| 530 | Fri May 28 22:54:38 2021 | Philipp, Benny | Runs | Run 0182 | 2021 | 
| No. of stacks: 10 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0182.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +2.0 mm
 
 run start:  22:54:11 28.05.2021
 run stop:   23:53:17 28.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 5   Hz
 Xray_ON_bdt:  ~ 120 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      6e8 (one shoot)
 ESR current at injection:  3e6 (stacked)
 ESR particles after decel.: 1e6
 Target ON density:          1.0e14
 | 
| 531 | Fri May 28 23:54:03 2021 | Philipp, Benny | Runs | Run 0183 | 2021 | 
| No. of stacks: 10 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0183.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +2.0 mm
 
 run start:  23:53:35 28.05.2021
 run stop:    00:52:43 29.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 5   Hz
 Xray_ON_bdt:  ~ 120 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.5e8 (one shoot)
 ESR current at injection:  3.3e6 (stacked)
 ESR particles after decel.: 2.2e5
 Target ON density:          1.0e14
 | 
| 532 | Sat May 29 00:53:43 2021 | Philipp, Benny | Runs | Run 0184 | 2021 | 
| No. of stacks: 10 00:52:43 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0184.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +2.0 mm
 
 run start:  00:53:10 29.05.2021
 run stop:    01:55:48 29.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 6   Hz
 Xray_ON_bdt:  ~ 140 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      6.5e8 (one shoot)
 ESR current at injection:  3.3e6 (stacked)
 ESR particles after decel.: 1e5
 Target ON density:          1.0e14
 
 Information: Problems with the accelerator, started at about 1:00, no new spills into the ESR until 1:15
 | 
| 533 | Sat May 29 01:56:21 2021 | Philipp, Benny | Runs | Run 0185 | 2021 | 
| No. of stacks: 10 00:52:43 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0185.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +2.0 mm
 
 run start:  01:55:56 29.05.2021
 run stop:    02:53:06 29.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 4   Hz
 Xray_ON_bdt:  ~ 120 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      5e8 (one shoot)
 ESR current at injection:  3e6 (stacked)
 ESR particles after decel.: 1.5e6
 Target ON density:          1.0e14
 | 
| 534 | Sat May 29 02:53:48 2021 | Philipp, Benny | Runs | Run 0186 | 2021 | 
| No. of stacks: 10 00:52:43 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0186.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +2.0 mm
 
 run start:  02:53:14 29.05.2021
 run stop:    03:54:35 29.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 5   Hz
 Xray_ON_bdt:  ~ 140 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      7e8 (one shoot)
 ESR current at injection:  3e6 (stacked)
 ESR particles after decel.: 1.5e6
 Target ON density:          1.0e14
 | 
| 535 | Sat May 29 03:55:10 2021 | Philipp, Benny | Runs | Run 0187 | 2021 | 
| No. of stacks: 10 00:52:43 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0187.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +2.0 mm
 
 run start:  03:54:41 29.05.2021
 run stop:    04:54:25 29.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 6   Hz
 Xray_ON_bdt:  ~ 150 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      8e8 (one shoot)
 ESR current at injection:  3.1e6 (stacked)
 ESR particles after decel.: 1.5e6
 Target ON density:          1.0e14
 | 
| 536 | Sat May 29 04:55:11 2021 | Philipp, Benny | Runs | Run 0188 | 2021 | 
| No. of stacks: 10 00:52:43 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0188.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +2.0 mm
 
 run start:  04:54:46 29.05.2021
 run stop:    05:54:27 29.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 8   Hz
 Xray_ON_bdt:  ~ 140 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      5e8 (one shoot)
 ESR current at injection:  3e6 (stacked)
 ESR particles after decel.: 1.3e6
 Target ON density:          1.0e14
 | 
| 537 | Sat May 29 05:55:01 2021 | Philipp, Benny | Runs | Run 0189 | 2021 | 
| No. of stacks: 10 00:52:43 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0189.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +2.0 mm
 
 run start:  05:54:34 29.05.2021
 run stop:   06:57:51 29.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 5   Hz
 Xray_ON_bdt:  ~ 120 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  380 nA
 
 
 SIS particles before:      2.4e9 (one shoot)
 ESR current at injection:  3.3e6 (stacked)
 ESR particles after decel.: 1.5e6
 Target ON density:          1.0e14
 | 
| 447 | Tue May 25 13:49:51 2021 | Oliver, Diego, Jan | General | No Beam | 2021 | 
| No beam from 13:49:00 until  | 
| 561 | Sun May 30 06:32:43 2021 | Oliver, Diego, Jan | Runs | Run 0210 | 2021 | 
| No. of stacks: 10 00:52:43 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0210.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +6.0 mm
 
 run start:  06:32:16 30.05.2021
 run stop:   07:12:04 30.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 0   Hz
 Xray_ON_bdt:  ~ 110 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  400 nA
 
 
 SIS particles before:      2.7e9 (one shoot)
 ESR current at injection:  2.7e6 (stacked)
 ESR particles after decel.: not measurable
 Target ON density:          8.0E13
 | 
| 562 | Sun May 30 07:26:14 2021 | Oliver, Diego, Jan | Runs | Run 0211 | 2021 | 
| No. of stacks: 10 00:52:43 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0211.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +6.0 mm
 
 run start:  07:25:54 30.05.2021
 run stop:   08:04:19 30.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 0   Hz
 Xray_ON_bdt:  ~ 110 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  400 nA
 
