HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018 E0052_2025
  Bound beta decay experiment on Tl-205, Page 9 of 9  Not logged in ELOG logo
Entry  Tue Dec 15 09:25:41 2020, Jan, DAQ, SiCsIPhos signal/amplitude reconstruction amps.pdf
 
Entry  Mon Mar 29 16:31:09 2021, Pierre-Michel, DAQ, cross section Pb81onAr.png
(1.393*^-8 + 3.18*^-13 + 4.707*^-8)/4.707*^-8 = 1.29595
Entry  Wed Aug 25 15:13:41 2021, Jan, DAQ, SC13 clock frequency 
The frequency of the clock used as reference in scaler channel 13 has been measured precisely.
In contrast to what was expected (1.5MHz precisely), it is: 

f_ref =  1.5625(5) MHz
Entry  Thu Sep 13 11:32:17 2018, Jan Glorius, Collaboration, Proposal E121_Litvinov.pdfE121_Approval.pdf
Attached is the beam time proposal submitted and accepted by the G-PAC in 2017.
Entry  Sun Mar 29 18:41:31 2020, ruijiu, Analysis, Ratio between MPWC rate and DSSD rate ratio.png
slit	Ratio	error
-1	18.64	0.4
-2	18.18	0.38
-3	20.85	0.5
-4	18.15	0.34
-5	17.44	0.31
-6	17.38	0.32
-7	17.82	0.32
-8	16.41	0.27
-9	18.51	0.37
Entry  Sun Mar 29 21:02:43 2020, ruijiu, Analysis, decay line of 205Tl beam main_s6_neg8_202003292059.pngmain_s6_neg8_202003292059.root
decay line of 205Tl beam with Ar gas jet target on and S6 slit at -8mm
Ar gas density~1e12 atoms/cm2
Entry  Sun Mar 29 21:39:27 2020, ruijiu, Analysis, Ionization cross section and capture cross section for h-206Pb + Ar 202003292141.png
Ionization cross section = 1320 barn.
Capture cross section = 557+137+44.5=735.5.
sigma_Ion/sigma_cap=1.79
Entry  Sun Mar 29 23:48:12 2020, Jan, Analysis, run0251: E_spectra for CsISiPhos  14x
This is a collection of energy spectra of the CsISiPhos detectors from run0251 with primary beam.

There is no good spectra for n-side of Si-pad 1!
Entry  Mon Mar 30 16:37:53 2020, ruijiu, Analysis,  
 
Entry  Mon Mar 30 23:30:35 2020, Jan, Analysis, run251 - Si-pad performance & status 7x
Attached are plots for Si-pad 2 with hits from ionization of 206Pb81+ at the target.
The plots are representative for all Si-pads, the pattern is always the same!

y-axis: E n-side
x-axis: E p-side strip
condition: E_gate on peak in CsI

While strips 1, 2 and 7 look fine, strips 3 and 6 show already signs of degradation. 
For strips 4 and 5, it is clearly visible that something is wrong.
Those are the central strips, which probably see the most rate.

The same dataset was analyzed here: https://elog.gsi.de/esr/E121/62

This might be a hint to a radiation damage or to the fact that we operate at too low bias voltage (32 Volt).
Maybe it recovers if we increase bias to 60 Volt.
Entry  Tue Mar 31 15:30:43 2020, ruijiu, Analysis, The beam position on DSSD with different conditions on on the dEE spectrum 6x
I analyzed the first measurement with 206Pb81+ beam, run 250-267. 
Entry  Fri Apr 17 18:27:34 2020, ruijiu, Analysis, backup data IMG_20200417_162202.jpg
1.connect USB harddisk  to computer lxg1254 and  copy data to sever.

sync -rtmv --progress --checkSUD  /media/sdgl/data/ litv-exp@sbk0l9:/lustre/ap/litv-exp/2020-
04-14 e121_rchen/NTCAP/hd1

2020.05.02 08:06 copied 11.88 TB to server. 1.8TB rest on hard disk.
Entry  Wed Aug 5 17:19:16 2020, Rui-Jiu Chen, Analysis, Data structure DataStructure.pdf
 
Entry  Thu Nov 5 15:13:43 2020, Jan, Analysis, root script example e121_analysis.Ce121_mapped.he121_raw.h
Attached is an example root script/macro that shows how to use scripts for analysis.

Usage:
1. change INPUT and OUTPUT preprocessor variables in e121_analysis.c pointing to your desired input and output root-files.
2. open root and type:
  root [1] .L e121_analysis.C++
  root [2] run()
3. check plots popping up and output files

Hints:
in e121_analysis.C use
#include "e121_raw.h"
for the original channel names/mapping (e.g. ADC1_1,...)
and use
#include "e121_mapped.h"
for named channels (e.g. e_csi[0] or e_dssd_top)
Entry  Sat Mar 28 15:19:23 2020, ruijiu, , start run e121_run_0236.lmd 
store 206Pb81+ beam inside ESR and measure its halflife. 
The HV of detector is off.
Start DAQ to record the ESR current in lmd file.
Nik is optimizing the gas jet target. So this file is still test run.
Entry  Sun Mar 29 10:09:14 2020, ruijiu, , start run e121_run_0237.lmd 
Sergey and Yuri are tuning Tl beam. The particle number in ers is about 1e4. I(SIS)=5e8
run stop: after few minutes (garbage data)
Entry  Sun Mar 29 13:43:46 2020, , ,  5765BDDD-C10A-44AD-AF85-07134B06F34E.jpeg
 
Entry  Sun Mar 29 14:01:45 2020, ruijiu, , beam position on DSSD IMG_20200329_140003.jpg
move the detector 1cm 
outside.from 60mm to 
70mm.
left direction is 
outside. right direction 
is 
inside(close to beam).
the spot is moving from 
left to right.
Entry  Sun Mar 29 14:29:13 2020, ruijiu, , e121_run_00240.lmd 
s6 positon at 50mm.
Entry  Thu Apr 9 11:47:28 2020, ruijiu, , backup data IMG_20200409_113155.jpg
2020.4.8  12:00Started copying 
data。
2020.4.9    11:52 Copied 6.3TB 
data. The copy speed is 65-67MB/s.
2020.4.15 Bring the two USB hard disk to my office and connect them  to lxg1298 computer.
Send email 