Mon Mar 30 07:02:15 2020, tino, Runs, Second measurement with 206Pb81+ beam at I_cooler = 20 mA
|
I_cooler = 20 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 06:08 , run file: run0270.lmd (0268.lmd and 0269.lmd are garbage files)
file running: 0270.lmd
_______________________________________________________________________________
time: 07:00
I_cooler = -01 mA
ESR particles: 2.2E5
NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |
Sat Mar 28 16:12:25 2020, ruijiu, ragan, DAQ, enter ESR and turn on the HV crate.
|
|
Tue Feb 25 15:48:31 2020, ruijiu chen, DAQ, Important folders of e121 eperiments:
|
1. slow control:
1.1. program file:
litv-exp@ringpi:~/epics/mrcc_ioc/db $
1.2 user interface:
litv-exp@lxg1298:~/E121/scripts/GUIe121_new
2. mbs:
2.1 user interface
litv-exp@lxg1298:~/E121/scripts$ ./e121_gui.py
2.2 source
R4L-47 litv-exp > pwd
/esr/usr/litv-exp/2020_e121/
3. go4:
litv-exp@lxg1298:~/2019Munich-Det/Go4-Muenchen-3V785AH-1V830-simple$ go4
4. experimenal data:
litv-exp@lxg1298:/data.local1/E121 |
Tue Feb 25 15:49:58 2020, ruijiu chen, DAQ, changing scaling factor.
|
How to change scaling factor?
The parameters is in f_user.c file:
1. open the f_user.C with emacs :
R4L-47 litv-exp > emacs -nw f_user.c
2. change the parameters "MWPC_downscale".
#define MWPC_downscale 0 // reduction = 2**MWPC_downscale
3.compile the program.
4. restart mbs. |
Mon Mar 30 14:48:02 2020, ruijiu and Tino, Detectors, The leakcurrent of SiPad is over the setting limit.  
|
Because the
leakcurrent of
6 Sipads is
over the
setting limit,
the alarm of
HV module is
sounding.
Ruijiu
increase the
limit to 1500
uA. |
Mon Mar 30 15:03:58 2020, ruijiu Tino, Yuri, Lasoro, Nik and Uli, Detectors, the gas bottle is empty.
|
The gas bottle was empty. Tino replaced
the previous old bottle with 50 bar gas left.
Yuri is getting new gas bottles.
Yuri got a new gas bottle. We repalced
the the new gas bottle. There is 200
bar gas left now.
The old gas bottle with 50 bar gas
left was kept inside ESR.
The empty gas bottle was removed from
ESR.
The outlet volve was decreased by 30 degree.
Since the value is almost 0, we can not read the value of outlet volve. |
Sat Mar 28 15:07:40 2020, ruijiu, DAQ, start run
|
|
Sat Mar 28 15:19:23 2020, ruijiu, , start run e121_run_0236.lmd
|
store 206Pb81+ beam inside ESR and measure its halflife.
The HV of detector is off.
Start DAQ to record the ESR current in lmd file.
Nik is optimizing the gas jet target. So this file is still test run. |
Sun Mar 29 09:40:35 2020, ruijiu, DAQ, restart go4
|
go4 crush up.
the problem is
due to mbs.
restart mbs.
see an error.
restart again.
the mbs and go4
are working
working. |
Sun Mar 29 09:57:26 2020, ruijiu, Detectors, the HV of charged particle detector
|
MHV1 MHV2
ch1:1st Sipad 4th
Sipad
ch2:2nd Sipad 6th
Sipad
ch3:3rd Sipad DSSD
ch4:4th Sipad CsI |
Sun Mar 29 10:09:14 2020, ruijiu, , start run e121_run_0237.lmd
|
Sergey and Yuri are tuning Tl beam. The particle number in ers is about 1e4. I(SIS)=5e8
run stop: after few minutes (garbage data) |
Sun Mar 29 13:05:36 2020, ruijiu, DAQ, start ntcap
|
IQ_2020-03-29_13-05-
56
SC_2020-03-29_13-05-
56 |
Sun Mar 29 14:01:45 2020, ruijiu, , beam position on DSSD
|
move the detector 1cm
outside.from 60mm to
70mm.
left direction is
outside. right direction
is
inside(close to beam).
the spot is moving from
left to right. |
Sun Mar 29 14:29:13 2020, ruijiu, , e121_run_00240.lmd
|
s6 positon at 50mm. |
Sun Mar 29 18:41:31 2020, ruijiu, Analysis, Ratio between MPWC rate and DSSD rate
|
slit Ratio error
-1 18.64 0.4
-2 18.18 0.38
-3 20.85 0.5
-4 18.15 0.34
-5 17.44 0.31
-6 17.38 0.32
-7 17.82 0.32
-8 16.41 0.27
-9 18.51 0.37 |
Sun Mar 29 21:02:43 2020, ruijiu, Analysis, decay line of 205Tl beam 
|
decay line of 205Tl beam with Ar gas jet target on and S6 slit at -8mm
Ar gas density~1e12 atoms/cm2 |
Sun Mar 29 21:39:27 2020, ruijiu, Analysis, Ionization cross section and capture cross section for h-206Pb + Ar
|
Ionization cross section = 1320 barn.
Capture cross section = 557+137+44.5=735.5.
sigma_Ion/sigma_cap=1.79 |
Mon Mar 30 12:12:25 2020, ruijiu, General, Instruction of NTCAP for shift person
|
To start a new run with NTCap, we need to retart NTCAP.
1. Stop labview program.
2. Start labview program and start a new run. |
Mon Mar 30 13:40:57 2020, ruijiu, Detectors, HV of Inner detector
|
|
Mon Mar 30 13:41:20 2020, ruijiu, Detectors, HV of Inner detector
|
|