 
 SIS particles before:      2.7e9 (one shoot)
 ESR current at injection:  2.7e6 (stacked)
 ESR particles after decel.: not measurable
 Target ON density:          8.0E13
 | 
| 437 | Tue May 25 07:46:39 2021 | Oliver, Diego | Runs | Run 0111 | 2021 | 
| No. of stacks: 30 (before 20) length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0111.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 07:46:02 25.05.2021
 run stop:  08:51:14 25.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~0 Hz
 Xray_ON_bdt: 100 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  390 uA
 
 
 SIS particles before:      3.0e9
 ESR current at injection:  4.3e6 (stacked)
 ESR particles after decel.: 1.2e6 (more or less)
 Target ON density:          1.0e14
 | 
| 440 | Tue May 25 08:51:50 2021 | Oliver, Diego | Runs | Run 0112 - stopped for filling detectors | 2021 | 
| No. of stacks: 30 (before 20) length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0112.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 08:51:18 25.05.2021
 run stop:  09:00:40 25.05.2021 stopped for filling detectors
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~0 Hz
 Xray_ON_bdt: 140 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  390 uA
 
 
 SIS particles before:      3.5e9
 ESR current at injection:  6.3e6 (stacked)
 ESR particles after decel.: 1.5e6 (more or less)
 Target ON density:          1.0e14
 | 
| 441 | Tue May 25 09:11:13 2021 | Oliver, Diego | Runs | Run 0113 - stopped for ESR optimizations | 2021 | 
| DAQ node2 was on pause! 
 No. of stacks: 30 (before 20)
 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0113.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 09:10:39 25.05.2021
 run stop:  09:39:45 25.05.2021 stopped for ESR optimization
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~0 Hz
 Xray_ON_bdt: 140 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  390 uA
 
 
 SIS particles before:      3.3e9
 ESR current at injection:  6.0e6 (stacked)
 ESR particles after decel.: 1.5e6 (more or less)
 Target ON density:          1.0e14
 | 
| 442 | Tue May 25 09:53:04 2021 | Oliver, Diego | Runs | (No)Run 0114 | 2021 | 
| Run0114 was started after ESR optimization but immedieatly again stopped...
at 09:52:34 on 25.05.2021 | 
| 443 | Tue May 25 10:22:23 2021 | Oliver, Diego | Runs | Run 0115 - after ESR optimization | 2021 | 
| DAQ node2 was on pause! 
 No. of stacks: 30 (before 20)
 length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0115.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 10:21:12 25.05.2021
 run stop:  10:33:42 25.05.2021 stopped again for ESR opt.
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~0 Hz
 Xray_ON_bdt: 140 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  400 uA
 
 
 SIS particles before:      2.2e9
 ESR current at injection:  5.7e6 (stacked)
 ESR particles after decel.: 1.5e6 (more or less)
 Target ON density:          1.0e14
 | 
| 444 | Tue May 25 11:36:00 2021 | Oliver, Diego | Runs | Run 0116 - after ESR optimization | 2021 | 
| No. of stacks: 30 (before 20) length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0116.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 11:35:25 25.05.2021
 run stop:  12:35:27 25.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~0 Hz
 Xray_ON_bdt: 160 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  390 uA
 
 
 SIS particles before:      2.6e9
 ESR current at injection:  6.5e6 (stacked)
 ESR particles after decel.: 1.75e6 (more or less)
 Target ON density:          1.1e14
 | 
| 446 | Tue May 25 12:36:10 2021 | Oliver, Diego | Runs | Run 0117 | 2021 | 
| No. of stacks: 30 (before 20) length SC10: 3x 5.5s
 bump ge01sq2f (sc10): -20 mm (before -10 mm)
 
 open file : e127b_run0117.lmd
 
 beam: 118Te52+
 energy: 7 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
 
 run start: 12:35:28 25.05.2021
 run stop:  13:49:00 25.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:   ~0 Hz
 Xray_ON_bdt: 140 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  390 uA
 
 
 SIS particles before:      3.0e9
 ESR current at injection:  6.8e6 (stacked)
 ESR particles after decel.: 1.75e6 (more or less)
 Target ON density:          1.1e14
 | 
| 552 | Sat May 29 23:05:52 2021 | Oliver, Diego | General | No Beam | 2021 | 
| Due to a radioprotection issue in CaveA there is no beam. We wait for the radioprotection shift to arrive...
Beam back at 23:18 | 
| 553 | Sat May 29 23:18:43 2021 | Oliver, Diego | Runs | Run 0203 | 2021 | 
| No. of stacks: 10 00:52:43 length SC10: 2x 5.5s
 bump ge01sq2f (sc10): -20 mm
 bump target   (sc10): -12.8 mm
 
 open file : e127b_run0203.lmd
 
 beam: 118Te52+
 energy: 6 MeV/u
 cooler voltage:
 
 purpose:
 Fragment beam measurement (beating the record of rad. beam pg-measurement)
 
 Detector position (Si): -25 mm
 GE01DD1IG position (Scraper): +6.0 mm
 
 run start:  23:18:19 29.05.2021
 run stop:   00:18:53 30.05.2021
 _______________________________________________________________________________
 
 ON Rates
 Si_ON_bdt:    ~ 0   Hz
 Xray_ON_bdt:  ~ 0 Hz
 BaF_OR:     ---
 
 Si voltage:          100.0 V
 Si leakage current:  410 nA
 
 
 SIS particles before:      2.0-2.9e9 (one shoot)
 ESR current at injection:  1.8e6 (stacked)
 ESR particles after decel.: not measurable
 Target ON density:          8.0E13
 |