:54 2025, Oliver, Filip, General, lassie screenshots   
|
|
Fri Apr 4 18:24:31 2025, BJ KK, General, lassie screenshot  
|
|
Sun Apr 6 06:51:08 2025, Hongfu LI, Xing Xu, Gregor Kosir, General, lassie screen shot   
|
|
Mon Mar 31 23:34:58 2025, ruijiu, shahab, yuri, wolfram, sergey, Analysis, identificaton of 194Pb82+ 8x
|
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.03.31.22.18.16.965.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.4"
|
Tue Apr 1 03:52:56 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, good files
|
all settings are done.
any files coming after this one is good:
|
Tue Apr 1 15:38:50 2025, ruijiu chen, Analysis, frequency drift 
|
|
Wed Apr 2 12:58:15 2025, Ruijiu, Wolfram, Analysis, frequency drift  
|
|
Mon Mar 31 20:42:38 2025, H. Weick, S. Litvinov, Accelerator, fragment setting, E-SIS
|
~ 20:00 changed E-SIS to 524.0 MeV/u to get 194Pb at the Brho of the primary beam before (=7.2008 Tm).
which corresponds to gamma = 1.400 for 194Pb82+.
Before it was E-SIS = 480.5 MeV/u after Be-1839 mg/m^2 target Brho = 7.2014 Tm.
|
Mon Mar 31 16:05:48 2025, ruijiu, shahab, yuyue, zac, carlo, ersther, Analysis, check the trigger signal in the scaler data of NTCAP 
|
1. convert copy a tdms file into the folder:
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ cp /mnt/ntcap-data2/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-
48-51/0000216.sc.tdms ./
|
Mon Apr 7 18:58:04 2025, Shahab, DAQ, changed averaging in NPZ files
|
new analysis settings for NPZ files:
[analysis]
|
Tue Apr 1 02:20:36 2025, ruijiu, Analysis, change back the frequency of 194Pb82
|
frequency of 194Pb82+ at 211 408606000
frequency of 194Pb82+ at 126 244001000 |
Mon Apr 7 15:47:03 2025, Shahab, Taka, Ruijiu, DAQ, change NAS and restart both acquisitions
|
changed storage place to bank 1 of the NAS
restarted the NTCAP with new address
restarted Analyzers with new address
|
Tue Apr 1 22:05:24 2025, Ruijiu , Analysis, analysis result   
|
This is a preliminary result during 4:00-19:00 April 1st 2025.
I correct the frequency drift of 194Pb82+ ions injection by injection.
|
Mon Apr 7 16:07:42 2025, Shahab, General, all config files    
|
here are all TOML config files of the automatic scripts. |
|